background image

www.Superiorfireplaces.US.com

126607-01A

7

Figure 8 - Air Kit Installation

Figure 9- Air Kit Damper Rod

Secure to Collars with Metal Tape, Screws 

or Straps (Min. of 1/4" x 20" in size)

Air Inlet 

Location 

Must Allow 

For Bushes 

or Snow

Vent Hood 

Required for 

Wall Installation

Air Inlet 

Eyebrow

Vented Crawl Space (Check 

Local Codes Before Installing in a 

Vented Crawl Space)

VENTING INSTALLATION

OPTIONAL OUTSIDE AIR KIT (MODELS AK4 OR AK4F)

The installation of an outside air kit should be performed during 

the rough framing of the fireplace due to the nature of it’s 

location. Outside combustion air is accessed through and exterior 

wall (AK4) or a vented crawl space (AK4F). See Figure 8 and 

Accessories on page 16.

Avoid installing outside air eyebrow in areas where inlet opening 

may be blocked by snow, bushes or other obstacles. It should also 

be located beyond the reach of children.

 CAUTION: Combustion air inlet ducts shall not 

terminate in attic space.

The maximum height for the air vent can not exceed 

3 feet below the flue gas outlet of the termination.

For further details on installation of outside air kit, please refer to 

instructions included with air kit. For operating instructions, please 

refer to your owner’s manual.

Outside air handle is located on left-hand side of fireplace refractory 

(see Figure 9, Model WRT40CRWSI shown). To close, pull down; 

to open, push up. Always open mechanism when starting a fire to 

provide adequate outside combustion air. Close mechanism when 

not in use to prevent cold air from entering room.

Air Kit 

Damper 

Rod- 

Closed 

Position

Open 

Position

Lower Left Side 

of Fireplace 

Opening

CHIMNEY SYSTEM
Chimney height 

Minimum chimney height measured fro bottom of fireplace to flue 

gas outlet-end of termination is:
Straight run 

 

14 feet

Run with one elbow set   15 feet
Run with two elbow sets  24 feet
An elbow set consists of one starter elbow and one return elbow. 

Uncommon circumstances such as neighboring hills, tall trees, or 

strong wind areas can cause downdrafts in chimney system. In 

such cases, going beyond minimum recommended height would 

be preferable to provide a better draw.
Maximum height approved for any chimney run with this fireplace 

system is 60 feet as measured from fireplace bottom to flue outlet 

end of termination.

Double Wall Chimney System

An IHP chimney system consists of 12", 18", 24", 36" and 48" snap-

lock, double-wall pipe segments, planned for maximum adaptability 

to individual site requirements. Actual lengths gained after fitting 

overlaps must be taken into consideration (lineal gain) and are given 

in lineal gain chart (see Figure 10, page 8).
Lineal gain is actual measurable length of a part after two or more 

parts are connected.
Each double wall chimney section consists of a galvanized outer pipe, 

a stainless steal inner flue pipe and a wire spacer. Pipe sections must 

be assembled independently as chimney is installed. When connecting 

chimney directly to fireplace, inner flue pipe section must be installed 

first with lanced (female) side up (see Figure 10, page 8). Outer pipe 

section can then be installed over flue pipe section with hemmed (male) 

end up. Press down on each pipe section until lances securely engage 

hem on fireplace starter. The wire will assure proper spacing between 

inner and outer pipe sections.
Continue to assemble chimney sections as outlined above, making 

sure both inner and outer pipe sections are locked together. 
When installing double wall snap-lock chimney together, it is impor-

tant to assure the joint between chimney sections is locked. Check by 

pulling chimney upward after locking. Chimney will not come apart if 

properly locked. It is not necessary to add screws to keep chimney 

together. However, if desired, use screws per directions provided 

on page 8, Figure 11.
Note: For Canada, use chimney parts designated HT.

Содержание WCT40CLWSI

Страница 1: ...r use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard An INNOVATIVE HE...

Страница 2: ...ponents are safe when installed according to this installation manual Unless you use IHP com ponents which have been designed and tested for the fireplace system you may cause a fire hazard The IHP wa...

Страница 3: ...to treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxi...

Страница 4: ...WARNING Children and adults should be alerted to the hazards of high surface temperatures and to stay away to avoid burns or clothing ignition Young children should be carefully supervised when in the...

Страница 5: ...1 2 minimum WARNING DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS Do not obstruct fireplace openings ie louvers etc with any type of facing material Combustible mate rial must no...

Страница 6: ...such as tile slate brick concrete metal glass marble stone etc Provide a means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a non combustib...

Страница 7: ...n with two elbow sets 24 feet An elbow set consists of one starter elbow and one return elbow Uncommon circumstances such as neighboring hills tall trees or strong wind areas can cause downdrafts in c...

Страница 8: ...5 8 18 8DM Pipe Section 16 5 8 24 8DM Pipe Section 23 5 8 36 8DM Pipe Section 34 5 8 48 8DM Pipe Section 46 5 8 RT 8DM Round Termination 6 7 8 RTL 8DM Round Termination 7 3 4 RTT 8DM Round Termination...

Страница 9: ...oint where the chimney pen etrates a floor or ceiling joist space Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials When the pipe pass...

Страница 10: ...e 16 This support is designed to relieve extra weight load on fireplace and elbows when high chimneys are installed Figure 16 Support Sections 30 FT 30 FT 12S 8DM Support Return Elbow Effective Height...

Страница 11: ...upport wires may be at tachedtoouterpipeofchimneywithscrewsprovided screws do not penetrate inner flue pipe Figure 20 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing FLASHING INSTALLA...

Страница 12: ...manufac turer for specifications 10 FOOT RULE All chimney terminations must extend a minimum of 3 above the highest point where it passes through the roof and must be at least 2 above roof with a 10...

Страница 13: ...gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be teste...

Страница 14: ...ng a fireplace system in a cold climate area Following these steps will aid in reducing cold air infiltration from fireplace enclosure into living space 1 Fireplace must be placed on a solid continuou...

Страница 15: ...S OF BOTH FIRE AND SMOKE OPERATION AND MAINTENANCE GUIDELINES Continued Cleaning Glass Clean glass with any commercial glass cleaner or soap and water Do not use any abrasive material to clean glass D...

Страница 16: ...ft 20128 Right SCREEN 12111 Not Shown PUSH ON NUT 11418 Not Shown SCREEN ROD 20806 Not Shown CHIMNEY SUPPORT 12S 10DM FIRESTOP SPACER FS 8DM DOUBLE WALL 30 ELBOW OFFSET 30E 8DM Return Elbow Starter El...

Страница 17: ...N ETL 8DM ETLO 8DM BI FOLD GLASS DOOR VDBP36C Black VDG36C Brushed Brass DC36L R LS RS Platinum ACCESSORIES Continued FAN KIT VCBK4C LEFT VCBK4R RIGHT OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION AK4F O...

Страница 18: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 19: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 20: ...design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126607 01 Rev A 12 20...

Отзывы: