12
FatTwin AS -F1114S-RNTR User's Manual
1
4
3
2
Figure 1-2. Node Control Panel
Node Control Panels
Each node has its own control panel, with the functions described below.
Control Panel Features
Item
Features
Description
1
Power Button
Applies or removes power from the power supply to the node with standby power
maintained
2
NIC LED
Indicates network activity on node when flashing
3
Information LED
Alerts operator to several states, as noted in the table below
4
UID Button
The Unit ID (UID) button is used to turn on or off the UID LED to more easily
locate the server in racks and server banks
Information LED
Status
Description
Continuously on and
red
An overheat condition has occurred.
(This may be caused by cable congestion.)
Blinking red (1Hz)
Fan failure, check for an inoperative fan.
Blinking red (0.25Hz)
Power failure, check for a non-operational power supply.
Solid blue
UID has been activated locally to locate the server in a rack
environment.
Blinking blue
UID has been activated using IPMI to locate the server in a
rack environment.