background image

www.Superiorfireplaces.US.com

126610-01A

2

Safety .............................................................................................2

Product Dimensions ......................................................................4

Fireplace Installation ......................................................................5

Venting Installation ........................................................................7

Optional Gas Line Installation ......................................................13

Operation and Maintenance Guidelines ........................................14

Replacement Parts .......................................................................15

Technical Service .........................................................................15

Parts ............................................................................................16

Accessories ..................................................................................16

Thank you for your purchase. We appreciate your 

business!

Please carefully read and follow all instructions in this manual. 

Pay 

special attention to all warnings and safety information.

Following these safety, care, and operation instructions will help 

ensure many years of dependable and enjoyable service from your 

fireplace.

Register your product online today!

To help us keep you up-to-date on product information and of-

fers, please take a few moments to register your product online 

at www.Superiorfireplaces.US.com 

(Owner Resources/Product 

Registration).

Please read and understand these instructions before installing 

or operating.

SAFETY

 WARNING: Improper installation, adjustment, 

alteration, service or maintenance can cause injury, 

property damage or loss of life. Refer to this manual 

for assistance or additional information. Consult a 

qualified installer or local distributor.

IMPORTANT: Check local codes before installing this 

fireplace.

This fireplace model is a wood burning fireplace intended and ap-

proved for installation in either residential homes or buildings of 

standard construction. This fireplace system requires the utilization 

of INNOVATIVE HEARTH PRODUCTS, LLC’s (IHP) 8", double-wall, 

and snap lock flue pipe system. 
Glass doors are optional with this fireplace and come in different 

styles. For more information see Glass Doors, page 14). Optional 

glass doors in several finishes are available for this fireplace (see 

Replacement Parts, page 15 and Accessories on page 16).
Before beginning installation of this fireplace, read these instructions 

through completely.

•  This  IHP  fireplace  and  its  components  are  safe  when  installed 

according to this installation manual. Unless you use IHP com-

ponents, which have been designed and tested for the fireplace 

system, you may cause a fire hazard.

•  The IHP warranty will be voided by and IHP disclaims any respon

-

sibility for the following actions.

a. Modification of the fireplace or any of the components manu-

factured by IHP unless otherwise permitted by IHP.
b. Use of any component part not manufactured or approved by 

IHP in combination with an IHP fireplace system.
c. Installation and/or operation in a manner other than instructed 

in this manual.
d. The burning of any other fuel not tested or approved by IHP  

in this wood burning fireplace.

Proper installation is the most important step in ensuring safe and 

continuous operation of the fireplace. Consult the local building codes 

as to the particular requirements concerned with the installation of 

TABLE OF CONTENTS

all factory built fireplaces.
Proper installation is the most important step in ensuring safe and 

continuous operation of the fireplace. Although grounding may not 

be required by code in your area, it must be electrically grounded in 

accordance with local codes or, in the absence of local codes, with 

the National Electrical Code, ANSI/NFPA 70-1990.
This firebox is intended for installation in accordance with the National 

Fire Protection Association Standard for Chimneys, Fireplaces, Vents 

and Solid-Fuel Burning Fireplaces, NFPA 211, and in accordance 

with codes such as the BOCA Basic/National Code, the Standard 

Mechanical Code, and the Uniform Building Code..

 WARNING: Do not install a fireplace insert in this 

fireplace unless the manufacturer's instructions with 

the insert specifically state this fireplace has been 

tested for use with this insert.

FOR YOUR SAFETY

• Do not store or use gasoline or any other flammable 

vapors or liquids in the vicinity of this or any other 

appliance.

• Due to high temperatures, the appliance should be 

located out of traffic and away from furniture and 

draperies.

• Do not place clothing or other flammable materials 

on or near the appliance.

• Never  leave  children  unattended  when  a  fire  is 

burning in the fireplace.

 WARNING: Use solid wood or processed solid 

fuel fire logs only. "Do not poke or stir the logs while 

they are burning. Use only firelogs that have been 

evaluated for the application in fireplace and refer to 

firelog warnings and caution markings on packaging 

prior to use."

Содержание WRT35STWSI Custom Series

Страница 1: ...e is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard...

Страница 2: ...ire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless other...

Страница 3: ...urn veryquickly DONOTusetreatedwood charcoal coal trash driftwoodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normall...

Страница 4: ...re itshallberemoved to reduce the risk of a chimney fire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or fully closed when operating fireplace WARNING Children an...

Страница 5: ...box Clearances Figure 2 Common Location of Fireplace Existing Wall Projected Wall 12 30 4 cm to Perpendicular Wall MINIMUM CLEARANCE TO COMBUSTIBLES Back and sides of fireplace 1 minimum Adjacent wall...

Страница 6: ...cm Min Clearance From Outer Pipes to Combustibles 1 2 5 cm Min To Combustibles 21 5 16 54 cm 42 5 8 108 cm 24 61 cm 12 31 cm Figure 7 Framing Firebox with Z Type Ember Protectors As Required by Desig...

Страница 7: ...ies on page 16 Avoid installing outside air eyebrow in areas where inlet opening may be blocked by snow bushes or other obstacles It should also be located beyond the reach of children CAUTION Combust...

Страница 8: ...18 36 and 48 The actual lineal gain for each is measured after each section is fully connected Lineal gain is the actual measurable length of a part after two or more parts are connected PIPE INSTALL...

Страница 9: ...wall pipe see offset chart and Figure 18 Maximum length of pipe between supports is 6 feet of angled run A Figure 18 Raise and Offset B A Screws Figure 16 Elbow Offset 30 FT 9 14m 30 FT 9 14m Return...

Страница 10: ...er elbow and one return elbow Uncommon circumstances such as neighboring hills tall trees or strong wind areas can cause down drafts in chimney system In such cases going beyond the minimum recommende...

Страница 11: ...as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 23 DO NOT NAIL THROUGH FLASHING CONE Nail Only Outer Perimeter of Flashing Storm Collar Und...

Страница 12: ...e material may be used for facing glass tile brick etc as long as proper clearances are adhered to and firebox openings are not obstructed in any way see Figure 27 Use only heat resistant noncombustib...

Страница 13: ...tween gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be...

Страница 14: ...llow flames to contact the glass Figure 31 Bi Fold Glass Doors Doors Fully Closed Firebox Front Firebox Front Doors Fully Opened Figure 30 Cabinet Glass Doors Cabinet Glass Doors WARNING FIREPLACESEQU...

Страница 15: ...d burns or clothing igni tion Young children should be carefully supervised when they are in the same room as fireplace OPERATION AND MAINTENANCE GUIDELINES Continued REPLACEMENT PARTS Note Use only o...

Страница 16: ...Not Shown PUSH ON NUT 11418 Not Shown SCREEN ROD 20806 Not Shown CHIMNEY SUPPORT 12S 8DM FIRESTOP SPACER FS 8DM DOUBLE WALL 30 ELBOW OFFSET 30E 8DM Return Elbow Starter Elbow 8 CHIMNEY PIPE ASSEMBLY 1...

Страница 17: ...WITH SLIP SECTION ETL 8DM ETLO 8DM BI FOLD GLASS DOOR DG368ST Brushed Brass DC368ST Platinum DBP368ST Black ACCESSORIES Continued OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4 ROUND TOP TERMINATION RTL 8...

Страница 18: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 19: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 20: ...design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126610 01 Rev A 12 20...