Superior WCT3036RH Скачать руководство пользователя страница 8

SuperiorFireplaces.us.com

126619-01_K

8

Figure 8 - Lineal Gain

Hemmed 

End

8" Stainless 

Inner Pipe

12 

3

/

8

Galvanized 

Outer Pipe

 WARNING: The opening in collar around chimney 

at top of fireplace must not be obstructed. Never use 

blown insulation to fill chimney enclosure

.

LINEAL GAIN

CAT. NO. PART NO.

DESCRIPTION

GAIN

36"

Fireplace

37 

1

/

2

"

F0895

F0881

12-8DM

12-8HT

Pipe Section

10 

5

/

8

"

F0896

F0882

18-8DM

18-8HT

Pipe Section

16 

5

/

8

"

F0897

F0883

24-8DM

24-8HT

Pipe Section

23 

5

/

8

"

F0898

F0884

36-8DM

36-8HT

Pipe Section

34 

5

/

8

"

F0899

F0885

48-8DM

48-8HT

Pipe Section

46 

5

/

8

"

F0916

RT-8DM

Round Termination

7

/

8

"*

RTL-8DM

Round Termination

3

/

4

"*

F0918

RLT-8DM

Round Termination

1

/

2

"*

F0917

RTT-8DM

Round Termination with 

Slip Section

7

/

8

" to 

23 

1

/

8

"*

RTTL-8DM

Round Termination with 

Slip Section

1

/

2

" to  

21 

1

/

2

"*

F0919

RLTT-8DM

Round Termination with 

Slip Section

1

/

2

" to  

21 

1

/

4

"*

F0920

ET-8DM

Square Chase-Top

12"*

F0922

ETO-8DM

Square Chase-Top with 

Mesh

12"*

F0921

ETL-8DM

Square Chase-Top with 

Slip Section

7" to 15"*

F0923

ETLO-8DM

Square Chase-Top with 

Mesh & Slip Section

12" to  

25 

1

/

2

"*

* The lineal gain for the terminations is measured to the flue 

gas outlet height.

VENTING INSTALLATION 

Continued

ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY 

SYSTEM

Each double wall chimney section consists of a galvanized outer 

pipe, a stainless steel inner flue pipe and a wire spacer. Pipe sections 

must be assembled independently as chimney is installed. When 

connecting chimney directly to fireplace, inner flue pipe section 

must be installed first with lanced side up. Outer pipe section can 

then be installed over flue pipe section with hemmed end up. Press 

down on each pipe section until lances securely engage hem on 

fireplace starter. Wire will assure proper spacing between inner 

and outer pipe sections.

Note:

 For Canada, use chimney parts designated HT.

Continue to assemble chimney sections as outlined, making sure 

that both inner and outer pipe sections are locked together. When 

installing double wall snap-lock chimney together, it is important to 

assure joint between chimney sections is locked. Check by pulling 

chimney upward after locking. Chimney will not come apart if properly 

locked. It is not necessary to add screws to keep chimney together 

(exception - see Figure 11, page 10).
The height of a vertical chimney pipe supported 

ONLY

 by the fireplace, 

must not exceed 20 feet. Chimney heights above 20 feet must be 

supported.

USING ELBOW OFFSETS (30E-8DM)

1.  To achieve desired offset, you may install combinations of 12", 

18", 24", 36" and 48" length of double wall pipe (see offset chart, 

page 10, and Figure 9, page 9).

 

Note:

 For systems with 2 elbow sets, minimum height is 22 feet. 

Maximum height for any system is 50 feet.

2.  Chimney weight above offset rests on return elbow. Straps must 

be securely nailed to rafters or joists (see Figure 10, details A and 

B, page 9).

3.  Maximum length of pipe between supports (return elbow or 12S-

8DM) is 6' of angle run. Maximum of two 6' angle run sections 

per chimney system (see Figure 9, page 9).

4.  All pipe connections between offset and return must be secured 

with two screws on outer pipe only (see Figure 11, page 10). Do 

not penetrate inner stainless.

Содержание WCT3036RH

Страница 1: ...age 20 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR...

Страница 2: ...tested for the fireplace system you may cause a fire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace componen...

Страница 3: ...nposeasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESUL...

Страница 4: ...8 232 mm 3 1 2 89 mm 3 1 2 89 mm 11 1 2 292 mm 22 559 mm 29 737 mm 41 1042 mm 1 26 mm 1 26 mm 21 534 mm 8 204 mm 35 889 mm 37 940 mm 41 1042 mm 1 26 mm AIRSPACE TO COMBUSTIBLE MATERIAL 0 0 mm TO TOP S...

Страница 5: ...nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth exten...

Страница 6: ...ss than 12 from top opening of fireplace NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material also may come up to side edge of black metal face of fireplace a...

Страница 7: ...ttic space The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination CHIMNEY PIPE WARNING Label part number 900599 01 must be applied by the installer to a...

Страница 8: ...e inner flue pipe section must be installed first with lanced side up Outer pipe section can then be installed over flue pipe section with hemmed end up Press down on each pipe section until lances se...

Страница 9: ...Support Pipe 12S 8DM 1 26 mm Min Straps Straps Straps Straps Detail A Return Elbow Detail B Angle Firestop See Detail A See Detail B Ceiling Support Pipe 12S 8DM VENTING INSTALLATION Continued Offset...

Страница 10: ...n Figure 13 Figure 12 Firestop Spacer with Living Space Above Ceiling Figure 13 Firestop Spacer with Attic Space Above Ceiling If area above is a living space install firestop below framed hole If are...

Страница 11: ...a tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Fireplace syst...

Страница 12: ...als such as wallboard sheet rock drywall ply wood etc may make direct contact with sides and top around fire place face It is important that combustible materials do not overlap face itself Brick glas...

Страница 13: ...ent Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Страница 14: ...ss doors operates much differently than a fireplace with an open front A fireplace with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too large a...

Страница 15: ...used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the...

Страница 16: ...TS WOOD BURNING FIREPLACE MODELS MODEL CATALOG NO WRT3036WS F0659 WRT3036WSI F0660 WRT3036WH F0661 WCT3036WS F0662 WCT3036WSI F0663 WCT3036WH F0664 9 4 28 29 19 12 20 26 17 8 1 5 21 2 30 18 11 14 3 13...

Страница 17: ...mper Can Collar 1 16 J8007 Screen Assembly Kit 1 17 Firebox Top Assembly 1 18 Air Kit Door Assembly 1 19 Face Weldment 1 20 J3991 Smoke Deflector 1 21 Fireplace Top Insulation 1 22 Access Panel 1 23 J...

Страница 18: ...ight Stacked White 1 4 Refractory Rear Stacked White 1 5 Refractory Bottom Rear White 1 6 Refractory Bottom Front White 1 WARNING Contact an IHP dealer to obtain any of these parts Never use substitut...

Страница 19: ...HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp D...

Страница 20: ...Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square To...

Страница 21: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...

Страница 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Страница 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Страница 24: ...6619 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Отзывы: