USER’S MANUAL 

Revision 1.0a

FatTwin

®

F619P2-FT

F619P3-FT

Содержание FatTwin F619P2-FT

Страница 1: ...USER S MANUAL Revision 1 0a FatTwin F619P2 FT F619P3 FT...

Страница 2: ...a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful...

Страница 3: ...ls Product drivers and utilities https www supermicro com wdl driver Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our supp...

Страница 4: ...Quick Reference Table 16 Chapter 2 Server Installation 2 1 Overview 18 2 2 Preparing for Setup 18 Choosing a Setup Location 18 Rack Precautions 18 Server Precautions 19 Rack Mounting Considerations 19...

Страница 5: ...ion Cards 34 Assembling the PCI E Slot Bracket Assembly 35 Installing Air Shrouds 37 Air Shrouds 37 Removing and Installing System Fans 38 Removing and Installing External System Fans 38 Replacing the...

Страница 6: ...54 4 2 Headers and Connectors 55 4 3 Front I O Ports 58 4 4 Jumpers 61 Explanation of Jumpers 61 4 5 LED Indicators 62 Chapter 5 Software 5 1 Microsoft Windows OS Installation 64 5 2 Driver Installati...

Страница 7: ...7 Appendix C System Specifications Appendix D UEFI BIOS Recovery Appendix E BSMI Safety Warnings...

Страница 8: ...B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma superm...

Страница 9: ...8 F418IF3 mylar air shrouds 2 pcs MCP 310 41812 0B or MCP 310 41813 0B 1 1U redundant power supplies PWS 2K20A 1R 2200 Watt or PWS 2K04A 1R 2000 Watt 4 Fat twin F418 F424 static rail set support 28 33...

Страница 10: ...wappable unit that may be removed from the chassis The nodes are connected to the server backplane by means of an adapter card Note A guide pin is located between the upper and lower nodes on the inne...

Страница 11: ...VDIMM DDR4 288 pin ECC memory of 2933 2666 2400 2133 MHz in 12 slots Chipset C621 chipset Expansion Slots The X11DPFF SN motherboard has the following expansion slots available One PCI E 3 0 x16 slot...

Страница 12: ...built in LED which will turn green when the power is on 2 UID LED When used with a UID compatible serverboard the UID indicator is used to turn on or off the blue light function of the LED This is bui...

Страница 13: ...has two bays in the front for low profile expansion cards See chapter 3 for details on the expansion cards 3 SIOM module See Chapter 4 for details on the SIOM modules Figure 1 2 Chassis Front View 1...

Страница 14: ...power supplies 2 Rear Fan The chassis has eight rear fans for cooling These are hot swappable and can be replaced without powering down the system Figure 1 3 Chassis Rear View Rear Features The illus...

Страница 15: ...JPW3 JPW2 JPW1 J31 J30 LED3 M 2 HC1 M 2 HC0 JIPMILAN JUSB1 UID VGA COM1 BIOS LEDM1 HDD_LED1 FAILURE_LED1 CPU1 SLOT1 PCI E 3 0 x16 JPCIE4 UID_LED1 USB0 1 3 0 TPM PORT80 JUIDB1 PWR IPMI_LAN X11DPFF SN...

Страница 16: ...PB MISC 8 pin auxiliary power connector for ADP via a cable connected to a power adaptor card JRK1 NVMe RAID Key header JSDCARD1 BMC SD card header M 2 HC0 M 2 HC1 J30 J31 PCI E SATA hybrid M 2 slots...

Страница 17: ...DDR4 2133 2666 1 1 2 3 2 3 DMI3 DMI3 P2 P2 USB SPI SPI VGA RJ45 COM DDR4 BMC Boot Flash RMII NCSI RGMII VGA COM PORT Bus S W SYSTEM POWER PCI E X16 PCI E X8 SIOM X16 PCI E X16 G3 PCI E X16 G3 PCI E X1...

Страница 18: ...Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where h...

Страница 19: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...

Страница 20: ...ern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connections other than the...

Страница 21: ...t designed for installation into a Telco post style rack unit Stability Hazard The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before you slide the unit out for...

Страница 22: ...l assemblies in the rack mounting kit Each assembly consists of two sections A front section which secures to the front post of the rack and a rear section which adjusts in length and secures to the r...

Страница 23: ...rail with the slots on the front post of the rack Secure the front of the outer rail to the rack with two screws 3 Pull out the rear section of the outer rail adjusting the length until it fits withi...

Страница 24: ...Installing into a Rack Chassis Installation Installing the Chassis into a Rack 1 Confirm that the rails are correctly installed on the rack 2 Align the bottom of the chassis with the bottom of the ra...

Страница 25: ...on 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installing non hot swap components or when replacing a n...

Страница 26: ...is separately Installing and Removing the Node Drawers The F418IF3 chassis contains eight individual motherboards in separate node drawers Figure 3 1 Each motherboard node controls a set of two intern...

Страница 27: ...Node 1 Grasp the node by the handles on both sides of the front of the node 2 Press down on the left handle to disengage the latch 3 While holding down the left handle carefully pull the node forward...

Страница 28: ...n Figure 3 3 Figure 3 3 Front and Rear of the F418IF3 R2K20BP Node Front of the Node Rear of the Node F418IF3 R2K20BP Node Layout The specifications for the F418IF3 R2K20BP nodes are shown in the tabl...

Страница 29: ...the chassis the hard drives associated with that node will power down as well Refer to the charts below and on the following pages for your specific chassis configuration Installing and Removing 2 5 H...

Страница 30: ...e Node 1 7 Figure 3 5 Installing a Hard Drive in the Drive Carrier 5 5 Lift the hard drive up and out of the tray 6 Install a replacement drive into the hard drive tray and secure it to the tray with...

Страница 31: ...t supported in VMD mode Red On for five seconds then off Power on for drive with RSTe support Red Blinking at 4 Hz Identify drive with RSTe support Green Solid On Safe to remove NVMe device not suppor...

Страница 32: ...atus LED indicator flashes red then turns off The Activity LED turns blue Checking the Temperature of an NVMe Drive There are two ways to check using IPMI Checking a Drive IPMI Server Health NVMe SSD...

Страница 33: ...er and separate the drive from the tray There will be small clips that hold the drive into the lower side of the tray so remove the drive from the higher side of the tray first and then separate the d...

Страница 34: ...eight nodes in the chassis has space for two low profile expansion cards mounted in the front of the node The following instructions are for chassis nodes in which the expansion cards are mounted in t...

Страница 35: ...er card which in turn plugs into the motherboard Assembling the PCI E Slot Bracket Assembly 1 Remove the node from the chassis and remove the cover from the node as described previously in this sectio...

Страница 36: ...t the riser card into the appropriate slot on the motherboard 6 Simultaneously insert the expansion card into the riser card while sliding the expansion card bracket into the open PCI E slot Figure 3...

Страница 37: ...e Installing an Air Shroud 1 Remove the node from the chassis and remove the cover from the node as described previously in this section 2 Make sure that the motherboard and all components are properl...

Страница 38: ...y simply removing them from the rear without powering down the system Removing a Rear Exhaust Fan 1 Determine which fan has failed 2 Press the release tabs on the fan and pull it away from rear of the...

Страница 39: ...upplies In the unlikely event that the power supply unit needs to be replaced a power supply can be removed without powering down the system Replacement units can be ordered directly from Supermicro S...

Страница 40: ...he processor into the CPU socket before you install the CPU heatsink If you buy a CPU separately make sure that you use an Intel certified multi directional heatsink only Make sure to install the moth...

Страница 41: ...41xx 31xx and 82xx 62xx 52xx 42xx 32xx processor 2 CPU heatsink carrier 3 dust cover and 4 CPU socket 3 Dust Cover 4 CPU Socket 1 The 81xx 61xx 51xx 41xx 31xx and 82xx 62xx 52xx 42xx 32xx processor P...

Страница 42: ...cessor heatsink module PHM contains 1 a passive heatsink 2 a CPU heatsink carrier and 3 The 81xx 61xx 51xx 41xx 31xx and 82xx 62xx 52xx 42xx 32xx processor 1 Passive Heatsink 2 CPU Heatsink Carrier 3...

Страница 43: ...ocket and 4 a back plate These components are pre installed on the motherboard before shipping Processor Socket Assembly W A R N I N G Socket Cover LGA3647 Socket Socket Pins Removing the Dust Cover f...

Страница 44: ...Align Pin 1 Notch A Notch B and Notch C on the CPU with the corresponding notches on the carrier Once they are aligned carefully insert the CPU into the carrier until you hear a click Once the CPU is...

Страница 45: ...e a CPU carrier assembly please follow the steps below to mount the assembly onto the heatsink to create the Processor Heatsink Module PHM 1 Place the heatsink upside down with the thermal grease faci...

Страница 46: ...it through the corresponding mounting holes on the socket The PHM will only fit one way If it does not fit correctly remove it and try again 3 Using a T30 size star driver bit tighten eight screws int...

Страница 47: ...erclockwise to loosen it from the socket starting with screw marked 4 in the sequence of 4 3 2 1 2 After all eight screws are removed wiggle the PHM gently and pull up to remove it from the socket Not...

Страница 48: ...mory module by its edges only Put the memory modules into the antistatic bags when not in use Check the Supermicro website for recommended memory modules Introduction to Intel Optane DC Persistent Mem...

Страница 49: ...M Density One DIMM per Channel One DIMM per Channel Two DIMMs per Channel 4 Gb 8 Gb 16 Gb 1 2 Volts 1 2 Volts 1 2 Volts RDIMM SRx4 4 GB 8 GB 16 GB 2933 2933 2933 SRx8 8 GB 16 GB 32 GB DRx8 8 GB 16 GB...

Страница 50: ...MMs CPU1 P1 DIMMA1 P1 DIMMD1 1 CPU 3 DIMMs CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 1 CPU 4 DIMMs CPU1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMME1 1 CPU 5 DIMMs CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 D...

Страница 51: ...between 1 4 and 1 16 Excessive capacity for FM can be used for AD NM Near Memory FM Far Memory For each individual population rearrangements between channels are allowed as long as the resulting popul...

Страница 52: ...nto the slot until the module snaps into place 6 Press the release tabs to the lock positions to secure the DIMM module into the slot Release Tabs Notches Insert the DIMM module into the memory slot X...

Страница 53: ...with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a damaged battery may release haz...

Страница 54: ...s Two 8 pin 12V power connectors located at JPW1 JPW2 are used to provide main power to your system via power adaptor cards Connect appropriate power cables to JPW1 JPW2 and the power adaptor cards to...

Страница 55: ...pin HDD power connectors located at HDD_PWR1 2 provide power to HDD devices Connect appropriate power cables to use HDD power connectors See the table below for pin definitions 8 pin Power HDD_PWR1 2...

Страница 56: ...Me SDD Intel RAID Key Pin Definitions Pin Definition 1 Ground 2 3 3V Standby 3 Ground 4 PCH RAID Key 4 pin BMC External I2 C Header A System Management Bus header for IPMI 2 0 is located at JIPMB1 Con...

Страница 57: ...ed spatial efficiency The M 2 sockets located on the motherboard support PCI E 3 0 X4 32 Gb s SATA SSD cards in the 2260 2280 and 22110 form factors A Holder B Holder Mount C Card Holder Mount Turn 90...

Страница 58: ...s on the front of the motherboard Figure 4 1 Front Panel I O Port Locations and Definitions Front Panel I O Ports No Description No Description 1 SIOM Super I O Module Slot 5 UID Unit Identifier 2 VGA...

Страница 59: ...ndicator section below for LAN LED information Unit Identifier Switch UID LED Indicator A Unit Identifier UID switch located on the front panel and the UID LED UIDLED1 located next to the UID switch o...

Страница 60: ...node s front This SIOM slot supports PCI E 3 0 x16 SIOM cards Connect your SIOM cards into the SIOM slot with approved and qualified for FatTwin SIOM cards indicated on the SIOM Networking AOC Compat...

Страница 61: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...

Страница 62: ...tion hangs Close pins 2 3 to generate a non maskable interrupt signal for the application that hangs Watch Dog must also be enabled in BIOS The default setting is Reset Note When Watch Dog is enabled...

Страница 63: ...Please check your system to resolve the situation Failure LED Indicator LED LED State Definition Failure_LED1 On Red Overheating and or Fan Failure CPLD Heartbeat LED When the CPLD Heartbeat LED loca...

Страница 64: ...at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash...

Страница 65: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...

Страница 66: ...ferred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash d...

Страница 67: ...nitoring needs With SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Managemen...

Страница 68: ...such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cann...

Страница 69: ...System Date or System Time using the arrow keys on the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in Day MM DD YYYY format The time is entered in HH M...

Страница 70: ...ser s Manual CPLD Version This item displays the version of the CPLD Complex Programmable Logical Device used in the system Memory Information Total Memory This item displays the total size of memory...

Страница 71: ...OS timing setting may cause the system to malfunction When this occurs restore the setting to the manufacture default settings Boot Feature Quiet Boot Use this feature to select the screen between dis...

Страница 72: ...will not capture Interrupt 19 immediately to allow the drives attached to these adaptors to function as bootable devices at bootup The options are Immediate and Postponed Re try Boot When EFI Expansib...

Страница 73: ...sing and holding the power button for 4 seconds or longer Select Instant Off to instantly power off the system as soon as the user presses the power button The options are 4 Seconds Override and Insta...

Страница 74: ...able PPIN Control Select Unlock Enable to use the Protected Processor Inventory Number PPIN in the system The options are Unlock Enable and Unlock Disable Hardware Prefetcher Available when supported...

Страница 75: ...ving mode Select Custom to customize system power settings Select Disabled to disable power saving settings The options are Disable Energy Efficient and Custom When this feature is set to Custom the f...

Страница 76: ...by the manufacturer The options are Disable and Enable Hardware PM Power Management State Control Available when Power Technology is set to Custom Hardware P States If this feature is set to Disable h...

Страница 77: ...ntion state No Limit and Auto CPU T State Control Available when Power Technology is set to Custom Software Controlled T States If this feature is set to Enable CPU throttling settings will be support...

Страница 78: ...and Remote WViLF SNC Sub NUMA Cluster Select Enable for Sub NUMA Non uniform memory access Cluster support Select Auto for 1 cluster or 2 cluster support depending on the satuts of IMC Integrated Memo...

Страница 79: ...2000 2133 2200 2400 2600 and 2666 Data Scrambling for NVDIMM Select Enable to enable data scrambling for onboard NVDIMM memory to enhance system performance and security The options are Auto Disable a...

Страница 80: ...able Upon system power loss an ADR Automatic Diagnostic Repository sequence will be triggered to allow ADR to flush the write protected data buffers in the memory controller and place the DRAM in self...

Страница 81: ...feature can be edited when the item below ADDDC Sparing is set to Disable UEFI ARM Mirror If this feature is set to Enable mirror mode configuration settings for UEFI based Address Range memory will...

Страница 82: ...g Select Enable for Adaptive Double Device Data Correction ADDDC support which will not only provide memory error checking and correction but will also prevent the system from issuing a performance pe...

Страница 83: ...e x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto MCP0 IIO PCIe Br4 This feature configures the PCI E Bifuraction setting for a PCI E port specified by the user The options are x16 and Auto MCP1 IIO PCIe Br5...

Страница 84: ...ions are Disable and Enable Intel VT for Directed I O VT d Intel VT for Directed I O VT d Select Enable to use Intel Virtualization Technology support for Direct I O VT d by reporting the I O device a...

Страница 85: ...performance The options are Enable and Disable Intel VMD Technology Intel VMD for Volume Management Device on CPU1 VMD Config for PStack1 Intel VMD for Volume Management Device Select Enable to use t...

Страница 86: ...d by the system Select Enable to use the Intel Volume Management Device Technology for this specific root port The options are Disable and Enable Hot Plug Capable Available when the device is detected...

Страница 87: ...ature to enable PCI E Completion Timeout support for electric tuning The options are Yes No and Per Port South Bridge The following South Bridge information will display USB Module Version USB Devices...

Страница 88: ...re supported by the Intel PCH chip and displays the following items SATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH chip The options are Enable and...

Страница 89: ...evice installed on the SATA port specified by the user to start a COMRESET initialization The options are Enable and Disable SATA Device Type Use this item to specify if the device installed on the SA...

Страница 90: ...0 sSATA Port 3 Hot Plug Select Enable to support Hot plugging for the device installed on an sSATA port selected by the user which will allow the user to replace the device installed in the slot witho...

Страница 91: ...G and 3G NVMe Firmware Source This feature determines which type of the NVMe firmware should be used in your system The options are Vendor Defined Firmware and AMI Native Support VGA Priority This fea...

Страница 92: ...bled Ipv4 HTTP Support Select Enabled to enable Ipv4 HTTP boot support If this feature is disabled it will not create the Ipv4 HTTP boot option The options are Enabled and Disabled Ipv6 PXE Support Se...

Страница 93: ...e Auto IO 3F8h IRQ 4 IO 2F8h IRQ 4 IO 3E8h IRQ 4 and IO 2E8h IRQ 4 Serial Port 2 Configuration Serial Port 2 Select Enabled to enable the onboard serial port specified by the user The options are Enab...

Страница 94: ...t used in Console Redirection Make sure that the same speed is used in the host computer as well as the client computer A lower transmission speed may be required for long and busy lines The options a...

Страница 95: ...y OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad This feature select...

Страница 96: ...7 Bits and 8 Bits Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even...

Страница 97: ...ole Redirection after BIOS POST Power On Self Test When this feature is set to Bootloader legacy Console Redirection is disabled before booting the OS When this feature is set to Always Enable legacy...

Страница 98: ...r long and busy lines The options are 9600 19200 57600 and 115200 bits per second Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer ov...

Страница 99: ...cy on other timestamp calculation devices such as an x86 RDTSC Instruction embedded in the CPU The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer The options are...

Страница 100: ...in the list of public keys During system boot the platform firmware uses this trusted public key to verify a digital signature in an attempt to manage and control the security of the platform firmwar...

Страница 101: ...e sure to disable EV DFX Device Function On Hide support for the system to work properly EV DFX is under IIO Configuration in the Chipset North Bridge submenu 2 For more information on TPM please refe...

Страница 102: ...led to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Erasing Settings Erase Event Log Available when the item SMBIOS Event Log is set to En...

Страница 103: ...ount Increment Available when the item SMBIOS Event Log is set to Enabled Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multipl...

Страница 104: ...llowing information will display BMC Firmware Revision This feature indicates the firmware revision of the BMC Base board Management Controller used in your system IPMI Status This feature indicates I...

Страница 105: ...etting is Failover IPMI Network Link Status This item displays the IPMI Network Link status The default setting is Dedicated LAN Configuration Address Source This feature displays the source of the cu...

Страница 106: ...C Address VLAN Select Enabled for IPMI VLAN support The options are Disabled and Enabled If the item above VLAN is set to Enabled the following item will be available VLAN ID Use this feature to set t...

Страница 107: ...th of the password should be from 3 characters to 20 characters long User Password Use this feature to set the user password which is required to enter the BIOS setup utility The length of the passwor...

Страница 108: ...ed to enable Compatibility Service Module CMS which will support Legacy BIOS through UEFI to enhance system performance The options are Enabled and Disabled Key Management Provision Factory Default Ke...

Страница 109: ...tures for the system These values also indicate the size the keys numbers and the key source of the Authorized Signatures The options are Set New and Append Secure Boot Variable Size Key Key Sources T...

Страница 110: ...to boot from an EFI OS when the Legacy OS fails The options are Enabled and Disabled Fixed Boot Order Priorities This feature prioritizes the order of a bootable device from which the system will boo...

Страница 111: ...ter the name and the file path for the boot option are set press Enter to create the new boot option in the boot priority list Add New Driver Option Use this feature to select a new driver to add to t...

Страница 112: ...te from the boot priority list Delete Drive Option Select the target boot driver to delete from the boot priority list Hard Disk Drive BBS Priorities Boot Option 1 5 Network Drive BBS Priorities Boot...

Страница 113: ...ect Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and r...

Страница 114: ...As User Defaults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To...

Страница 115: ...those which will not allow the system to continue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually co...

Страница 116: ...cro com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagn...

Страница 117: ...assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These...

Страница 118: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 119: ...n dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan he...

Страница 120: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 121: ...s del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l instal...

Страница 122: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 123: ...els aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Warn...

Страница 124: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 125: ...una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s u...

Страница 126: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 127: ...nbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All conn...

Страница 128: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 129: ...ertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques cir...

Страница 130: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 131: ...e elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordin...

Страница 132: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 133: ...tornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient tou...

Страница 134: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 135: ...e code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto util...

Страница 136: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 137: ...SATA3 NVMe internal drives with an optional kit that adds an additional two 2 internal SATA3 NVMe drives for a total of four 4 drives F619P3 FT two 3 5 SATA3 internal drives PCI Expansion Slots The X...

Страница 138: ...4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 CNS14336 1 CNS13438 GB4943 1 2011 GB9254 2008 Class A and GB17625 1 2012 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canad...

Страница 139: ...e The recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system...

Страница 140: ...EFI BIOS recovery using a USB attached device follow the instructions below 1 Using a different machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DV...

Страница 141: ...you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed with...

Страница 142: ...t to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built i...

Страница 143: ...rupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power suppl...

Страница 144: ...140 SuperServer F619P2 3 FT User s Manual Appendix E BSMI Safety Warnings Declaration of the Presence Condition of the Restricted Substances Marking...

Страница 145: ...minated diphenyl ethers PBDE Chassis Chassis Fan Cable Motherboard Power Supply Hard Disk PDB Add on Card 1 0 1 wt 0 01 wt 2 3 Declaration of the Presence Condition of the Restricted Substances Markin...

Страница 146: ...142 SuperServer F619P2 3 FT User s Manual 100 127 V 12 9 5 A 60 50 HZ 200 240 V 10 9 8 A 60 50 HZ 150 3 150 3...