background image

USER'S MANUAL

Revision 1.0

High Performance 

Desktop System

5130AD-T

Содержание 5130AD-T

Страница 1: ...USER S MANUAL Revision 1 0 High Performance Desktop System 5130AD T...

Страница 2: ...operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may ca...

Страница 3: ...drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety info htt...

Страница 4: ...ns Precautions 15 2 4 Accessing the Inside of the System 16 Left Side and Right Side Covers 16 Front Bezel 17 Chapter 3 Maintenance and Component Installation 3 1 Removing Power 18 3 3 Motherboard Com...

Страница 5: ...45 4 4 Jumpers 48 Explanation of Jumpers 48 4 5 LED Indicators 51 Chapter 5 Software 5 1 OS Installation 52 Installing the Windows OS for a RAID System 52 Installing Windows to a Non RAID System 52 5...

Страница 6: ...Statements for AC Systems B 1 About Standardized Warning Statements 117 Appendix C System Specifications Appendix D UEFI BIOS Recovery D 1 Overview 138 D 2 Recovering the UEFI BIOS Image 138 D 3 Recov...

Страница 7: ...r B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supe...

Страница 8: ...ny equipment appears damaged please file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the server It should be situated in a clean dus...

Страница 9: ...Thunderbolt AIC support Two 2 M 2 slots Hard Drive Bays Supports up to ten 3 5 and 2 5 HDD or SSD drives with tool less trays The GS5A 753R chassis standard configuration includes two 5 25 drive bays...

Страница 10: ...es a front panel allowing easy access to the system power and communication ports The in addition to the HDD Activity LED the Power button and the Reset button the following ports are available on the...

Страница 11: ...Front grille with one click access to dust filter 4 Rear I O ports Rear I O ports for system shown as an example your system I O ports may look different 5 Expansion Cards Slots Openings for expansion...

Страница 12: ...LAN1 ON PWR RST X OH FF NIC NIC 1 LED HDD LED PWR OFF DISABLE ON ENABLE JI2C1 JI2C2 AUDIO FP 3 PIN POWER LED JLED1 ON BIOS RECOVERY COM1 JTPM1 TPM PORT80 OFF NORMAL JBR1 JL1 CHASSIS INTRUSION USB6 7...

Страница 13: ...ts HDMI DP High Definition Multimedia Interface Display Port I SATA0 5 Intel Z270 Serial ATA SATA 3 0 Ports 0 5 6Gb sec JD1 Speaker buzzer Pins 1 4 External Speaker Pins 3 4 Buzzer JF1 Front Control P...

Страница 14: ...0_x4 ASMedia Switch ASM1480 U 2 SOCKET SSD M 2 SOCKET SSD ASMedia Switch ASM1480 8GT s PCIe3 0_x2 2 X SATA III SATA III 6Gb s M 2 SOCKET SSD PCIe3 0_x2 8GT s SATA III U 2 SOCKET SSD 8GT s PCIe3 0_x4...

Страница 15: ...enerated You will also need it plugged into a grounded power outlet Be sure to read the Warnings and Precautions in the next section 2 3 Warnings and Precautions Review the electrical and general safe...

Страница 16: ...wing easy access to the system interior Caution Except for short periods of time do not operate the system without the cover in place The chassis cover must be in place to allow proper airflow Left Si...

Страница 17: ...er 2 Server Installation 17 Front Bezel Remove the front bezel by pulling it off from the bottom of the bezel This should only be necessary when replacing the front fans Figure 2 2 Removing the Front...

Страница 18: ...completely shut down disconnect the AC power cord s from the power strip or outlet If your system has more than one power supply remove the AC power cords from all power supply modules 3 Disconnect th...

Страница 19: ...a Processor 1 Press the load lever to release the load plate which covers the CPU socket from its locking position 2 Gently lift the load lever to open the load plate Remove the plastic cap Load Lever...

Страница 20: ...U or the socket 5 With the CPU inside the socket inspect the four corners of the CPU to make sure that the CPU is properly installed 6 Use your thumb to gently push the load lever down to the lever lo...

Страница 21: ...sest to the CPU fan power connector and are not interfered with other components 3 Inspect the CPU Fan wires to make sure that the wires are routed through the bottom of the heatsink 4 Remove the thin...

Страница 22: ...steners are securely inserted into the mounting holes and the heatsink is properly installed on the motherboard connect the heatsink fan wires to the CPU Fan connector Note It is recommended that you...

Страница 23: ...ner cap and turn it counterclockwise to make a 1 4 900 turn and pull the fastener upward to loosen it Removing the Heatsink We do not recommend that the CPU or the heatsink be removed However if you d...

Страница 24: ...2 2 3 DISABLE 1 2 ENABLE JPL2 LAN2 LAN2 LAN1 ON PWR RST X OH FF NIC NIC 1 LED HDD LED PWR OFF DISABLE ON ENABLE JI2C1 JI2C2 AUDIO FP 3 PIN POWER LED JLED1 ON BIOS RECOVERY COM1 JTPM1 TPM PORT80 OFF NO...

Страница 25: ...s into place 6 Press the release tabs to the lock positions to secure the DIMM module into the slot Removing Memory Modules Reverse the steps above to remove the DIMM modules from the motherboard Caut...

Страница 26: ...implemented a design change in the Windows XP with Service Pack 2 SP2 and Windows Vista This change is specific to the behavior of Physical Address Extension PAE mode which improves driver compatibil...

Страница 27: ...e left side chassis cover 2 Remove the blank PCI shield from the rear of the chassis by removing the thumb screw 3 Insert the expansion card into the motherboard expansion slot while aligning the expa...

Страница 28: ...lide one edge under the lip of the holder with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in...

Страница 29: ...eatures Black anodized brushed aluminum fascia front panel with two USB 3 0 ports Removable 3 5 and 2 5 HDD SSD cages with tool less trays for up to 10 drives Tool less 5 25 device installation with t...

Страница 30: ...age device such as a 3 5 HDD 2 5 HDD or solid state drive The four 2 5 bays are housed in a removable cage Two additional removable cages can each accommodate three 2 5 or 3 5 drives The SAS SATA driv...

Страница 31: ...the carrier 2 Swing the handle fully out 3 Grasp the handle and use it to pull the drive carrier out of its bay Installing a Storage Device in the 5 25 Drive Tray You can install a 3 5 drive one or tw...

Страница 32: ...u can also install three drives into each of the upper and lower combination cages Figure 3 5 Installing Drives and Mounting Brackets in to the Cage 1 Open the chassis left side cover 2 Remove the dri...

Страница 33: ...33 Chapter 3 Maintenance and Component Installation Figure 3 6 Mounting Tray for 3 5 Drive Figure 3 7 Mounting Tray for 2 5 Drive...

Страница 34: ...ther fan mounts and configurations are possible Two front fans can be upgraded to 140mm Three fans can be mounted on the chassis top 120mm or 140mm One fan can be mounted on the chassis bottom 120mm F...

Страница 35: ...ent Installation Adding or Changing Fans To upgrade the standard front fans remove the chassis front cover To add a fan to the chassis bottom the lower 3 5 HDD cage must be removed See Figure 3 9 Figu...

Страница 36: ...Radiator Water Cooled Heat Sink The chassis supports a water cooled CPU heat sink A 120 mm radiator can be placed over the rear fan A 240 mm radiator can be place just under the top of the chassis Co...

Страница 37: ...Front Dust Filter 1 Disengage the filter by pushing on the top edge center The top pops loose 2 Rotate the filter top downward to release it from the hinge points on the bottom 3 Clean the filter 4 Re...

Страница 38: ...130AD T User s Manual 38 Power Supply The 5130AD T system comes with a 750 Watt power supply Mount it on the rear floor of the chassis The power supply fan may be on top recommended or under the power...

Страница 39: ...y 24 pin Primary ATX Power JPWR1 8 pin Processor Power JPWR2 Main ATX Power Connector The 24 pin main power connector JPW1 is used to provide power to the motherboard The 8 pin CPU PWR connector JPW2...

Страница 40: ...red Connection Processor Power Connector JPW2 must also be connected to the power supply This connector is used to power the processor s Fan Header Pin Definitions Pin Definition 1 Ground Black 2 12V...

Страница 41: ...definitions Onboard PWR LED Pin Definitions Pin Definition 1 VCC 2 No Connection 3 Connection to PWR LED in JF1 DOM PWR Connector JSD1 The Disk On Module DOM power connector located at JSD1 provides 5...

Страница 42: ...d See the table at right for pin definitions for the header 10 in Audio Pin Definitions Pin Signal 1 Microphone_Left 2 Audio_Ground 3 Microphone_Right 4 Audio_Detect 5 Line_2_Right 6 Ground 7 Jack_Det...

Страница 43: ...Ground 2 1 20 19 Power Button Pin Definitions JF1 Pin Definition 1 Signal 2 Ground Power Button The Power Button connection is located on pins 1 and 2 of JF1 Momentarily contacting both pins will powe...

Страница 44: ...ED 8 OH Fan Fail LED LAN1 LAN2 LED Pin Definitions JF1 Pin Definition 9 NIC2 Activity LED 10 NIC2 Link LED 11 NIC1 Activity LED 12 NIC1 Link LED NIC1 NIC2 LAN1 LAN2 The NIC Network Interface Controlle...

Страница 45: ...wer Cables The following power connections on the C7Z270 PG must be connected to the power supply The wiring is included with the power supply See Section 4 1 for details 24 pin Primary ATX Power JPW1...

Страница 46: ...Bus USB Two Universal Serial Bus 2 0 ports 0 1 two USB 3 0 ports 8 9 four USB 3 1 ports 10 11 12 13 are located on the I O back panel In addition one USB 3 0 header two ports 14 15 three USB 2 0 heade...

Страница 47: ...as VGA DVI or HDMI Serial Port COM1 There is one serial COM port header on the motherboard COM1 is located next to the 1394 connection header See the table on the right for pin definitions SATA Conne...

Страница 48: ...nnector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing...

Страница 49: ...Short Enabled Open Default Disabled Audio Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled Audio Enable JPAC1 JPAC1 allows you to enable or disable the onbo...

Страница 50: ...on the right for jumper settings BIOS Recovery JBR1 The BIOS Recovery jumper JBR1 is used to enable or disable the BIOS Recovery feature of the motherboard See Appendix D for details Power Button POW...

Страница 51: ...d Power LED is located at LED1 on the motherboard When LED1 is on the AC power cable is connected Make sure to disconnect the power cable before removing or installing any component See the layout bel...

Страница 52: ...rt on the system Note for older legacy OS s please use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper driver...

Страница 53: ...er option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities to your hard dr...

Страница 54: ...ment Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you...

Страница 55: ...s chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens Note For AMI BIOS Recovery please refer to the UEFI BIOS Recovery Instructions in Appendix C Starting BIOS GUI Setu...

Страница 56: ...s The Main BIOS Setup screen has two main areas The left area is the Main Navigation and the main area is for the Information Section Icons that do not respond when the mouse pointer is hovering on to...

Страница 57: ...y can be accessed by pressing Del at the appropriate time during system boot Note For the purposes of this manual options that are printed in Bold are default settings How to Start the Setup Utility N...

Страница 58: ...ersion number Build Date and Time displays the BIOS build date and Time CPU displays the CPU type speed stepping etc CPU Fan Data displays sensor type temperature speed System Date Click on the date t...

Страница 59: ...speed ID displays the unique CPU ID Stepping displays the processor stepping Number of Processors displays the number of cores detected Microcode Revision displays the CPU s microcode patch version GT...

Страница 60: ...ted clock speed ID displays the unique CPU ID Speed this item shows the detected CPU speed L1 Data Cache indicates if Level 1 cache is supported L1 Instruction Cache displays if Level 1 instruction ca...

Страница 61: ...etch Available when supported by the CPU Select Enabled for the CPU to prefetch both cache lines for 128 bytes as comprised Select Disabled for the CPU to prefetch both cache lines for 64 bytes The op...

Страница 62: ...ted Technology Intel TXT Trusted Execution Technology helps protect against software based attacks and ensures protection confidentiality and integrity of data stored or created on the system The opti...

Страница 63: ...ust processor voltage and core frequency in an effort to reduce power consumption and heat dissipation Please refer to Intel s web site for detailed information The options are Disabled and Enabled C...

Страница 64: ...led C1 C3 and C1 and C3 Package C State Demotion This item enables the Package C State demotion The options are Disabled and Enabled Package C State Un Demotion When set the CPU will conditionally un...

Страница 65: ...are Enabled and Disabled Maximum GT Frequency This option is the Maximum GT Frequency as defined by the user Choose between 300MHz RPN and 1200MHz RP0 Any value beyond this range will be clipped to i...

Страница 66: ...Cores Use this feature to select the number of active processor cores The options are All 1 2 3 and 4 these options depend on how many cores are supported by the CPU Load SMC CPU OC Setting This item...

Страница 67: ...SR Lock This feature enables or disables the locking of Package Power Limit settings When enabled Package Power Limit MSR will be locked and a reset will be required to unlock the register The options...

Страница 68: ...r a period of time see item below A lower limit can save power and protect the CPU while a higher limit improves performance This value must be between Min Power Limit TDP limit If value is 0 the BIOS...

Страница 69: ...lect the Core Turbo voltage mode Select a value Core Voltage Offset Use this feature to set the CPU Voltage Offset value from 500mV to 500mV Enter 0 to use the manufacturer default value Offset Prefix...

Страница 70: ...YS Slope is defined in 1 100 increments and uses the BIOS VR mailbox command 0x9 Range is 0 200 For example enter 125 for a 1 25 slope Enter 0 for AUTO PSYS Offset PSYS Offset is defined in 1 4 increm...

Страница 71: ...Disable Fast PKG C State Ramp for SA Domain Select False to leave Fast ramp enabled during deeper C States Selecting True will disable Fast ramp during deeper C States The options are True and False...

Страница 72: ...Disables PS3 Uses BIOS VR mailbox command line 0x3 The options are Enabled and Disabled PS4 Enable Enable or Disables PS4 Uses BIOS VR mailbox command line 0x3 The options are Enabled and Disabled IMO...

Страница 73: ...ons are Enabled and Disabled TDC Current Limit The TDC Current Limit is defined in 1 8A Amperes increments and uses the BIOS mailbox command 0x1A A value of 1000 equals 125A Range is 0 32767 Enter 0 f...

Страница 74: ...n selects the type speed of the memory installed The options are 1333 1600 1867 2133 2400 2667 2933 and 3200 All values are in MHz Default speed is auto detected Memory Scrambler This feature enables...

Страница 75: ...Memory Remap PCI memory resources will overlap with the total physical memory if 4GB of memory or above is installed on the motherboard When this occurs Enable this function to reallocate the overlapp...

Страница 76: ...type speed of the memory installed The options are Auto DDR4 1067MHz DDR4 1333MHz DDR4 1600MHz DDR4 1867MHz DDR4 2133MHz DDR4 2400MHz DDR4 2667MHz DDR4 2933 and DDR4 3200MHz Default speed is auto dete...

Страница 77: ...ion configures the Internal Read to Precharge Command Delay Time Enter a number between 1 38 The default is 8 tWR This option configures the Minimum Write Recovery Time Enter a number between 1 38 The...

Страница 78: ...option configures the Write Early ODT Enter a numeric value The default is 0 tAONPD This option configures the tAONPD The default is 10 ODT_Always_Rank0 This option configures the ODT Always Rank0 En...

Страница 79: ...y tWRRD_dg Enter a numeric value The default is 23 tWRRD_dr This option configures the between module read to write delay tWRRD_dr Enter a numeric value The default is 6 tWRRD_dd This option configure...

Страница 80: ...ption configures tRDPDEN Enter a numeric value The default is 20 tWRPDEN This option configures tWRPDEN Enter a numeric value The default is 34 DIIBwEn 0 This option configures DIIBwEn 0 Enter a numer...

Страница 81: ...POST messages Bootup Num Lock Use this feature to set the Power on state for the Numlock key The options are Off and On Wait for F1 If Error Use this feature to force the system to wait until the F1 k...

Страница 82: ...the system as soon as the user presses the power button The options are Instant Off and 4 Seconds Override AC Loss Policy Depend On Use this feature to set the power state after a power outage Select...

Страница 83: ...to enable Serial Port 1 The default is Enabled Device Settings This item displays the current IRQ setting for Serial Port 1 COM1 Change Settings This item configures the IRQ setting for Serial Port 1...

Страница 84: ...he item above set to Enabled the following items will become available for configuration Console Redirection Settings Terminal Type This feature allows the user to select the target terminal emulation...

Страница 85: ...are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if slower devices are used T...

Страница 86: ...egacy Serial Redirection Port Select a COM port for Legacy Serial Redirection The options are dependent on the available COM ports Serial Port for Out of Band Management Windows Emergency Management S...

Страница 87: ...Flow Control Use this item to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop data sending when the receiving buffer is full Send...

Страница 88: ...ink Speed Select Auto Gen1 Gen2 or Gen3 to set the PEG Max Link Speed PEG Port Feature Configuration Detect Non Compliant Device Select Enable to activate detection of non compliant PCI Express device...

Страница 89: ...al Gfx Card on PEG and PCH PCIE Ports If this feature is enabled the system will not scan for a new card The options are Disabled or Enabled Primary Display Use this feature to select the graphics dev...

Страница 90: ...ch is the size of system memory reserved by the BIOS for graphics device use The options are 128MB 256MB 512MB 1024MB and 2048MB DVMT Pre Allocated Dynamic Video Memory Technology DVMT allows dynamic...

Страница 91: ...0mV to 2000mV Enter 0 to use the manufacture default value Offset Prefix Use this feature to set the Offset value as a positive number or a negative number The default setting is GT Unslice Domain GT...

Страница 92: ...shold1 The PS Current Threshold1 is defined in 1 4A Amperes increments and uses the BIOS mailbox command 0x3 A value of 400 equals 100A Range is 0 512 which translates to 0 128A Enter 0 for AUTO Defau...

Страница 93: ...crements A value of 400 equals 100A Set this number to 0 for Auto This uses the BIOS VR mailbox command 0x6 VR Voltage Limit This feature sets the Voltage Regulator voltage limit The value is represen...

Страница 94: ...0 128A Enter 0 for AUTO Default is 80 for 20A PS Current Threshold2 The PS Current Threshold2 is defined in 1 4A Amperes increments and uses the BIOS mailbox command 0x3 A value of 400 equals 100A Ran...

Страница 95: ...ox command 0x6 VR Voltage Limit This feature sets the Voltage Regulator voltage limit The value is represented in mV A value of 1250 equals 1 25V Set this number to 0 for Auto This uses the BIOS VR ma...

Страница 96: ...ve State Power Management ASPM to power manage the PCIe link during the various L states The options are Auto L0sL1 L1 L0s and Disabled PCIe Root Ports L1 Substates Use this feature to define which L1...

Страница 97: ...ith no BIOS override Range is from 0 0 to 2 0 SATA and RST Configuration SATA Controllers Select Disabled to disable the onboard SATA Controllers The settings are Enabled and Disabled SATA Mode Select...

Страница 98: ...r hot plugging Set this item to Enabled for hot plugging support which will allow the user to replace a SATA disk drive without shutting down the system The options are Enabled and Disabled Configured...

Страница 99: ...lowing information for the PCH Firmware ME Firmware Version ME Firmware Mode ME Firmware SKU ME FW Image Re Flash This item will update the PCH Firmware from an image in a USB Flashdrive attached to a...

Страница 100: ...uto to disable legacy support when legacy USB devices are not present If Disable is selected legacy USB devices will not be supported The options are Enabled Disabled and Auto XHCI Hand Off This item...

Страница 101: ...Use a SATA optical drive as a USB drive and USB CD DVD drives are not supported Disable this feature after the XHCI driver has been installed in Windows The options are Disabled and Enabled External U...

Страница 102: ...nboard LAN1 Option ROM Select PXE Preboot Execution Environment to boot the computer using a PXE device installed in a LAN port specified Select Disabled to prevent system boot using a device installe...

Страница 103: ...r the system If the Administrator password is defined ONLY this controls access to the BIOS setup ONLY If the User s password is defined ONLY this password will need to be entered upon each system boo...

Страница 104: ...dor Keys Attempt Secure Boot Select Enabled for Secure Boot flow control This feature is available when the platform key PK is pre registered the platform operates in the user mode and CSM is disabled...

Страница 105: ...system is in setup mode The options are Disabled and Enabled if Secure Boot Mode is set to Custom Key Management allows experienced users to modify Secure Boot Variables Install Factory Default Keys T...

Страница 106: ...or load from a file When prompted select Yes to load Factory Defaults or No to load from a file Append Key Exchange Key This item uploads and adds a Key Exchange Key into the Key Management You may in...

Страница 107: ...me Based Authenticated Variable When prompted select Yes to load Factory Defaults or No to load from a file Append Forbidden Signature This item uploads and adds an Forbidden Signature into the Key Ma...

Страница 108: ...ds and installs an OSRecovery Signature You may insert a factory default key or load from a file The file formats accepted are 1 Public Key Certificate a EFI Signature List b EFI CERT X509 DER Encoded...

Страница 109: ...ill be displayed CPU Temperature displays the CPU temperature detected by PECI System Temperature indicates the system internal temperature Peripheral Temperature displays the detected peripheral devi...

Страница 110: ...peed to allow the onboard fans to run at full speed of 100 Pulse Width Modulation Duty Cycle for maximum cooling This setting is recommended for special system configuration or debugging Select Stable...

Страница 111: ...from top to bottom to select devices Legacy Boot Option 1 8 The options are Hard Disk CD DVD USB Hard Disk USB CD DVD USB Key USB Floppy USB LAN Network and Disabled USB Key Drive BBS Priorities Use t...

Страница 112: ...Exit This option will discard the changes that have been made and will exit BIOS Setup Save Changes and Reset This option will save the changes that have been made and will reboot the system Discard C...

Страница 113: ...ash utility 2 At the prompt select Yes to reboot and configure the system to Flash mode Select No to cancel and view the BIOS information 3 After the system reboots to the flash mode the system is rea...

Страница 114: ...e will appear to show the progress of the BIOS flash 7 If the flash is successful a pop up message will indicate the result Select OK to complete the BIOS flash and to reboot the system Go to the SYST...

Страница 115: ...If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal er...

Страница 116: ...o com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnos...

Страница 117: ...or assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis Thes...

Страница 118: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 119: ...n dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan he...

Страница 120: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 121: ...s del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l instal...

Страница 122: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 123: ...els aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Warn...

Страница 124: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 125: ...una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s u...

Страница 126: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 127: ...anbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All con...

Страница 128: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 129: ...ertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques cir...

Страница 130: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 131: ...e elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordin...

Страница 132: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 133: ...tornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient tou...

Страница 134: ...tadores de CA La utilizaci n de otros cables y adaptadores podr a ocasionar un mal funcionamiento o un incendio Aparatos El ctricos y la Ley de Seguridad del Material proh be el uso de UL o CSA cables...

Страница 135: ...appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bij het...

Страница 136: ...2 5 drive bays and six combination bays that can house either 3 5 or 2 5 drives PCI Expansion Slots Four 4 PCI E 3 0 X16 slots One 1 PCI E 3 0 X4 for Thunderbolt AIC support Two 2 M 2 slots Motherboa...

Страница 137: ...N 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Perchlorate Warning California Best Management Practices Re...

Страница 138: ...of a recovery BIOS block and a main BIOS block a main BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user to flash a new BIOS image if th...

Страница 139: ...e it SUPER ROM for BIOS recovery use 2 Insert the USB device that contains the new BIOS image SUPER ROM into any available USB port Be sure the file is saved in the very top root folder 3 Set the JBR1...

Страница 140: ...mplete click OK to reboot the system Note At this point you may decide if you want to start with BIOS Recovery If you decide to proceed with BIOS Recovery follow the procedures below 5 To continue wit...

Страница 141: ...Megatrends Inc All Rights Reserved Reading flash done ME Data Size checking ok FFS checksums ok Erasing Boot Block done __Updating Boot Block 0x00A91000 13 BIOS Boot Block Corruption Occurrence When a...

Отзывы: