background image

SUPERSERVER

6028R-WTR

6028R-WTRT

®

   

S

UPER

USER’S MANUAL

Revision 1.0

Содержание 6028R-WTR

Страница 1: ...SUPERSERVER 6028R WTR 6028R WTRT SUPER USER S MANUAL Revision 1 0...

Страница 2: ...f any such disputes Supermicro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Страница 3: ...TRT uses 10Gps dual LAN ports Manual Organization Chapter 1 Introduction The first chapter provides a checklist of the main components included with the server system and describes the main features o...

Страница 4: ...he serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC815TS R740WBP server chassis You should follow the procedures given in this chapter when installing...

Страница 5: ...Notes Preface v...

Страница 6: ...ME 1 4 1 4 Contacting Supermicro 1 6 Chapter 2 Server Installation 2 1 Overview 2 1 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 2 2 4 Warnings and Precautions...

Страница 7: ...ions 4 4 Circuit Breaker 4 5 Power Disconnection Warning 4 6 Equipment Installation 4 8 Restricted Area 4 9 Battery Handling 4 10 Redundant Power Supplies 4 12 Backplane Voltage 4 13 Comply with Local...

Страница 8: ...n of Jumpers 5 23 5 10 Onboard LED Indicators 5 26 5 11 SATA Connections 5 27 5 12 Installing Software 5 28 SuperDoctor 5 5 29 5 13 Serverboard Battery 5 31 Chapter 6 Advanced Chassis Setup 6 1 Static...

Страница 9: ...7 1 How To Change the Configuration Data 7 2 Starting the Setup Utility 7 2 7 2 Main Setup 7 2 7 3 Advanced Setup Configurations 7 3 7 4 Event Logs 7 23 7 5 IPMI 7 25 7 6 Boot 7 27 7 7 Security 7 28...

Страница 10: ...SUPERSERVER 6028R WTR T USER S MANUAL x Notes...

Страница 11: ...ne 1 76 cm 16 pin to 16 pin 28AWG front control cable CBL 0071L SATA Accessories One 1 SATA backplane BPN SAS 825TQ O P Eight 8 drive carriers MCP 220 00075 0B Two 2 sets of four SATA 56 45 5 35 23 cm...

Страница 12: ...mory in 1 GB 2 GB 4 GB 8 GB 16 GB 32 GB and 64 GB size 1 2V voltage See Chapter 5 for details Note For the latest CPU memory updates please refer to our website at http www supermicro com products ser...

Страница 13: ...e The power supplies are both redundant hot plug Hard Drive Subsystem The SC815 chassis was designed to support eight 8 SATA 3 hot swap hard drives The SuperServer 6028R WTR T system can use 2 5 SATA...

Страница 14: ...ncy Although IPNM Specification Version 2 0 is supported by the BMC Baseboard Management Controller your system must also have IPNM compatible Manageability Engine ME 2 0 firmware installed to use thi...

Страница 15: ...PROCESSOR PROCESSOR QPI DDR4 DIMM 2 1 DDR4 DIMM DDR4 DIMM BMC SATAGen3 0 5 2 3 REAR AST2400 DDR4 DIMM B DDR4 DIMM C D SocketID 01 E H F 1 2 1 2 1 2 2 1 1 2 1 2 x16 Left SLOT SXB1B lower PCIE 3 0 x16 S...

Страница 16: ...m Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supe...

Страница 17: ...ged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the SuperServer 6028R W...

Страница 18: ...rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from t...

Страница 19: ...Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature Tmra Reduced Airflow Equipment should be moun...

Страница 20: ...Warning Slide rail mounted equipment is not to be used as a shelf or a work space Separating the Sections of the Rack Rails The chassis package includes two rail assemblies in the rack mounting kit Ea...

Страница 21: ...Extension Outer Rack Rails Outer rails attach to the rack and hold the chassis in place The outer rails for the SC825 chassis extend between 30 inches and 33 inches Installing the Outer Rails to the R...

Страница 22: ...er rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked position 4 Optional screws may be used t...

Страница 23: ...specific components There are also two buttons on the chassis control panel 3 2 Control Panel Buttons There are two buttons located on the front of the chassis a reset button and a power on off button...

Страница 24: ...hapter 6 for details on replacing the power supply This LED should be off when the system is operating normally NIC1 Indicates network activity on the LAN1 port when flashing Information LED See the f...

Страница 25: ...drive carrier has two LEDs SATA Drives Green When illuminated the green LED on the SATA drive carrier indicates drive activity A connection to the SATA backplane enables this LED to blink on and off...

Страница 26: ...SUPERSERVER 6027R 73DARF User s Manual 3 4 Notes...

Страница 27: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 28: ...considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar e...

Страница 29: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 30: ...ie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de branch...

Страница 31: ...erstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuito...

Страница 32: ...he power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 250V 20A Waarschuwing Dit product is afhankelijk van de kortsluitbevei...

Страница 33: ...tado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sourc...

Страница 34: ...rnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o u...

Страница 35: ...eug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich Advertencia Esta unidad ha sido dise ada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una d...

Страница 36: ...ame or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een...

Страница 37: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 38: ...ellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por comple...

Страница 39: ...System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero...

Страница 40: ...e Installation der Ger te muss den Sicherheitsstandards entsprechen Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtig...

Страница 41: ...onal laws and regulations Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L quipement doit tre install conform ment aux normes lectriqu...

Страница 42: ...age de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning The fans might still be...

Страница 43: ...tfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del v...

Страница 44: ...CSA Supermicro UL CSA UL CSA Warnung Bei der Installation des Produkts die zur Verf gung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu e...

Страница 45: ...s dispositivos el ctricos que los productos designados por Supermicro solamente Attention Lors de l installation du produit utilisez les bables de connection fournis ou d sign L utilisation d autres c...

Страница 46: ...bels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CS...

Страница 47: ...hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wris...

Страница 48: ...ations noted should be connected See the layout on page 5 10 for connector locations One 77 cm 10 pin to 10 pin 26 AWG two channel USB cable CBL 0263L Two 29 cm 30 AWG SATA cables CBL 0483L One 27 cm...

Страница 49: ...el JF1 contains header pins for various front control panel connectors See Figure 5 1 for the pin locations of the various front control panel buttons and LED indicators All JF1 wires have been bundle...

Страница 50: ...e locations of the various I O ports Figure 5 2 Rear I O Ports Rear I O Ports 1 VGA Port 2 USB 3 0 Port 0 3 USB 3 0 Port 1 4 IPMI Dedicated LAN Port 5 USB 3 0 Port 2 6 USB 3 0 Port 3 7 Gigabit LAN1 X1...

Страница 51: ...install the CPU heatsink If you buy a CPU separately make sure that you use an Intel certified multi directional heatsink only Make sure to install the serverboard into the chassis before you install...

Страница 52: ...ket Keys CPU Keys 4 Using your thumb and the index finger remove the WARNING plastic cap from the socket 5 Use your thumb and index finger to hold the CPU by its edges Align the CPU keys which are sem...

Страница 53: ...the CPU is aligned properly 7 With the CPU in the socket inspect the four corners of the CPU to make sure that they are flush with the socket 8 Close the load plate Lock the lever labeled Close 1st th...

Страница 54: ...th those on the Motherboard s and the Heatsink Bracket underneath Install the SNK P0048PSC heatsink in the CPU1 location cut out facing to the rear and install the SNK P0048PS heatsink in the CPU2 loc...

Страница 55: ...ws from the motherboard in the sequence as shown in the illustration below 2 Gently wriggle the heatsink to loosen it from the CPU Do not use excessive force when wriggling the heatsink 3 Once the CPU...

Страница 56: ...nstallation Installing Memory Modules 1 Insert the desired number of DIMMs into the memory slots starting with P1 DIMMA1 See the Memory Installation Tables below 2 Insert each DIMM module vertically i...

Страница 57: ...DIMMA1 P1 DIMMB1 1 CPU 4 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 1 CPU 5 8 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 Any memory pairs in P1 DIMMA2 P1 DIMMB2 P1 DIMMC2 P1 DIMMD2 slo...

Страница 58: ...MHz 1866 MHz RDIMM DRx4 16GB 32GB 2133 MHz 2133 MHz 1866 MHz LRDIMM QRx4 32GB 64GB 2133 MHz 2133 MHz 2133 MHz Note Please refer to our website http www supermicro com products serverboard for the late...

Страница 59: ...the shield for the PCI slot you wish to populate 2 Fully seat the card into the slot pushing down with your thumbs evenly on both sides of the card 3 Finish by using a screw to secure the top of the c...

Страница 60: ...ALWAYS POPULATE DIMMx1 FIRST P1 DIMMA1 P1 DIMMA2 P1 DIMMB1 P1 DIMMD2 P1 DIMMC1 P1 DIMMC2 P1 DIMMD1 P2 DIMMF2 P2 DIMMF1 P2 DIMME2 P2 DIMME1 SXB1C SXB1B CPU1 PCI E 3 0 X16 CPU2 PCI E 3 0 X16 UID SW LAN...

Страница 61: ...or the mezzanine HBA card Battery JBAT1 Onboard CMOS Battery See Chpt 3 for used battery disposal COM1 Backplane COM port Fan1 4 FanA B CPU System fan headers Fan1 Fan4 PCH Peripheral fan headers FanA...

Страница 62: ...ard slot Right See Note 3 below UID SW UID Switch BP USB 0 1 3 0 Backpanel USB 3 0 Port 0 Port 1 BP USB 2 3 3 0 Backpanel USB 3 0 connections 2 3 FP USB 4 5 3 0 Front Accessible USB 3 0 connections he...

Страница 63: ...supply and serverboard ATX Power 24 pin Connector Pin Definitions JPWR1 Pin Definition Pin Definition 13 3 3V 1 3 3V 14 12V 2 3 3V 15 COM 3 COM 16 PS_ON 4 5V 17 COM 5 COM 18 COM 6 5V 19 COM 7 COM 20...

Страница 64: ...7 and 8 of Front Control Panel to use the Overheat Fan Fail Power Fail and UID LED connections The Red LED on pin 8 provides warnings of overheating fan failure or power failure The Blue LED on pin 7...

Страница 65: ...et ports support 10G LAN connections on the X10DRW iT and Gigabit LAN connections on the X10DRW i In addition an IPMI_ Dedicated LAN that supports Gigabit LAN is located above USB 0 1 ports on the bac...

Страница 66: ...ND_DRAIN 8 D 9 D Front Panel USB 3 0 4 5 Pin Definitions Pin Definition Pin Definition 1 5V 2 5V 3 USB_PN2 4 USB_PN3 5 USB_PP2 6 USB_PP3 7 Ground 8 Ground 9 Key 10 Ground TPM Port 80 Header A Trusted...

Страница 67: ...more information on IPMI please refer to the IPMI User s Guide posted on our website http www supermicro com UID Switch Pin Definition 1 Ground 2 Ground 3 Button In 4 Ground UID LED Status Color State...

Страница 68: ...lock 2 Data 3 PMBUS_Alert 4 Ground 5 3 3V IPMB A System Management Bus header for IPMI 2 0 is located at JIPMB1 Connect the appropriate cable here to use the IPMB I2 C connection on your system IPMB H...

Страница 69: ...is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS 1 First power down th...

Страница 70: ...on the right for jumper settings BMC Enable Disable Jumper Settings JPB1 Jumper Setting Definition Pins 1 2 BMC Enable Pins 2 3 Normal Default LAN Enable Disable JPL1 enables or disables Gigabit_ LAN...

Страница 71: ...C to PCI Express slots to improve PCI performance These two jumpers are to be set at the same time The default setting is on pins 2 3 to disable the connection for normal operations See the table on t...

Страница 72: ...plane on the serverboard Each Ethernet LAN port has two LEDs The yellow LED indicates activity Link LED located on the left side of the LAN port may be green amber or off indicating the speed of the c...

Страница 73: ...I S1 State SATA 3 0 Ports There are ten SATA 3 0 I SATA 0 5 S SATA0 3 on the serverboard I SATA ports are supported by the Intel PCH C612 and S SATA ports are supported by the Intel SCU chip These SAT...

Страница 74: ...ectory and locate the ISO file for your serverboard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Anoth...

Страница 75: ...onitoring program that functions in a command line or web based interface in Windows and Linux operating systems The program monitors system health information such as CPU temperature system voltages...

Страница 76: ...5 Interface Display Screen Remote Control Note The SuperDoctor 5 program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products nfo sms_sd5 cfm For Linux...

Страница 77: ...y the manufacturer CR2032 Dispose of used batteries according to the manufacturer s instructions Figure 5 9 Installing the Onboard Battery Please handle used batteries carefully Do not damage the batt...

Страница 78: ...5 32 SUPERSERVER 6028R WTR T USER S MANUAL Notes...

Страница 79: ...very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded m...

Страница 80: ...e cooling for the system It is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool th...

Страница 81: ...o be shut down since the fans are hot pluggable Installing a New Fan 1 Replace the failed fan with an identical 8 cm 12 volt fan available from Supermicro 2 Position the new fan into the space vacated...

Страница 82: ...ite at http www supermicro com products nfo files storage SAS CompList pdf SAS SATA Drive Installation These drives are mounted in carriers to simplify their installation and removal from the chassis...

Страница 83: ...ts and make sure no ribbon cables touch the backplane or obstruct the holes which aid in proper airflow Hard Drive Backplane The hard drives plug into a backplane that provides power drive ID and bus...

Страница 84: ...s are typically needed to mount a slim DVD ROM drive in the server Accessing the Inside of the Chassis 1 Grasp the two handles on either side and pull the unit straight out until it locks you will hea...

Страница 85: ...eplace the failed unit without powering down the system Removing Replacing the Power Supply You do not need to shut down the system to replace a power supply module The backup power supply module will...

Страница 86: ...6 8 SUPERSERVER 6027R 73DARF User s Manual Notes...

Страница 87: ...options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved f...

Страница 88: ...the system In no event shall the manufacturer be liable for direct indirect special incidental or consequential damage arising from a BIOS update If you have to update the BIOS do not shut down or res...

Страница 89: ...oot Use this feature to select the bootup screen display between POST messages or the OEM logo Select Disabled to display the POST messages Select Enabled to display the OEM logo The default setting i...

Страница 90: ...m is enabled the BIOS will automatically reboot the system from a specified boot device again after its initial boot failed The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch...

Страница 91: ...cessor Cores Intel HT Hyper Threading Technology Intel VT x Virtualization Technology Intel SMX Trusted Execution Technology L1 Data Cache L1 Code Cache L2 Cache L3 Cache CPU Speed This item displays...

Страница 92: ...cute Disable Bit which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot thus preventing a worm or a virus from flooding illega...

Страница 93: ...he system for the change to take effect Please refer to Intel s website for detailed information CPU Power Management Configuration This submenu allows the user to configure the following CPU Power Ma...

Страница 94: ...CPU C7 State is a processor specific low C State The options are Enabled and Disabled Package C State limit Available when Power Technology is set to Custom This feature allows the user to set the lim...

Страница 95: ...idge This feature allows the user to configure the settings for the Intel North Bridge Integrated IO Configuration Intel VT d Select Enabled to enable Intel Virtualization Technology support for Direc...

Страница 96: ...IIO 2 PCIe Port Bifurcation Control This submenu configures the following IO PCIe Port Bifurcation Control settings for IIO 1 PCIe ports to determine how the available PCI Express lanes to be distrib...

Страница 97: ...DIMM Information The status of the memory modules detected by the BIOS will be displayed Memory Mode When Independent is selected all DIMMs are available to the operating system When Mirroring is sele...

Страница 98: ...every day The options are Enabled and Disabled Demand Scrub Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found on a memory module When the CPU or I O issues...

Страница 99: ...ontroller 2 to enhance system performance The options are Disabled and Enabled Legacy USB Support Available when USB Functions is not Disabled Select Enabled to support legacy USB devices Select Auto...

Страница 100: ...ble The default of SATA Controller 1 is Enhanced AHCI Mode The following items are displayed when the AHCI Mode is selected Aggressive Link Power Management When this feature is set to Enabled the SAT...

Страница 101: ...us Select 64 to set the PCI latency to 64 PCI clock cycles The options are 32 PCI Bus Clock 64 PCI Bus Clock 96 PCI Bus Clock 128 PCI Bus Clock 160 PCI Bus Clock 192 PCI Bus Clock 224 PCI Bus Clock an...

Страница 102: ...oard LAN Option ROM Select Select iSCSI to use the iSCSI Option ROM to boot the computer using a network device Select PXE Preboot Execution Environment to use an PXE Option ROM to boot the computer u...

Страница 103: ...5 6 7 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 10 11 12 Device Mode Use this feature to select the desired mode for a serial port specified The options are Normal and High Speed SOL Serial_Over_LAN Configur...

Страница 104: ...If this feature is set to enabled the following items will display Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client comput...

Страница 105: ...ommunication Select 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control This feature allows the user to set the flow control for Console Redirection to prevent data loss caused...

Страница 106: ...the user to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Out of Band Mgmt Management Port Use this feature to select the port...

Страница 107: ...ty bit to be sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the en...

Страница 108: ...ettings ME BIOS Interface Version ME Version Trusted Computing Available if a TPM device is installed Configuration TPM Support Select Enabled on this item and enable the TPM jumper on the serverboard...

Страница 109: ...plays status of TXT Feature support TXT Support Indicates if TXT support is enabled or disabled The default setting is Disabled Intel TXT Dependencies Displays a list of features that must be supporte...

Страница 110: ...t When Log is Full This option automatically clears the Event Log memory of all messages when it is full The options are Do Nothing and Erase Immediately Log System Boot Event This option toggles the...

Страница 111: ...or all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next reset to erase all system event logs upon next system reboot Select Yes On ever...

Страница 112: ...to Yes the user is allowed to configure the IPMI settings at next system boot Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Sta...

Страница 113: ...oot Device Use this feature to specify the sequence of boot priority for a device specified by the user Add New Boot Option This feature allows the user to configure the following settings when adding...

Страница 114: ...1st Device Network Device BBS Priorities This submenu allows the user to specify the boot priority sequence of a network device 1st Device UEFI Boot Device BBS Priorities This submenu allows the user...

Страница 115: ...Administrator Password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long 7 8 Save Exit This submenu allows the user to con...

Страница 116: ...ing you if you want to load previous values select Yes to load the values previous saved or select No to keep the changes you ve made so far Restore Optimized Defaults Select this feature and press En...

Страница 117: ...S 7 31 Boot Override This feature allows the user to override the Boot Option Priorities setting in the Boot menu and instead immediately boot the system with one of the listed devices This is a one t...

Страница 118: ...7 32 SUPERSERVER 6028R WTR T USER S MANUAL Notes...

Страница 119: ...e repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error Beep Code Erro...

Страница 120: ...A 2 SUPERSERVER 6028R WTR T USER S MANUAL Notes...

Страница 121: ...8 MB SPI AMI BIOS SM Flash UEFI BIOS Memory Capacity Sixteen 16 DIMM slots that can support up to 1024 GB of ECC RDIMM or LRDIMM DDR4 2133 1866 1600 1333 MHz speed memory in 1 GB 2 GB 4 GB 8 GB 16 GB...

Страница 122: ...to 158 F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Note The system power supplies are redundant hot plug Regulatory Compliance Electrom...

Страница 123: ...B 3 Appendix B System Specifications Notes...

Страница 124: ...erform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such...

Отзывы: