background image

www.Superiorfireplaces.US.com

126610-01A

13

 WARNING: A qualified service person must con-

nect fireplace to gas supply. Follow all local codes.

A gas line may be installed for the purpose of installing a vented 

or vent-free decorative gas appliance available through your local 

distributor. Use only gas piping approved by local codes. When 

installing a gas line, a shutoff valve designed for installation outside 

the appliance is recommended.
The gas pipe is intended for connection to a decorative gas ap-

pliance that operates using natural or propane/LP gas only. This 

appliance must have an automatic shutoff device and must comply 

with the Standard for Decorative Gas Appliances for Installation in 

Vented Fireplace, ANSI Z21.60. ONLY UNVENTED GAS LOG SETS 

WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR 

UNVENTED ROOM HEATERS, ANSI Z21.11.2, ARE TO BE INSTALLED 

IN THIS FIREPLACE.

NOTICE:

 Before you proceed, make sure your gas supply is turned off.

Use only a 1/2" black iron pipe and appropriate fittings.
1.  Remove knockout indentation on refractory or firebrick wall 

located approximately 2" above the refractory hearth floor. The 

knockout indentation must be firmly tapped with any solid object 

such as a 1/2" dowel until it is released. Remove fragmented 

portions of refractory (see Figure 28).

2.  Remove gas line cover plate located on rear of fireplace and pull 

out insulation from gas line conduit sleeve. Save insulation for 

reuse.

3.  Run 1/2" black iron gas line into the firebox through the rear at 

11 1/4" from floor and through gas line conduit sleeve (if using 

a raised platform, add height). Provide sufficient gas line into 

firebox chamber for fitting connection (see Figure 29).

 

Note: 

Secure incoming gas line to wood framing to provide rigidity 

for threaded end.

4.  Repack insulation around gas line and into sleeve opening. Seal 

any gaps between gas line and refractory knockout hole with 

refractory cement or commercial furnace cement, Install the gas 

appliance or cap off gas line if desired.

 CAUTION: All gas piping and connections must be 

tested for leaks after installation is completed. After 

ensuring that gas valve is on, apply soap and water 

solution to all connections and joints. Bubbles forming 

show a leak. Correct all leaks at once. DO NOT USE 

AN OPEN FLAME FOR LEAK TESTING AND DO NOT 

OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. 

LEAK TESTING SHOULD BE DONE BY A QUALIFIED 

SERVICE PERSON.

Note: 

An IHP hood must be installed when using an unvented gas 

log set (see Accessories on page 16).

 WARNING: Do not operate an unvented gas log 

set in this fireplace with chimney removed.

Figure 29 - Gas Line Installation

OPTIONAL GAS LINE INSTALLATION

Figure 28 - Gas Line Knockout

Side 

Firebrick 

Finished 

Side

Refractory 

Knockout 

Plug

Outside of Fireplace

Gas Line 

Conduit

Insulation

Gas 

Conduit 

Cover

1/2" Dowel

Seal 

Opening 

with 

Refractory 

Cement

Outside of 

Fireplace

Gas 

Line 

Conduit

Repack 

Insulation

Incoming 

1/2" Black 

Iron Pipe

Side 

Firebrick 

Finished 

Side

Provide Enough 

Threaded End for 

Fitting Connection

If you install a decorative gas appliance (vented gas log), decorative 

gas appliance must comply with the Standard for Decorative Gas 

Appliance for Installation in Solid Fuel Burning Fireplaces, ANSI 

Z21.60/CSA 2.26 or Z21.84 and shall also be installed in accordance 

with ANSI Z223.1/NFPA 54 National Fuel Gas Codes (USA) and CAN/

CGA-B149.1 National Gas And Propane Installation Code (Canada).

 

WARNING: To avoid the risk of damaging fireplace 

materials and increasing the risk of spreading a fire, 

do not use fireplace to cook or warm food.

 WARNING: If the fireplace has been used for wood 

burning, firebox and chimney must be cleaned of soot, 

creosote and ashes be a qualified chimney cleaner. 

Creosote will ignite if heavily heated.

 WARNING: When using a decorative vented gas 

log, damper must be removed or permanently locked 

in fully open position and glass doors must be in fully 

open position.

Содержание WRT35STWSI Custom Series

Страница 1: ...e is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard...

Страница 2: ...ire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless other...

Страница 3: ...urn veryquickly DONOTusetreatedwood charcoal coal trash driftwoodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normall...

Страница 4: ...re itshallberemoved to reduce the risk of a chimney fire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or fully closed when operating fireplace WARNING Children an...

Страница 5: ...box Clearances Figure 2 Common Location of Fireplace Existing Wall Projected Wall 12 30 4 cm to Perpendicular Wall MINIMUM CLEARANCE TO COMBUSTIBLES Back and sides of fireplace 1 minimum Adjacent wall...

Страница 6: ...cm Min Clearance From Outer Pipes to Combustibles 1 2 5 cm Min To Combustibles 21 5 16 54 cm 42 5 8 108 cm 24 61 cm 12 31 cm Figure 7 Framing Firebox with Z Type Ember Protectors As Required by Desig...

Страница 7: ...ies on page 16 Avoid installing outside air eyebrow in areas where inlet opening may be blocked by snow bushes or other obstacles It should also be located beyond the reach of children CAUTION Combust...

Страница 8: ...18 36 and 48 The actual lineal gain for each is measured after each section is fully connected Lineal gain is the actual measurable length of a part after two or more parts are connected PIPE INSTALL...

Страница 9: ...wall pipe see offset chart and Figure 18 Maximum length of pipe between supports is 6 feet of angled run A Figure 18 Raise and Offset B A Screws Figure 16 Elbow Offset 30 FT 9 14m 30 FT 9 14m Return...

Страница 10: ...er elbow and one return elbow Uncommon circumstances such as neighboring hills tall trees or strong wind areas can cause down drafts in chimney system In such cases going beyond the minimum recommende...

Страница 11: ...as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 23 DO NOT NAIL THROUGH FLASHING CONE Nail Only Outer Perimeter of Flashing Storm Collar Und...

Страница 12: ...e material may be used for facing glass tile brick etc as long as proper clearances are adhered to and firebox openings are not obstructed in any way see Figure 27 Use only heat resistant noncombustib...

Страница 13: ...tween gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be...

Страница 14: ...llow flames to contact the glass Figure 31 Bi Fold Glass Doors Doors Fully Closed Firebox Front Firebox Front Doors Fully Opened Figure 30 Cabinet Glass Doors Cabinet Glass Doors WARNING FIREPLACESEQU...

Страница 15: ...d burns or clothing igni tion Young children should be carefully supervised when they are in the same room as fireplace OPERATION AND MAINTENANCE GUIDELINES Continued REPLACEMENT PARTS Note Use only o...

Страница 16: ...Not Shown PUSH ON NUT 11418 Not Shown SCREEN ROD 20806 Not Shown CHIMNEY SUPPORT 12S 8DM FIRESTOP SPACER FS 8DM DOUBLE WALL 30 ELBOW OFFSET 30E 8DM Return Elbow Starter Elbow 8 CHIMNEY PIPE ASSEMBLY 1...

Страница 17: ...WITH SLIP SECTION ETL 8DM ETLO 8DM BI FOLD GLASS DOOR DG368ST Brushed Brass DC368ST Platinum DBP368ST Black ACCESSORIES Continued OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4 ROUND TOP TERMINATION RTL 8...

Страница 18: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 19: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 20: ...design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126610 01 Rev A 12 20...

Отзывы: