System 5130AD-T User's Manual
92
Offset Prefi x
Use this feature to set the Offset value as a positive (+) number or a negative (-) number.
The default setting is
"+"
.
GT-UnSliced VR Settings
GT-UnSliced Domain
VR Confi g Enable
Select Enable to activate VR confi guration options. The options are
Enabled
and Disabled.
AC Loadline
AC Loadline is defi ned in 1/100 mOhms and uses the BIOS mailbox command 0x2. A value
of 100 equals 1.0 mOhm, and 1255 is 12.55 mOhms. Range is 0-6249 (0-62.49 mOhms).
Enter
0 for AUTO
.
DC Loadline
DC Loadline is defi ned in 1/100 mOhms and uses the BIOS mailbox command 0x2. A value
of 100 equals 1.0 mOhm, and 1255 is 12.55 mOhms. Range is 0-6249 (0-62.49 mOhms).
Enter
0 for AUTO.
PS Current Threshold1
The PS Current Threshold1 is defi ned in 1/4A (Amperes) increments and uses the BIOS
mailbox command 0x3. A value of 400 equals 100A. Range is 0-512 which translates to
0-128A. Enter 0 for AUTO. Default is
80 for 20A.
PS Current Threshold2
The PS Current Threshold2 is defi ned in 1/4A (Amperes) increments and uses the BIOS
mailbox command 0x3. A value of 400 equals 100A. Range is 0-512 which translates to
0-128A. Enter 0 for AUTO. Default is
20
for 5A.
PS Current Threshold3
The PS Current Threshold2 is defi ned in 1/4A (Amperes) increments and uses the BIOS
mailbox command 0x3. A value of 400 equals 100A. Range is 0-512 which translates to
0-128A. Enter 0 for AUTO. Default is
20
for 5A.
PS3 Enable
Enable or Disables PS3. Uses BIOS VR mailbox command line 0x3. The options are
Enabled
and Disabled.
PS4 Enable
Enable or Disables PS4. Uses BIOS VR mailbox command line 0x3. The options are
Enabled
and Disabled.