Содержание SBI-7127R-S6

Страница 1: ...SBI 7127R S6 Blade Module User s Manual Revison 1 0 ...

Страница 2: ...resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated i...

Страница 3: ...eneral overview of safety precautions that should be followed when installing and servicing SBI 7127R S6 blade module Chapter 3 Setup and Installation Refer to this chapter for details on installing the SBI 7127R S6 blade module into the SuperBlade chassis Other sections cover the installation and placement of memory modules and the installation of hard disk drives into the blade module Chapter 4 ...

Страница 4: ...SBI 7427R T3 Blade Module User s Manual iv Notes ...

Страница 5: ...4 Power Disconnection Warning 2 5 Equipment Installation 2 6 Restricted Area 2 7 Battery Handling 2 9 Redundant Power Supplies 2 10 Backplane Voltage 2 11 Comply with Local and National Electrical Codes 2 12 Product Disposal 2 13 Hot Swap Fan Warning 2 14 Power Cable and AC Adapter 2 15 Chapter 3 Setup and Installation 3 1 3 1 Overview 3 1 3 2 Installing Blade Modules 3 1 Powering Up a Blade Unit ...

Страница 6: ...3 9 Configuring and Setting up RAID 3 15 Chapter 4 Blade Module Features 4 1 4 1 Control Panel 4 2 Power Button 4 3 KVM Button 4 3 LED Indicators 4 3 KVM Connector 4 3 4 2 Mainboard 4 4 Jumpers 4 6 CMOS Clear 4 6 4 3 Blade Unit Components 4 7 Memory Support 4 8 Hard Disk Drives 4 8 Chapter 5 BIOS 5 1 5 1 Introduction 5 1 System BIOS 5 1 How To Change the Configuration Data 5 1 Starting the Setup U...

Страница 7: ...vii 5 9 Security 5 16 5 10 Save Exit 5 17 Appendix A BIOS POST Codes A 1 A 1 BIOS POST Messages A 1 A 2 BIOS POST Codes A 3 Recoverable POST Errors A 4 Terminal POST Errors A 4 ...

Страница 8: ...SBI 7427R T3 Blade Module User s Manual viii Notes ...

Страница 9: ...ith the SuperBlade www supermicro com products superblade Note A complete list of safety warnings is provided on the Supermicro web site at http www supermicro com about policies safety_information cfm 1 2 Product Checklist of Typical Components Your blade module ships with its B9DR7 mainboard already installed in its chassis Memory hard disk drives and the CPU must all be installed by the user af...

Страница 10: ...600 1333 1066 800 MHz speed 32GB 16GB 8GB 4GB 2GB and 1GB size SDRAM memory Memory is interleaved which requires modules of the same size and speed to be installed in groups of two or three Please refer to the Supermicro web site for a list of supported memory www supermicro com products superblade The detailed specifications for a blade module will contain a link to a list of recommended memory s...

Страница 11: ...a single disk RAID1 Data Mirroring an identical data image from one drive is copied to another drive The second drive must be the same size or larger than the first drive Enhanced RAID 5 or RAID 10 Data Mirroring as RAID1 with data mirrored from one or more disks to one or more disks of a second larger size You can couple the disks from the source to create a virtual volume and use one or more dis...

Страница 12: ...SBI 7127R S6 Blade Module User s Manual 1 4 Figure 1 1 Full Rack of Blade Enclosures and Blade Servers ...

Страница 13: ...ddress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Asia Pacific Address Super Micro Computer Inc 4F No 232 1 Liancheng Rd Chung Ho 235 Taipei County Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 3...

Страница 14: ...SBI 7127R S6 Blade Module User s Manual 1 6 Notes ...

Страница 15: ...e Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning Definition Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing acci...

Страница 16: ...TRUCCIONES IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez conscient des dangers liés aux circuits électriques et familiarisez vous avec les procédures couramment utilisées pour éviter les accidents Pour prendre connaissance de...

Страница 17: ... dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES Installation Instructions Warning Read the installation instructions before connecting the system to the power source 設置手順書 システムを電源に接続する前に 設置手順書をお読み下さい 警告 将此系统连接电源前 请先阅读安装说明 警告 將系統與電源連接...

Страница 18: ...dass im Gebäude ein Kurzschluss bzw Überstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A beträgt Advertencia Este equipo utiliza el sistema de protección contra cortocircuitos o sobrecorrientes del edificio Asegúrese de que el dispositivo de protección no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les ...

Страница 19: ...m the power supply module s before accessing the chassis interior to install or remove system components 電源切断の警告 システムコンポーネントの取り付けまたは取り外しのために シャーシー内部にアクセ スするには システムの電源はすべてのソースから切断され 電源コードは電源モジュールから取り 外す必要があります 警告 在你打开机箱并安装或移除内部器件前 必须将系统完全断电 并移除电源线 警告 在您打開機殼安裝或移除內部元件前 必須將系統完全斷電 並移除電源線 Warnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein das von den Spg Verso...

Страница 20: ... Waarschuwing Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren of verwijderen van systeem onderdelen dient u alle spanningsbronnen en alle stroomkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment 機器の設置 トレーニングを受け認定された人だけが...

Страница 21: ... mag alleen worden geïnstalleerd vervangen of hersteld door geschoold en gekwalificeerd personeel Restricted Area Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security This warning does not apply to workstations アクセス制限区域 このユニットは アクセス制限区域に設置されることを想定しています アクセス制限...

Страница 22: ... d accès réservés L accès à une zone d accès réservé n est possible qu en utilisant un outil spécial un mécanisme de verrouillage et une clé ou tout autre moyen de sécurité 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen ve...

Страница 23: ...nutzten Batterien nach den Anweisungen des Herstellers Attention Danger d explosion si la pile n est pas remplacée correctement Ne la remplacer que par une pile de type semblable ou équivalent recommandée par le fabricant Jeter les piles usagées conformément aux instructions du fabricant Advertencia Existe peligro de explosión si la batería se reemplaza de manera incorrecta Reemplazar la batería e...

Страница 24: ...ニットは複数の電源装置が接続されている場合があります ユニットの電源を切るためには すべての接続を取り外さなければなりません 警告 此部件连接的电源可能不止一个 必须将所有电源断开才能停止给该部件供电 警告 此裝置連接的電源可能不只一個 必須切斷所有電源才能停止對該裝置的供電 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugeführt wird müssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga más de una conexión para fuentes de alimentación Para cortar ...

Страница 25: ...意ください 警告 当系统正在进行时 背板上有很危险的电压或能量 进行维修时务必小心 警告 當系統正在進行時 背板上有危險的電壓或能量 進行維修時務必小心 Warnung Wenn das System in Betrieb ist treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema está en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le système est en fonctionnement des tensio...

Страница 26: ...取り付けはその地方および国の電気規格に準拠する必要があります 警告 设备安装必须符合本地与本国电气法规 警告 設備安裝必須符合本地與本國電氣法規 Warnung Die Installation der Geräte muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L équipement doit être installé conformément aux normes électriques nationales et locales ﻫﻨﺎﻙ ﺧﻄﺮ ﻣﻦ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﺍﻟﺘﻴﺎﺭ ﻋﻠﻰ ﺍﻟﻤﻮﺟﻮﺩﺓ ﺃﻭﺍﻟ...

Страница 27: ...规章进行 警告 本產品的廢棄處理應根據所有國家的法律和規章進行 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et ou directives de respect de l environnement Renseignez vous...

Страница 28: ...動 小心不要將手指 螺絲起子和其他物品 太靠近風扇 Warnung Die Lüfter drehen sich u U noch wenn die Lüfterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de la...

Страница 29: ... fire Electrical Appliance and Material Safety Law prohibits the use of UL or CSA certified cables that have UL CSA shown on the code for any other electrical devices than products designated by Supermicro only 電源コードと AC アダプター 製品を設置する場合 提供または指定された接続ケーブル 電源コードと AC アダプ ターを使用下さい 他のケーブルやアダプタを使用すると故障や火災の原因になるこ とがあります 電気用品安全法は UL または CSA 認定のケーブル UL CSE マークが コードに表記 を Supermicro が指定する製品以外に使用することを禁止しています 警...

Страница 30: ...amente Attention Lors de l installation du produit utilisez les bables de connection fournis ou désigné L utilisation d autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie Appareils électroménagers et de loi sur la sécurité Matériel interdit l utilisation de UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques que l...

Страница 31: ...인증한 케이블 전선 위에 UL CSA 가 표시 들의 사용을 금지합니다 Waarschuwing Bij het installeren van het product gebruik de meegeleverde of aangewezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op de code voor andere elektr...

Страница 32: ...SBI 7127R SH Blade Module User s Manual 2 18 Notes ...

Страница 33: ... off independently from the rest of the blades installed in the same enclosure A blade unit may be powered up in two ways Press the power button on the blade unit Use IPMIView or the web browser based management utility to apply power using the CMM module Powering Down a Blade Unit A blade unit may be powered down in either of the following ways Press the power button on the blade unit Use IPMIVie...

Страница 34: ...Enclosure above 2 Depress the two buttons on the cover while pushing the cover toward the rear of the blade unit When it stops lift the cover off the blade unit 3 To replace the cover fit the six grooves in the cover into the studs in the sides of the blade then slide the cover toward the front of the blade to lock it into place Installing a Blade Unit into the Enclosure Make sure the cover of the...

Страница 35: ...3 3 Chapter 3 Setup and Installation Figure 3 1 Inserting a Blade into the Enclosure Figure 3 2 Locking the Blade into Position ...

Страница 36: ...g comes into contact with the thermal grease on its underside 5 Raise the lever of the processor socket up until the processor is released from the socket then lift the silver cover plate and remove the processor 6 Reapply plastic socket covers to the LGA2011 sockets to prevent pin damage Installing a Processor Caution This action should only be performed by a trained service technician Caution Wh...

Страница 37: ...ress the second load lever labeled Close 1st to release the load plate that covers the CPU socket from its locking position Figure 3 4 Figure 3 3 Open First Load Lever Figure 3 4 Close First Load Lever OPEN1st OPEN1st WARNING WARNING Press down on Load Lever labeled Open 1st OPEN1st OPEN1st WARNING WARNING OPEN1st OPEN1st WARNING WARNING OPEN1st OPEN1st WARNING WARNING Press down on Load the Lever...

Страница 38: ...the load plate Lift the load plate to open it completely Figure 3 5 4 Using your thumb and the index finger remove the WARNING plastic cap from the socket Figure 3 6 Figure 3 5 Opening the Load Plate Figure 3 6 Removing the Warning Plastic Cap OPEN1st OPEN1st WARNING WARNING WARNING WARNING Gently push down to pop the load plate open WARNING ...

Страница 39: ...ny pins of the socket to avoid damaging the CPU or the socket Caution You can only install the CPU inside the socket in one direction Make sure that the CPU is properly inserted into the CPU socket before closing the load plate If it doesn t close properly do not force it as it may damage your CPU Instead open the load plate again and double check that the CPU is aligned properly 7 With the CPU in...

Страница 40: ...ever labeled Open 1st second Figure 3 11 Use your thumb to gently push the load levers down to the lever locks Figure 3 9 Closing the Load Plate Figure 3 10 Locking the Close First Lever Figure 3 11 Locking the Open 1st Lever OPEN1st OPEN1st Push down and lock the level labeled Close 1st OPEN1st OPEN1st OPEN1st OPEN1st Push down and lock the lever labeled Open 1st Lever Lock ...

Страница 41: ...ame Super Micro authorized manufacturer due to compatibility issues See details below on supported memory and our web site www supermicro com products superblade for recommended memory Caution For all SBI 7427R series blades ONLY VLP Very low profile memory can be used Populating Memory Slots The mainboard of a SBI 7127R S6 blade module has sixteen 16 memory slots eight for each processor Both int...

Страница 42: ...ight Memory Slots for Interleaved Operation of DIMMs CPU1 CPU2 Channel A Channel B Channel C Channel D Channel E Channel F Channel G Channel H A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 4 X X X X 8 X X X X X X X X 12 X X X X X X X X X X X X 16 X X X X X X X X X X X X X X X X Figure 3 13 16 slot DIMM Numbering P1 DIMMB1 CPU1 CPU2 P1 DIMMB2 P1 DIMMA1 P1 DIMMA2 P1 DIMMC2 P1 DIMMC1 P1 DIMMD2 P1 D...

Страница 43: ...lots A1 and A2 Pay attention to the notch along the bottom of the module to prevent inserting the DIMM incorrectly see Figure 3 14 5 Gently press down on the DIMM until it snaps into place in the slot Repeat for all modules see Table 3 1 for installing DIMMs into the slots in the correct order 6 Replace the air shroud and the blade cover and install the blade module back into the enclosure 7 Power...

Страница 44: ...ases the drive carrier from the drive bay 2 Pull the release handle out about 45 degrees then use it to pull the drive carrier out To Install a hard drive use the following procedure Installing a Hard Drive 1 Remove a blank drive carrier from the blade see removal procedure above 2 Insert a drive into the carrier with the PCB side facing down and the connector end toward the rear of the carrier 3 ...

Страница 45: ...method of installing the OS is with an external USB CD ROM drive Take the following steps to install the OS to a blade module Caution Installing the OS from an external CD ROM drive may take several hours to complete 1 Connect an SUV cable Serial port USB port Video port cable to the KVM connector on the front of the blade module You will then need to attach a USB hub to the USB port on this cable...

Страница 46: ...d to it Once these conditions are met make sure the PXE server is running Then turn on the blade on which you wish to boot and or install the OS The BIOS in the blade will look at all bootable devices and finding none will connect to the PXE server to begin the boot install Installing via Virtual Media Drive Redirection You can install the OS via Virtual Media through either the IPMIview Java base...

Страница 47: ...keep tabs on the system and perform management activities Refer to the manuals on your SuperBlade CD ROM for further details on the various functions provided by these management programs 3 9 Configuring and Setting up RAID Each blade module that supports two or more hard drives may be used to create a RAID array The procedures for doing this vary depending upon the blade model chosen for your Sup...

Страница 48: ...SBI 7127R S6 Blade Module User s Manual 3 16 Notes ...

Страница 49: ...ture Description Processors Supports single or dual 2011 pin Socket R LGA 2011 E5 2600 series processors Memory Supports up to 512 GB of RDIMM and 128 GB of UDIMM DDR3 1600 1333 1066 800 MHz speed 32GB 16GB 8GB 4GB 2GB and 1GB size SDRAM memory in sixteen 16 240 pin DIMM sockets Storage Up to six hot plug 2 5 hot pluggable enterprise SATA SAS SSD drives Ports KVM port 1 SATA port 1 Features Onboar...

Страница 50: ...ns blade module on and off 2 KVM Button N A Initiates KVM function 3 Power LED Green Indicates power status On Orange Indicates power status Off with power cables plugged in 4 KVM UID LED Blue Indicates KVM being utilized on blade unit Flashing Blue Indicates UID activated on blade module 5 Network IB LED Flashing Green Indicates network activity over LAN Flashing Orange Indicates network activity...

Страница 51: ...nother blade disconnect the cable then reconnect it to the new blade See the Web based Management Utility User s Manual on your SuperBlade system CD ROM for further details on using the KVM function remotely Table 4 3 Blade Module LED Indicators LED State Description Power LED Green Power On Amber Standby Red Power Failurea a In the event of a power failure the N 1 Redundant Power Supply if includ...

Страница 52: ...6 blade unit is a proprietary design which is based on the Intel C602J chipset See Figure 4 4 for a block diagram of this chipset Figure 4 3 for a view of the B9DR7 mainboard and Figure 4 5 for an exploded view diagram of the blade unit Figure 4 3 B9DR7 Mainboard 1 2 4 3 7 6 9 8 10 3 3 3 6 5 ...

Страница 53: ...ectors for power and logic to backplane 7 Onboard SATA Port 8 Intel C602J Chipset 9 Onboard Battery 10 KVM Module QPI 1 DDR3 DIMM 2 DDR3 DIMM DDR3 DIMM DDR3 DIMM DDR3 DIMM 2 1 DDR3 DIMM C602 PATSBURG Chipset AT25321 LPC CPU Rear Socket 1 Processor SandyBridge USB Front CMM TOP 0 1 CMM BOT TPM HDR Internal 2 QPI DDR3 DIMM DDR3 DIMM 1 2 1 2 1 2 1 2 1 2 1 2 DMI x8 x4 VGA Front CMM TOP CMM BOT SH7757 ...

Страница 54: ...d will also clear any passwords JBT1 consists of two contact pads located near the BIOS chip Clearing CMOS 1 First power down the blade and remove it from the enclosure 2 Remove the blade cover to access the mainboard see Removing Replacing the Blade Cover on page 3 2 for further details Short the CMOS pads with a metal object such as a small screwdriver 3 Replace the cover install the blade back ...

Страница 55: ...nts Figure 4 5 Exploded View of a SBI 7127R S6 Blade Module Table 4 5 Main Components of a SBI 7127R S6 Blade Module Item Description 1 Blade Unit Module 2 2 5 Hard Drives 3 DIMMs system memory 4 CPU Heatsinks 2 5 Top Cover 6 Air Shroud 2 2 3 5 6 2 1 4 3 3 3 4 ...

Страница 56: ... unit accommodates up to six 2 5 SATA SAS SSD hard disk drives which are mounted in drive trays The drives can be hot swapped and removed or replaced without powering down the blade unit they reside in The six drives can be used to set up a RAID array RAID 0 1 5 and 10 Windows RAID 0 1 and 10 Linux RAID 0 1 5 6 10 and 50 SAS or JBOD These drives use a yellow color for the Blade HDD active LED See ...

Страница 57: ...ittle electrical power When the blade unit is turned off a backup battery provides power to the BIOS flash chip enabling it to retain system parameters Each time the blade is powered on it is configured with the values stored in the BIOS ROM by the system BIOS which gains control at boot up How To Change the Configuration Data The CMOS information that determines the system parameters may be chang...

Страница 58: ...included with the system 1 Copy the contents of the zip file to a bootable USB pen drive 2 Connect the KVM dongle CBL 0218L to the KVM connector at the front of the blade you will be flashing the BIOS to 3 Connect your bootable USB pen drive to one of the two USB slots on the KVM dongle 4 Boot to the USB pen drive and go to the directory where you saved the contents of the zip file 5 Type flash fi...

Страница 59: ... ROM file name such as B8DTE142 rom for example in the command 5 3 Running Setup Note Default settings are in bold text unless otherwise noted The BIOS setup options described in this section are selected by choosing the appropriate text from the MAIN BIOS SETUP screen All displayed text is described in this section although the screen display is often all you need to understand how to set the opt...

Страница 60: ...press the ENTER key to access the submenu Menu options found in the MAIN BIOS SETUP menu are described in Table 5 1 Figure 5 1 BIOS Setup Screen Table 5 1 Main BIOS Setup Menu Options Menu Option Description System Date Using the arrow keys highlight the month day and year fields and enter the correct data for the system date Press the Enter key to save the data System Time To set the system date ...

Страница 61: ...Super IO Configuration SH7757 See Table 5 8 for a description of BIOS setup menu options in this sub menu Serial Port Console Redirection See Table 5 9 for a description of BIOS setup menu options in this sub menu ACPI Settings See Table 5 10 for a description of BIOS setup menu options in this sub menu ME Subsystem See Table 5 11 for a description of BIOS setup menu options in this sub menu Table...

Страница 62: ...en Disabled only one thread per enabled core is enabled Active Processor Cores This setting selects the number of cores to enable in each processor package Options include All 1 2 4 and 6 Limit CPUID Maximum This setting is disabled for Windows XP Options include Enabled or Disabled Execute Disable Bit XD can prevent certain classes of malicious buffer overflow attacks when combined with a support...

Страница 63: ...pport Enabled CPU C3 Report Disabled CPU C6 Report Enabled CPU C7 Report Enabled Package C state Limit C6 Energy Performance Long Duration Power Limit Long Duration Maintained Short Duration Power Limit Energy Performance This option allows you to optimize between power and energy savings Windows 2008 and later OSes overides this value according to its power plan Options include Performance Balanc...

Страница 64: ...s setting allows you to select QPI Link Speed as being either Fast or Slow mode QPI Link Frequency Select This setting allows you to select the QPI link frequency Options include Auto 6 4 GT s 7 2 GT s or 8 0 GT s DIMM Configuration This submenu displays static Memory Configuration information Current Memory Mode Current Memory Speed Mirroring and Sparing DIMM Information and other option settings...

Страница 65: ...acy USB Support This setting allows you to enable the use of Legacy USB devices If this option is set to Auto legacy USB support will be automatically enabled if a legacy USB device is installed on the mainboard and disabled if no USB devices are connected The options include Disabled Enabled and Auto Port 60 64 Emulation This setting Enables or Disables I O port 60h 64h emulation support This sho...

Страница 66: ...tes 512 Bytes 1024 Bytes 2048 Bytes or 4096 Bytes ASPM Support This sets the ASPM Level for your system Options include Disabled disables ASPM Auto lets BIOS auto configure or Force L0s force all links to L0s state Onboard LAN Option ROM Select This setting allows you to select the onboard LAN option ROM to be either PXE or iSCSI Note If iSCSI is selected LAN1 Option ROM select will cover all othe...

Страница 67: ...rial port transmission speed which must be matched on the other side Long or noisy lines may require lower speeds Options include 9600 19200 38400 57600 and 115200 Data Bits This sets the number of data bits as either 7 or 8 Parity A parity bit can be sent with the data bits to detect some transmission errors Options include None no parity bit Even parity bit is 0 if the number of 1 s in the data ...

Страница 68: ...t Even parity bit is 0 if the number of 1 s in the data bits is even Odd parity bit is 0 if the number of 1 s in the data bits is odd Mark parity bit is always 1 or Space parity bit is always 0 The Mark and Space Parity do not allow for error detection Stop Bits Stop bits indicate the end of a serial data packet a start bit indicates the beginning The standard setting is 1 stop bit Communications ...

Страница 69: ... Second This setting selects the serial port transmission speed which must be matched on the other side Long or noisy lines may require lower speeds Options include 9600 19200 57600 and 115200 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start sig...

Страница 70: ...o Enable or disable PCI error logging for your system When Log is Full Use this setting to choose options for reactions to a full SMBIOS Event Log Options include Do Nothing and Erase Immediately Log System Boot Event Use this setting to choose the option to Enable or Disable logging of system boot events MECI This setting Multiple Event Count Increment is used to select the number of occurrences ...

Страница 71: ...o choose options for reactions to a full SEL Options include Do Nothing and Erase Immediately Log EFI Status Codes Use this setting to Enable or Disable logging of EFI status codes log only error codes or only progress codes BMC Network Configuration Use this submenu to configure BMC network parameters BMC Network Configuration Information The submenu contains static display information for the St...

Страница 72: ...equence of priority for the boot device such as hard disk drives USB devices CD ROM drives Network drives and so on The menu options are for 1st Boot Device 2nd Boot Device and 3rd Boot device 4th Boot Device and so on Each numbered boot device can be set to a specific device installed in your system or to Disabled NOTE A device enclosed in parenthesis has been disabled in the corresponding type m...

Страница 73: ...oot and implement the changes you have made to the BIOS Setup Save Changes Highlight this item and hit ENTER to save changes done so far to any of the setup options Discard Changes Highlight this item and hit ENTER to discard cancel any changes you made You will remain in the Setup utility Restore Defaults Highlight this item and hit ENTER to load the default settings for all items in the BIOS Set...

Страница 74: ...SBI 7127R S6 Blade Module User s Manual 5 18 Notes ...

Страница 75: ...64k block at which the error was detected System RAM Failed at offset nnnn System RAM failed at offset nnnn of in the 64k block at which the error was detected Extended RAM Failed at offset nnnn Extended memory not working or not configured properly at offset nnnn System battery is dead Replace and run SETUP The CMOS clock battery indicator shows the battery is dead Replace the battery and run Set...

Страница 76: ...e On older boards check the cache jumpers You may have to replace the cache See your dealer A disabled cache slows system performance considerably CPU ID CPU socket number for Multi Processor error EISA CMOS not writeable ServerBIOS2 test error Cannot write to EISA CMOS DMA Test Failed ServerBIOS2 test error Cannot write to extended DMA Direct Memory Access registers Software NMI Failed ServerBIOS...

Страница 77: ...lays Parity is a method for checking errors in binary data A parity error indicates that some data has been corrupted Parity Check 2 nnnn Parity error found in the I O bus BIOS attempts to locate the address and display it on the screen If it cannot locate the address it displays Press F1 to resume F2 to Setup F3 for previous Displayed after any recoverable error message Press F1 to start the boot...

Страница 78: ...al POST Errors Post Code Description 02h Verify Real Mode 03h Disable Non Maskable Interrupt NMI 04h Get CPU type 06h Initialize system hardware 07h Disable shadow and execute code from the ROM 08h Initialize chipset with initial POST values 09h Set IN POST flag 0Ah Initialize CPU registers 0Bh Enable CPU cache 0Ch Initialize caches to initial POST values 0Eh Initialize I O component 0Fh Initializ...

Страница 79: ...es 41h Initialize extended memory for RomPilot 42h Initialize interrupt vectors 45h POST device initialization 46h 2 1 2 3 Check ROM copyright notice 47h Initialize I20 support 48h Check video configuration against CMOS 49h Initialize PCI bus and devices 4Ah Initialize all video adapters in system 4Bh QuietBoot start optional 4Ch Shadow video BIOS ROM 4Eh Display BIOS copyright notice 4Fh Initiali...

Страница 80: ...tialize Intelligent System Monitoring 7Eh Initialize coprocessor if present 80h Disable onboard Super I O ports and IRQs 81h Late POST device initialization 82h Detect and install external RS232 ports 83h Configure non MCD IDE controllers 84h Detect and install external parallel ports 85h Initialize PC compatible PnP ISA devices 86h Re initialize onboard I O ports 87h Configure Motherboard Configu...

Страница 81: ... Erase F2 prompt AAh Scan for F2 key stroke ACh Enter SETUP AEh Clear Boot flag B0h Check for errors B1h Inform RomPilot about the end of POST B2h POST done prepare to boot operating system B4h 1 One short beep before boot B5h Terminate QuietBoot optional B6h Check password optional B7h Initialize ACPI BIOS B9h Prepare Boot BAh Initialize SMBIOS BBh Initialize PnP Option ROMs BCh Clear parity chec...

Страница 82: ...memory for PCMCIA CEh Initialize digitizer and display message D2h Unknown interrupt Table A 3 Boot Block Flash ROM Terminal POST Errors Post Code Description E0h Initialize the chipset E1h Initialize the bridge E2h Initialize the CPU E3h Initialize system timer E4h Initialize system I O E5h Check force recovery boot E6h Checksum BIOS ROM E7h Go to BIOS E8h Set Huge Segment E9h Initialize Multi Pr...

Страница 83: ...t have failed in the lower 16 bits The BIOS also sends the bitmap to the port 80 LED display It first displays the checkpoint code followed by a delay the high order byte another delay and then the low order byte of the error It repeats this sequence continuously F2h Initialize video F3h Initialize System Management Manager F4h Output one beep F5h Clear Huge Segment F6h Boot to Mini DOS F7h Boot t...

Страница 84: ...SBI 7427R S3 T3 Blade Module User s Manual A 10 Notes ...

Страница 85: ...pected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions lit...

Страница 86: ...SBI 7127R S6 Blade Module User s Manual 0 2 ...