SAFETY

 Continued

 WARNING: CONTINUED OVERFIRING CAN PER-

MANENTLY DAMAGE YOUR FIREPLACE SYSTEM. 

SOME EXAMPLES OF CONDITIONS THAT COULD 

CAUSE OVERFIRING ARE:

•  BURNING QUANTITIES OF SCRAP LUMBER, PINE 

BRANCHES,  PAPER  OR  CARDBOARD  BOXES 

WHICH EXCEED THE VOLUME OF THE NORMAL 

LOG FIRE.

•  BURNING TRASH, CHEMICALS OR CHEMICALLY 

TREATED COMBUSTIBLES.

"Disposal of Ashes 
Ashes should be placed in a metal container with a 

tight-fitting lid. The closed container of ashes should 

be placed on a noncombustible floor or on the ground, 

well away from all combustible materials, pending 

final disposal. If the ashes are disposed of by burial 

in soil or otherwise locally dispersed, they should be 

retained in the closed container until all cinders have 

thoroughly cooled."

"WHEN USING THE DECORATIVE APPLIANCE, THE 

FIREPLACE DAMPER MUST BE SET IN THE FULLY 

OPEN POSITION."

"Never use gasoline, gasoline-type lantern fuel, kero-

sene, charcoal lighter fluid, or similar liquids to start 

or ’freshen up’ a fire in this fireplace. Keep all such 

liquids well away from the fireplace while it is in use."

Use SOLID WOOD only for fuel. It is best to use dry 

and well seasoned hardwood. Softwoods tend to burn 

very quickly. DO NOT use treated wood, charcoal, coal, 

trash, driftwood or woods that have been dipped in tar, 

pitch, pine tar, creosote, etc. Wood products made 

with synthetic binders, such as plywood, produce ab-

normally high temperatures and sputtering, smoking 

fires. When burning artificial logs, please read and 

follow the instructions provided by the manufacturer.

Never burn treated construction lumber or scraps. 

These woods burn excessively hot and may contain 

chemicals used to treat insects and fungus. When 

burned, these chemicals can pose a significant hazard.

 WARNING: BURNING IMPROPER FUEL (I.E. 

CHARCOAL) CAN RESULT IN CARBON MONOXIDE 

POISONING, WHICH MAY LEAD TO DEATH! 
Carbon Monoxide Poisoning – Early signs of carbon 

monoxide poisoning resemble the flu with headaches, 

dizziness, or nausea. If you have these signs, get 

fresh air at once!  Have the appliance inspected by a 

qualified service technician.  Some people are more 

affected by carbon monoxide than others.  These 

include pregnant women, people with heart or lung 

disease or anemia, those under the influence of al-

cohol, and those at high altitudes.

Ventilation Requirements - Provide adequate air for 

combustion. The fresh air requirements of this ap-

pliance must be met within the space where it will 

be installed.

Smoke Detectors - Since there are always several 

potential sources of fire in any home, we recommend 

installing smoke detectors. If possible, install the 

smoke detector in a hallway adjacent to the room (to 

reduce the possibility of occasional false activation 

from the heat produced by the appliance).  If your local 

code requires a smoke detector be installed within the 

same room, you must follow the requirements of your 

local code. Check with your local building department 

for requirements in your area.

"Creosote – Formation and Need for Removal 

When wood is burned slowly, it produces tar and other 

organic vapors, which combine with expelled moisture 

to form creosote. The creosote vapors condense in 

the  relatively  cool  chimney  flue  of  a  slow-burning 

fire. As a result, creosote residue accumulates on 

the flue lining. When ignited this creosote makes an 

extremely hot fire. 

The chimney shall be inspected at least twice a 

year during the heating season to determine when a 

creosote buildup has occurred.  When creosote has 

accumulated (1/8" [3 mm] or more) it shall be removed 

to reduce the risk of a chimney fire."

Содержание WCT40CLWSI

Страница 1: ...r use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard An INNOVATIVE HE...

Страница 2: ...ponents are safe when installed according to this installation manual Unless you use IHP com ponents which have been designed and tested for the fireplace system you may cause a fire hazard The IHP wa...

Страница 3: ...to treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxi...

Страница 4: ...WARNING Children and adults should be alerted to the hazards of high surface temperatures and to stay away to avoid burns or clothing ignition Young children should be carefully supervised when in the...

Страница 5: ...1 2 minimum WARNING DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS Do not obstruct fireplace openings ie louvers etc with any type of facing material Combustible mate rial must no...

Страница 6: ...such as tile slate brick concrete metal glass marble stone etc Provide a means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a non combustib...

Страница 7: ...n with two elbow sets 24 feet An elbow set consists of one starter elbow and one return elbow Uncommon circumstances such as neighboring hills tall trees or strong wind areas can cause downdrafts in c...

Страница 8: ...5 8 18 8DM Pipe Section 16 5 8 24 8DM Pipe Section 23 5 8 36 8DM Pipe Section 34 5 8 48 8DM Pipe Section 46 5 8 RT 8DM Round Termination 6 7 8 RTL 8DM Round Termination 7 3 4 RTT 8DM Round Termination...

Страница 9: ...oint where the chimney pen etrates a floor or ceiling joist space Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials When the pipe pass...

Страница 10: ...e 16 This support is designed to relieve extra weight load on fireplace and elbows when high chimneys are installed Figure 16 Support Sections 30 FT 30 FT 12S 8DM Support Return Elbow Effective Height...

Страница 11: ...upport wires may be at tachedtoouterpipeofchimneywithscrewsprovided screws do not penetrate inner flue pipe Figure 20 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing FLASHING INSTALLA...

Страница 12: ...manufac turer for specifications 10 FOOT RULE All chimney terminations must extend a minimum of 3 above the highest point where it passes through the roof and must be at least 2 above roof with a 10...

Страница 13: ...gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be teste...

Страница 14: ...ng a fireplace system in a cold climate area Following these steps will aid in reducing cold air infiltration from fireplace enclosure into living space 1 Fireplace must be placed on a solid continuou...

Страница 15: ...S OF BOTH FIRE AND SMOKE OPERATION AND MAINTENANCE GUIDELINES Continued Cleaning Glass Clean glass with any commercial glass cleaner or soap and water Do not use any abrasive material to clean glass D...

Страница 16: ...ft 20128 Right SCREEN 12111 Not Shown PUSH ON NUT 11418 Not Shown SCREEN ROD 20806 Not Shown CHIMNEY SUPPORT 12S 10DM FIRESTOP SPACER FS 8DM DOUBLE WALL 30 ELBOW OFFSET 30E 8DM Return Elbow Starter El...

Страница 17: ...N ETL 8DM ETLO 8DM BI FOLD GLASS DOOR VDBP36C Black VDG36C Brushed Brass DC36L R LS RS Platinum ACCESSORIES Continued FAN KIT VCBK4C LEFT VCBK4R RIGHT OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION AK4F O...

Страница 18: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 19: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 20: ...design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126607 01 Rev A 12 20...

Отзывы: