Superior WCT3036RH Скачать руководство пользователя страница 15

SuperiorFireplaces.us.com

126619-01_K

15

Figure 25 - Locating Access Cover Plate

Access Panel

LOCATING ACCESS COVER PLATE

Sheet metal cover plates located underneath front hearth refractory may 

have shifted or moved out of place while fireplace was in transit. These 

cover plates must be kept in the proper location prior to using the fireplace 

(See Figure 25). 
For further operating guidelines, instructions and warranty informa-

tion, please refer to your homeowner's guide or contact your dealer.

REPLACEMENT PARTS

See Pages 16 to 18 for a complete replacement parts list. Use only 

parts supplied from the manufacturer.
Normally, all parts should be ordered through your IHP distributor 

or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The model number of the fireplace.

2. The serial number of the fireplace.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the fireplace.
If you encounter any problems or have any questions concerning the 

installation or application of this fireplace, please contact your dealer.

IHP

1769 East Lawrence Street

Russellville, AL 35654

Visit us at SuperiorFireplaces.us.com

TECHNICAL SERVICE

You may have further questions about installation, operation, or 

troubleshooting. Please contact your IHP dealer for any questions 

or concerns. When contacting your dealer please have your model 

and serial numbers of your fireplace ready. You can also visit our 

web site at SuperiorFireplaces.us.com.

OPERATION AND MAINTENANCE  

Continued

IMPORTANT NOTICE

A manufactured shroud which has been approved by a 

national testing agency for use with this fireplace may 

be used if installed in accordance with the instructions 

by its manufacturer. A locally fabricated shroud may be 

used with IHP Shroud Leg Spacer Kit (SLK) in accor-

dance with instructions provided with the shroud.

NOTICE: The firebox canopy (hood) must not be modified 

or replaced with a canopy that may be provided with the 

unvented decorative room heater.

CAUTION: THE STRUCTURAL INTEGRITY OF THE MANU-

FACTURED HOME FLOOR, WALL, AND CEILING/ROOF 

MUST BE MAINTAINED.

 

 

WARNING: DO NOT INSTALL IN SLEEPING ROOM OF 

MOBILE HOMES.

IMPORTANT NOTICES - CANADA

Canadian code CAN/ULC-S610-M87 and other pertinent codes require stain-

less steel chimney for the installation of this fireplace. A Cold Air Climate 

Kit is also required in Canada and is recommended for cooler regions in the 

United States. Below, find a list of approved stainless steel parts.

Chimney Parts List for Canada

Catalog 

No.

Model No. 8" Hi-Temp  

Wood burning Chimney

F0881

12-8HT

12" Section Hi-Temp Double Wall Pipe Snap Lock

F0882

18-8HT

18" Section Hi-Temp Double Wall Pipe Snap Lock

F0883

24-8HT

24" Section Hi-Temp Double Wall Pipe Snap Lock

F0884

36-8HT

36" Section Hi-Temp Double Wall Pipe Snap Lock

F0885

48-8HT

48" Section Hi-Temp Double Wall Pipe Snap Lock

F0886

30E-8HT

30 Degree Hi-Temp Offset and Return

F0887

12S-8HT

Hi-Temp Chimney Support (For Use With Chimney 

Heights In Excess of 30')

F0888

RT-8HT

Hi-Temp Round Top with Mesh Screen

F0889

RTT-8HT*

Hi-Temp Round Top with Mesh Screen and Slip 

Section

F0890

RLT-8HT

Hi-Temp Round Top with Louvered Screen

F0891

RLTT-8HT* Hi-Temp Round Top with Louvered Screen and 

Slip Section

F0892

ET-8HT*

Hi-Temp Pyramid Top with Slip Section

F0893

ETL-8HT*

Hi-Temp Large Pyramid Top with Slip Section (use 

with all 8" systems)

F0894

AP-8HT

Hi-Temp Anchor Plate/Collar Assembly (for ma-

sonry fireplaces)

F0929

CAK-8

Cold Air Collar Kit - 8" Chimney

*When ordered alone, this part cannot ship via parcel delivery services.

Содержание WCT3036RH

Страница 1: ...age 20 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR...

Страница 2: ...tested for the fireplace system you may cause a fire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace componen...

Страница 3: ...nposeasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESUL...

Страница 4: ...8 232 mm 3 1 2 89 mm 3 1 2 89 mm 11 1 2 292 mm 22 559 mm 29 737 mm 41 1042 mm 1 26 mm 1 26 mm 21 534 mm 8 204 mm 35 889 mm 37 940 mm 41 1042 mm 1 26 mm AIRSPACE TO COMBUSTIBLE MATERIAL 0 0 mm TO TOP S...

Страница 5: ...nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth exten...

Страница 6: ...ss than 12 from top opening of fireplace NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material also may come up to side edge of black metal face of fireplace a...

Страница 7: ...ttic space The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination CHIMNEY PIPE WARNING Label part number 900599 01 must be applied by the installer to a...

Страница 8: ...e inner flue pipe section must be installed first with lanced side up Outer pipe section can then be installed over flue pipe section with hemmed end up Press down on each pipe section until lances se...

Страница 9: ...Support Pipe 12S 8DM 1 26 mm Min Straps Straps Straps Straps Detail A Return Elbow Detail B Angle Firestop See Detail A See Detail B Ceiling Support Pipe 12S 8DM VENTING INSTALLATION Continued Offset...

Страница 10: ...n Figure 13 Figure 12 Firestop Spacer with Living Space Above Ceiling Figure 13 Firestop Spacer with Attic Space Above Ceiling If area above is a living space install firestop below framed hole If are...

Страница 11: ...a tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Fireplace syst...

Страница 12: ...als such as wallboard sheet rock drywall ply wood etc may make direct contact with sides and top around fire place face It is important that combustible materials do not overlap face itself Brick glas...

Страница 13: ...ent Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Страница 14: ...ss doors operates much differently than a fireplace with an open front A fireplace with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too large a...

Страница 15: ...used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the...

Страница 16: ...TS WOOD BURNING FIREPLACE MODELS MODEL CATALOG NO WRT3036WS F0659 WRT3036WSI F0660 WRT3036WH F0661 WCT3036WS F0662 WCT3036WSI F0663 WCT3036WH F0664 9 4 28 29 19 12 20 26 17 8 1 5 21 2 30 18 11 14 3 13...

Страница 17: ...mper Can Collar 1 16 J8007 Screen Assembly Kit 1 17 Firebox Top Assembly 1 18 Air Kit Door Assembly 1 19 Face Weldment 1 20 J3991 Smoke Deflector 1 21 Fireplace Top Insulation 1 22 Access Panel 1 23 J...

Страница 18: ...ight Stacked White 1 4 Refractory Rear Stacked White 1 5 Refractory Bottom Rear White 1 6 Refractory Bottom Front White 1 WARNING Contact an IHP dealer to obtain any of these parts Never use substitut...

Страница 19: ...HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp D...

Страница 20: ...Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square To...

Страница 21: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...

Страница 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Страница 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Страница 24: ...6619 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...