Superior WCT40CLWSI Скачать руководство пользователя страница 15

www.Superiorfireplaces.US.com

126607-01A

15

Figure 28- Glass Doors

GLASS DOORS

Bi-fold glass doors are optional with this fireplace. Check with your 

local distributor for availability.
To install glass doors, refer to installation instructions that are in-

cluded with kit. When fireplace is in operation, doors must be fully 

open or fully closed position only or a fire hazard may be created 

(see Figure 28).
A fireplace equipped with glass doors operates much differently 

than a fireplace with an open front. A fireplace with glass doors has 

a limited amount of air for combustion. Excessive heat within the 

fireplace can result if too large a fire is built or if combustion air gate 

is not completely open.
IMPORTANT: The following tips should be used to assure that both 

fireplace and glass door retain their beauty and function properly. 
•  Both the flue damper and glass doors must be fully opened 

before starting a fire. This will provide sufficient combustion 

air and maintain safe temperatures in firebox.

•  The glass must be allowed to warm slowly and evenly. The tem-

pered glass will withstand a gradual temperature rise to 550° F, 

which is more than a normal fire will generate. Such materials 

as pitch/wax laden logs, very dry mill end lumber and large 

amounts of paper or cardboard boxes. Always keep the fire well 

back from the doors and never allow flames to contact the glass.

 " WARNING: FIREPLACES EQUIPPED WITH DOORS 

SHOULD BE OPERATED ONLY WITH DOORS FULLY 

OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT 

PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT 

OF THE FIREPLACE OPENING, CREATING RISKS OF 

BOTH FIRE AND SMOKE".

OPERATION AND MAINTENANCE GUIDELINES 

Continued

Cleaning Glass

Clean glass with any commercial glass cleaner or soap and water. 

Do not use any abrasive material to clean glass. Do not clean glass 

with any cool water if glass is still hot from the fire. To remove doors, 

refer to instructions included with glass door kit.

Doors Fully Closed

Doors Fully Opened

Fireplace Front

Fireplace Front

GRATE

The grate is designed to provide you with the maximum solid fuel 

capacity. Do not overload grate or obstruct required air space beneath 

it. Always keep ashes from building up under grate.

 WARNING: Risk of fire! Replace grate made for 

use with this fireplace only. See 

Replacement Parts.

CHIMNEY

Have your chimney system cleaned and inspected regularly to ensure safe 

and efficient operation.
For further operating guidelines, instructions and warranty informa-

tion, please refer to your homeowner's guide or contact your dealer.

REPLACEMENT PARTS

Note: Use only original replacement parts.

This will protect your warranty coverage for parts replaced under 

warranty.

Contact authorized dealers of this product. To locate a dealer in your 

area contact IHP at 1-800-655-2008. You can also visit our web site 

at www.Superiorfireplaces.US.com.

When calling your dealer, have ready:

•  your name

•  your address

•  model and serial numbers of your fireplace

•  how fireplace was malfunctioning

•  purchase date

Usually, we require that the part is returned to the factory.

TECHNICAL SERVICE

You may have further questions about installation, operation, or 

troubleshooting. Please contact your IHP dealer for any questions 

or concerns a. When calling your dealer please have your model and 

serial numbers of your fireplace ready. You can also visit our web 

site at www.Superiorfireplaces.US.com.

Содержание WCT40CLWSI

Страница 1: ...r use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard An INNOVATIVE HE...

Страница 2: ...ponents are safe when installed according to this installation manual Unless you use IHP com ponents which have been designed and tested for the fireplace system you may cause a fire hazard The IHP wa...

Страница 3: ...to treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxi...

Страница 4: ...WARNING Children and adults should be alerted to the hazards of high surface temperatures and to stay away to avoid burns or clothing ignition Young children should be carefully supervised when in the...

Страница 5: ...1 2 minimum WARNING DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS Do not obstruct fireplace openings ie louvers etc with any type of facing material Combustible mate rial must no...

Страница 6: ...such as tile slate brick concrete metal glass marble stone etc Provide a means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a non combustib...

Страница 7: ...n with two elbow sets 24 feet An elbow set consists of one starter elbow and one return elbow Uncommon circumstances such as neighboring hills tall trees or strong wind areas can cause downdrafts in c...

Страница 8: ...5 8 18 8DM Pipe Section 16 5 8 24 8DM Pipe Section 23 5 8 36 8DM Pipe Section 34 5 8 48 8DM Pipe Section 46 5 8 RT 8DM Round Termination 6 7 8 RTL 8DM Round Termination 7 3 4 RTT 8DM Round Termination...

Страница 9: ...oint where the chimney pen etrates a floor or ceiling joist space Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials When the pipe pass...

Страница 10: ...e 16 This support is designed to relieve extra weight load on fireplace and elbows when high chimneys are installed Figure 16 Support Sections 30 FT 30 FT 12S 8DM Support Return Elbow Effective Height...

Страница 11: ...upport wires may be at tachedtoouterpipeofchimneywithscrewsprovided screws do not penetrate inner flue pipe Figure 20 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing FLASHING INSTALLA...

Страница 12: ...manufac turer for specifications 10 FOOT RULE All chimney terminations must extend a minimum of 3 above the highest point where it passes through the roof and must be at least 2 above roof with a 10...

Страница 13: ...gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be teste...

Страница 14: ...ng a fireplace system in a cold climate area Following these steps will aid in reducing cold air infiltration from fireplace enclosure into living space 1 Fireplace must be placed on a solid continuou...

Страница 15: ...S OF BOTH FIRE AND SMOKE OPERATION AND MAINTENANCE GUIDELINES Continued Cleaning Glass Clean glass with any commercial glass cleaner or soap and water Do not use any abrasive material to clean glass D...

Страница 16: ...ft 20128 Right SCREEN 12111 Not Shown PUSH ON NUT 11418 Not Shown SCREEN ROD 20806 Not Shown CHIMNEY SUPPORT 12S 10DM FIRESTOP SPACER FS 8DM DOUBLE WALL 30 ELBOW OFFSET 30E 8DM Return Elbow Starter El...

Страница 17: ...N ETL 8DM ETLO 8DM BI FOLD GLASS DOOR VDBP36C Black VDG36C Brushed Brass DC36L R LS RS Platinum ACCESSORIES Continued FAN KIT VCBK4C LEFT VCBK4R RIGHT OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION AK4F O...

Страница 18: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 19: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 20: ...design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126607 01 Rev A 12 20...

Отзывы: