Supermicro SSE-F3548S/SSE-F3548SR Configuration User’s Guide
23
To provide multiple interfaces or
ranges, separate with a comma (,).
E.g.: int range fx 0/1-10, fx 0/20
If multiple interfaces are provided, the
next step will perform the particular
configuration on all these interfaces.
Step 3 description <string>
Configure the interface description
String
– alphanumeric characters of
length 1-64.
Step 4 End
Exits the configuration mode.
Step 5 show interface description
Displays the interface description
configuration.
Step 6 write startup-config
Optional step – saves this configuration
to be part of startup configuration.
The example below shows the commands used to configure interface description.
SMIS# configure terminal
SMIS(config)# interface Fx 0/22
SMIS(config-if)# description Server_Cluster_0100
SMIS(config-if)# end
SMIS
# sh int description
Interface Status Protocol Description
--------- ------ -------- -----------
Fx0/1 up down
Fx0/2 up down
Fx0/3 up down
Fx0/4 up down
Fx0/5 up down
Fx0/6 up down
Fx0/7 up down
Fx0/8 up down
Fx0/9 up down