17
Chapter 5: BIOS
Table 5-13. Event Logs Menu
Menu Option
Description
Change SMBIOS Event
Log Settings
Use this submenu to change the SMBIOS Event Log configuration.
SMBIOS Event Log
Change this item to enable or disable all features of the SMBIOS Event
Logging during system boot. The options are
Enabled
and Disabled.
Runtime Error Logging
Support
Use this setting to enable/disable the system error logging for events that
occur during runtime. The options are
Enabled
and Disabled.
Memory Corrected Error
Enabling
Use this setting to enable/disable the runtime event for memory
correctable errors. The options are
Enabled
and Disabled.
Memory Corr. Error
Threshold
This setting allows you to set the Spare Error/Memory Correctable
Threshold (1 ~ 32767) prior to the event assertion. The value for this
number field can be set using your keyboard’s number keys.
PCI-Ex Error Enable
This setting allows you to enable/disable the runtime event for PCI Express
errors. Options are either
No
or Yes.
Erase Event Log
If No is selected, data stored in the event log will not be erased. Select Yes,
Next Reset, data in the event log will be erased upon next system reboot.
Select Yes, Every Reset, data in the event log will be erased upon every
system reboot. The options are
No
, Yes, Next reset, and Yes, Every reset.
When Log is Full
Select Erase Immediately for all messages to be automatically erased from
the event log when the event log memory is full. The options are
Do
Nothing
and Erase Immediately.
Log System Boot Event
This option toggles the System Boot Event logging to enabled or disabled.
The options are
Disabled
and Enabled.
MECI
The Multiple Event Count Increment (MECI) counter counts the number of
occurences that a duplicate event must happen before the MECI counter is
incremented. This is a numeric value. The default value is
1
.
METW
The Multiple Event Time Window (METW) defines number of minutes must
pass between duplicate log events before MECI is incremented. This is in
minutes, from 0 to 99. The default value is
60
.
View SMBIOS Event Log Use this submenu to view the SMBIOS Event Log records.
Содержание MBI-6219G-T
Страница 1: ...MBI 6219G T MicroBlade Module User s Manual Revison 1 0c...
Страница 4: ...MBI 6219G T MicroBlade Module User s Manual iv...
Страница 8: ...MBI 6219G T MicroBlade Module User s Manual viii...
Страница 25: ...2 13 Chapter 2 Standardized Warning Statements...
Страница 30: ...MBI 6219G T MicroBlade Module User s Manual 2 18 UL CSA Supermicro UL CSA...
Страница 32: ...MBI 6219G T MicroBlade Module User s Manual 2 20...
Страница 74: ...MBI 6219G T MicroBlade Module User s Manual 24...