OPERATION AND MAINTENANCE GUIDELINES

GLASS DOORS

Bi-fold glass doors are optional with this fireplace. Check with your 

local distributor for availability.
To install glass doors, refer to installation instructions that are in-

cluded with kit. When fireplace is in operation, doors must be fully 

open or fully closed position only or a fire hazard may be created 

(see Figure 30 or 31).

A fireplace equipped with glass doors operates much differently 

than a fireplace with an open front. A fireplace with glass doors has 

a limited amount of air for combustion. Excessive heat within the 

fireplace can result if too large a fire is built or if combustion air gate 

is not completely open.

IMPORTANT: 

The following tips should be used to assure that both 

fireplace and glass door retain their beauty and function properly. 

• 

Both the flue damper and glass doors must be fully opened 

before starting a fire. This will provide sufficient combustion 

air and maintain safe temperatures in firebox.

• 

The glass must be allowed to warm slowly and evenly. The tem-

pered glass will withstand a gradual temperature rise to 550° F, 

which is more than a normal fire will generate. Such materials 

as pitch/wax laden logs, very dry mill end lumber and large 

amounts of paper or cardboard boxes. Always keep the fire well 

back from the doors and never allow flames to contact the glass.

Figure 31 - Bi-Fold Glass Doors

Doors Fully Closed

Firebox Front

Firebox Front

Doors

Fully Opened

Figure 30 - Cabinet Glass Doors

Cabinet 

Glass 

Doors

 " WARNING: FIREPLACES EQUIPPED WITH DOORS 

SHOULD BE OPERATED ONLY WITH DOORS FULLY 

OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT 

PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT 

OF THE FIREPLACE OPENING, CREATING RISKS OF 

BOTH FIRE AND SMOKE".

Cleaning Glass

Clean glass with any commercial glass cleaner or soap and water. 

Do not use any abrasive material to clean glass. Do not clean glass 

with any cool water if glass is still hot from the fire. To remove doors, 

refer to instructions included with glass door kit.

DAMPER MECHANISM

The damper control lever is located inside the fire chamber (see Fig-

ure 32). Make sure lever is cool before handling. Pull down to close 

and push up to open. Damper must be open when lighting a fire. 

Not doing so will cause smoke spillage into the room. When firebox 

is not in use, close damper to prevent down drafts to enter room.

GRATE

OUTSIDE AIR
HANDLE
PULL TO CLOSE
PUSH TO OPEN

DAMPER CONTROL LEVER
PULL DOWN TO CLOSE
PUSH UP TO OPEN

Figure 32 - Damper Operation

OUTSIDE AIR MECHANISM

The outside air handle is located at the right hand side of firebox 

rear refractory (see Figure 32). Pull to close, push to open. Always 

open mechanism when starting a fire. This provides adequate outside 

combustion air. Close mechanism when not in use to prevent cold 

air from entering room. Periodically check your outside air intake 

vent hood for any possible obstructions such as snow, bushes, etc.

Содержание WRT35STWSI Custom Series

Страница 1: ...e is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard...

Страница 2: ...ire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless other...

Страница 3: ...urn veryquickly DONOTusetreatedwood charcoal coal trash driftwoodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normall...

Страница 4: ...re itshallberemoved to reduce the risk of a chimney fire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or fully closed when operating fireplace WARNING Children an...

Страница 5: ...box Clearances Figure 2 Common Location of Fireplace Existing Wall Projected Wall 12 30 4 cm to Perpendicular Wall MINIMUM CLEARANCE TO COMBUSTIBLES Back and sides of fireplace 1 minimum Adjacent wall...

Страница 6: ...cm Min Clearance From Outer Pipes to Combustibles 1 2 5 cm Min To Combustibles 21 5 16 54 cm 42 5 8 108 cm 24 61 cm 12 31 cm Figure 7 Framing Firebox with Z Type Ember Protectors As Required by Desig...

Страница 7: ...ies on page 16 Avoid installing outside air eyebrow in areas where inlet opening may be blocked by snow bushes or other obstacles It should also be located beyond the reach of children CAUTION Combust...

Страница 8: ...18 36 and 48 The actual lineal gain for each is measured after each section is fully connected Lineal gain is the actual measurable length of a part after two or more parts are connected PIPE INSTALL...

Страница 9: ...wall pipe see offset chart and Figure 18 Maximum length of pipe between supports is 6 feet of angled run A Figure 18 Raise and Offset B A Screws Figure 16 Elbow Offset 30 FT 9 14m 30 FT 9 14m Return...

Страница 10: ...er elbow and one return elbow Uncommon circumstances such as neighboring hills tall trees or strong wind areas can cause down drafts in chimney system In such cases going beyond the minimum recommende...

Страница 11: ...as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 23 DO NOT NAIL THROUGH FLASHING CONE Nail Only Outer Perimeter of Flashing Storm Collar Und...

Страница 12: ...e material may be used for facing glass tile brick etc as long as proper clearances are adhered to and firebox openings are not obstructed in any way see Figure 27 Use only heat resistant noncombustib...

Страница 13: ...tween gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be...

Страница 14: ...llow flames to contact the glass Figure 31 Bi Fold Glass Doors Doors Fully Closed Firebox Front Firebox Front Doors Fully Opened Figure 30 Cabinet Glass Doors Cabinet Glass Doors WARNING FIREPLACESEQU...

Страница 15: ...d burns or clothing igni tion Young children should be carefully supervised when they are in the same room as fireplace OPERATION AND MAINTENANCE GUIDELINES Continued REPLACEMENT PARTS Note Use only o...

Страница 16: ...Not Shown PUSH ON NUT 11418 Not Shown SCREEN ROD 20806 Not Shown CHIMNEY SUPPORT 12S 8DM FIRESTOP SPACER FS 8DM DOUBLE WALL 30 ELBOW OFFSET 30E 8DM Return Elbow Starter Elbow 8 CHIMNEY PIPE ASSEMBLY 1...

Страница 17: ...WITH SLIP SECTION ETL 8DM ETLO 8DM BI FOLD GLASS DOOR DG368ST Brushed Brass DC368ST Platinum DBP368ST Black ACCESSORIES Continued OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4 ROUND TOP TERMINATION RTL 8...

Страница 18: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 19: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 20: ...design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126610 01 Rev A 12 20...

Отзывы: