background image

2

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Gas

Orifice

Type

Size

Elevation

0 - 4500'

(0 - 1370 m)

0 - 4500'

(0 - 1370 m)

Natural

Propane

(0.065)

#36

(0.106)

TABLE OF CONTENTS

Introduction ..................................... page

2

General Information ......................... page

2

Operation/Care of Your Appliance .... page

3

Damper & Outside Air Controls ....... page

4

Manual Limit Switch ........................ page

5

Maintenance .................................... page

6

Millivolt Appliance Checkout ............ page

6

Electronic Appliance Checkout ......... page

6

Maintenance Schedule ..................... page

7

Log and Rockwool Placement ......... page

8

Wiring Diagrams .............................. page

9

Lighting Instructions – Millivolt ....... page 10

Lighting Instructions – Electronic .... page 12

Troubleshooting Guide – Millivolt ..... page 14

Troubleshooting Guide – Electronic .. page 15

Warranty .......................................... page 16

Product Reference Information ....... page 16

Replacement Parts .......................... page 16

Accessory Components ................... page 17

Replacement Parts List ..................... page 18

WARNING:  IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE.  REFER TO
THIS MANUAL.  FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT
A QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.

These appliances are designed to operate on
natural or propane gas only. The use of other
fuels or combination of fuels will degrade the
performance of this system and may be dan-
gerous.

Input of appliance is 30,000 BTU/HR.

WARNING:  THESE FIREPLACES ARE
VENTED DECORATIVE GAS APPLI-
ANCES.  DO NOT BURN WOOD OR OTHER
MATERIAL IN THESE APPLIANCES.

CONGRATULATIONS!

In selecting this SUPERIOR B-vented gas appliance you have chosen the finest and most
dependable fireplace to be found anywhere.  A beautiful, prestigious, alternative to a
wood burning fireplace.  Welcome to a Family of tens of thousands of satisfied
SUPERIOR Fireplace Owners.

Please read and carefully follow all of the instructions found in this manual.  Please pay
special attention to the safety instructions provided in this manual.  The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your SUPERIOR product.

INTRODUCTION

The millivolt appliances are designed to oper-
ate on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
provides safe, efficient operation.

The electronic appliances are designed to op-
erate on either natural or propane gas. An
electronic direct spark ignition system pro-
vides safe, efficient operation. External electri-
cal power is required to operate these units.

GENERAL INFORMATION

Note: 

Installation and repair should be per-

formed by a qualified service person. The appli-
ance should be inspected annually by a quali-
fied professional service technician. More fre-
quent inspections and cleanings may be re-
quired due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating
air passage ways of the appliance be kept clean.

S'assurer que le brùleur et le compartiment
des commandes sont propres.  Voir les in-
structions d'installation et d'utilisation qui
accompagnent l'apareil.

Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.

Due to high temperatures the appliance should
be located out of traffic and away from furni-
ture and draperies.  Locate furniture and win-
dow coverings accordingly.

Nominal operating pressures for the manifold
side of the gas control system are; 3.5 inches
water column (0.87 kPa) for natural gas mod-
els and 10 inches water column (2.49 kPa) for
propane gas models.

Do not use these appliances if any part has
been under water. Immediately call a qualified,
professional service technician to inspect the
appliance and to replace any parts of the
control system and any gas control which
have been under water.

Ne pas se servir de cet appareil s'il a été
plongé dans l'eau, complètement ou en partie.
Appeler un technicien qualifié pour inspecter
l'appareil et remplacer toute partie du système
de contrôle et toute commande qui ont été
plongés dans l'leau.

These appliances comply with National Safety
Standards and are tested and listed by War-
nock Hersey (Report No. J99025850) to ANSI
Z21.50 - 2000 (in Canada, CSA 2.22 - 2000),
and CAN/CGA-2.17-M91 in both USA and
Canada, as vented gas fireplaces.

Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas
Code, ANSI Z223.1 (NFPA 54). (In Canada, the
current CAN/CGA B149 installation code.)  Elec-
trical wiring must  comply with local codes.  In
the absence of local codes, installation must
be in accordance with the National Electrical
Code, NFPA 70 - (latest edition). (In Canada,
the current CSA C22.1 Canadian Electric Code.)

DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.

Содержание STANDARD SERIES and

Страница 1: ...LO SION MAY RESULT CAUSING PROPERTY DAM AGE PERSONAL INJURY OR LOSS OF LIFE POURVOTRES CURIT Nepasentreposerniutiliser d essencenid autrevapeursouliquidesinflammables dans le voisinage de cet appareil...

Страница 2: ...vides safe efficient operation External electri cal power is required to operate these units GENERAL INFORMATION Note Installation and repair should be per formedbyaqualifiedserviceperson Theappli an...

Страница 3: ...SURED ENVIRONMENTS PRESSUREWITHINTHEHOMEISLESS THAN PRESSURES OUTSIDE SIGNIFI CANT NEGATIVELY PRESSURED ENVI RONMENTS CAUSED BY WEATHER HOME DESIGN OR OTHER DEVICES MAYIMPACTTHEOPERATIONOFTHESE APPLIA...

Страница 4: ...pliance area clear and free from combustible materials gasoline and other flammable liquids Honeywell Electronic Gas Valve WARNING FIREPLACES EQUIPPED WITH OPTIONAL ACCESSORY DOORS SHOULDBEOPERATEDONL...

Страница 5: ...ance and call a qualified service technician The control lever snaps into place at either extreme of its range of motion When locked in position all the way to the right the damper is open When locke...

Страница 6: ...LECTRICAL POWER BEFORE SERVICING THE APPLIANCE Millivolt Appliance Checkout The pilot flame should be steady not lifting or floating Flame should be blue in color with traces of orange at the outer ed...

Страница 7: ...on Procedure Inspecting Cleaning Burner Logs and Controls Check Flame Patterns and Flame Height Inspecting Cleaning Pilot and Burner Checking Vent System Appliance Checkout Replacing Rockwool Ember Ma...

Страница 8: ...re 12 Spread along the front edge of the front burner Do not use more than is necessary When properly positioned the rockwool will unevenly cover approximately 85 of the gap between the front burner a...

Страница 9: ...tch Attachment Only Limit Switch BK WHT BK BK BK SIT Millivolt Wiring Diagram For Wall Switch Attachment Only If any of the original wire as supplied must be replaced it must be replaced with Type AWM...

Страница 10: ...s go to the next step 7 Push in gas control knob slightly and turn counterclockwise to PILOT 8 Push in control knob all the way and hold in Immediately light the pilot by triggering the spark ignitor...

Страница 11: ...Ne touchez aucun commutateur lectrique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter...

Страница 12: ...use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has...

Страница 13: ...aire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural la...

Страница 14: ...essure It should be within the limits as marked on the rating plate Clean or replace pilot orifice Check pilot flame it must impinge on thermogenerator Figure 9 Clean and or adjust pilot for maximum f...

Страница 15: ...surements Must Be Taken While The Igniter Is Powered When Measured Voltage At Connections Use Care To Assure Terminals Are Not Damaged Replace Valve Replace Valve 24 Volt Hot End View Of Control Harne...

Страница 16: ...he description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or ap plication of this syst...

Страница 17: ...RCL is designed to operate with all millivolt ignition systems as well as electronic ignition systems It may be installed with use for either natural or propane gas appliances The RCL offers ease of...

Страница 18: ...4001 1 74L8801 1 11 Bag of Rockwool 88L53 1 88L53 1 12 Limit Switch 62L1601 1 62L1601 1 13 Damper Switch 82L5901 1 82L5901 1 GAS CONTROLS ELECTRONIC Natural Propane No DESCRIPTION Part No Qty Part No...

Страница 19: ...19 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 24 22 20 3 4 5 6 7 2 1 31 30 10 REF 10 21 25 26 23 33 9 8 11 32 c b a d e 13 12 27...

Страница 20: ...25 007M REV G 07 2004 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consul...

Отзывы: