NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

WARNING:  DAMPER MUST BE IN OPEN
POSITION WHEN APPLIANCE MAIN
BURNER IS OPERATING.

AVERTISSEMENT:  LE REGISTRE DOIT
ÊTRE EN POSITION OUVERTE LORSQUE
LE OU LES BRULEURS PRINCIPAUX DE
L'APPEREIL FONCTIONNMENT.

Figure 5

Figure 6

WARNING:  DO NOT OPERATE THE COM-
BUSTION AIR ACTUATOR UNLESS A
COMPLETE OUTSIDE AIR VENT SYS-
TEM HAS BEEN INSTALLED WITH YOUR
APPLIANCE.

Pull the actuator forward to open the combus-
tion air door, and push it back to close.  To "lock"
the combustion air door closed, ensure the
actuator is pushed all the way back, then  push
the end of the actuators to the right until the
step in the actuator moves behind the appliance
front face within the slotted opening.

MANUALLY-RESET BLOCKED FLUE SAFETY
SWITCH

This appliance is equipped with a manually-
reset blocked flue safety switch.  Refer to

Figure 7

  for its location.  If during appliance

operation, the flame goes out (independently
of the burner on/off wall switch), it may be due
to the  operation of this safety limit switch.
First 

allow the appliance to coo

l, then reset

the safety switch by pushing the red reset
button on the back of the switch.

CAUTION: THE ELECTRONIC APPLIANCE
SHOULD BE TURNED OFF BEFORE REMOV-
ING THE LIMIT SWITCH.

To access the safety limit switch reset button,
remove the screen rod and screen from the
right side of the fireplace.  Unscrew two screws
and remove the limit switch with low voltage
wires attached.  Push the reset button, then
reinstall the limit switch.  Reinstall the screen
and rod.  At this time turn the electronic
appliance back on.

The appliance should then relight and remain
lit.  If this does not occur, 

turn off the appli-

ance and call a qualified service technician

.

The control lever snaps into place at either
extreme of its range of motion.  When locked
in position all the way to the  right, the damper
is open.  When locked in position all the way to
the left, the damper is closed.

The damper lever actuates a switch, (see wir-
ing diagram) which will prevent the appliance
main burner from lighting unless the damper
is locked open.  The appliance flue damper
must always remain open when operating.

Remove Locking Screw
and “Pop” Actuator to the
Left Before Initial Use

Combustion Air
Actuator

Pull Forward to Open,
Push Back to Close

Many appliances are equipped when installed
with an outside (make-up) air vent system that
is designed to provide the appliance with out-
side make-up air for combustion when in
operation.  The actuator for the outside air
system is standard on all appliances but must
not be operated if the complete system is not
installed.  Refer to 

Figure 6.

  When the com-

plete outside air vent system is installed, the
installer will remove the actuator locking screw.

If your screw is not removed and you have
reason to believe that you have a complete
outside air system, contact your distributor to
have your appliance inspected for the pres-
ence of the complete system.

DO NOT assume that you have this system in
place because you have an actuating lever
present on your appliance front face.

Figure 7

Damper
Closed

Damper

Open

Lintel

Outside Air

Actuator

Limit Switch Screws

Manual

Reset

Limit

Switch

Screen
Rod

Lintel Extension

Right Side Refractory Panel

Screen

To provide outside combustion air to your
appliance while it is in operation, locate the
combustion air actuator along the right side of
the appliance opening 

(

Figure 5 ).

To operate, push the end of the actuator to the
left as shown in 

Figure 6

, until it "pops" free of

its "locked" position.

Содержание STANDARD SERIES and

Страница 1: ...LO SION MAY RESULT CAUSING PROPERTY DAM AGE PERSONAL INJURY OR LOSS OF LIFE POURVOTRES CURIT Nepasentreposerniutiliser d essencenid autrevapeursouliquidesinflammables dans le voisinage de cet appareil...

Страница 2: ...vides safe efficient operation External electri cal power is required to operate these units GENERAL INFORMATION Note Installation and repair should be per formedbyaqualifiedserviceperson Theappli an...

Страница 3: ...SURED ENVIRONMENTS PRESSUREWITHINTHEHOMEISLESS THAN PRESSURES OUTSIDE SIGNIFI CANT NEGATIVELY PRESSURED ENVI RONMENTS CAUSED BY WEATHER HOME DESIGN OR OTHER DEVICES MAYIMPACTTHEOPERATIONOFTHESE APPLIA...

Страница 4: ...pliance area clear and free from combustible materials gasoline and other flammable liquids Honeywell Electronic Gas Valve WARNING FIREPLACES EQUIPPED WITH OPTIONAL ACCESSORY DOORS SHOULDBEOPERATEDONL...

Страница 5: ...ance and call a qualified service technician The control lever snaps into place at either extreme of its range of motion When locked in position all the way to the right the damper is open When locke...

Страница 6: ...LECTRICAL POWER BEFORE SERVICING THE APPLIANCE Millivolt Appliance Checkout The pilot flame should be steady not lifting or floating Flame should be blue in color with traces of orange at the outer ed...

Страница 7: ...on Procedure Inspecting Cleaning Burner Logs and Controls Check Flame Patterns and Flame Height Inspecting Cleaning Pilot and Burner Checking Vent System Appliance Checkout Replacing Rockwool Ember Ma...

Страница 8: ...re 12 Spread along the front edge of the front burner Do not use more than is necessary When properly positioned the rockwool will unevenly cover approximately 85 of the gap between the front burner a...

Страница 9: ...tch Attachment Only Limit Switch BK WHT BK BK BK SIT Millivolt Wiring Diagram For Wall Switch Attachment Only If any of the original wire as supplied must be replaced it must be replaced with Type AWM...

Страница 10: ...s go to the next step 7 Push in gas control knob slightly and turn counterclockwise to PILOT 8 Push in control knob all the way and hold in Immediately light the pilot by triggering the spark ignitor...

Страница 11: ...Ne touchez aucun commutateur lectrique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter...

Страница 12: ...use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has...

Страница 13: ...aire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural la...

Страница 14: ...essure It should be within the limits as marked on the rating plate Clean or replace pilot orifice Check pilot flame it must impinge on thermogenerator Figure 9 Clean and or adjust pilot for maximum f...

Страница 15: ...surements Must Be Taken While The Igniter Is Powered When Measured Voltage At Connections Use Care To Assure Terminals Are Not Damaged Replace Valve Replace Valve 24 Volt Hot End View Of Control Harne...

Страница 16: ...he description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or ap plication of this syst...

Страница 17: ...RCL is designed to operate with all millivolt ignition systems as well as electronic ignition systems It may be installed with use for either natural or propane gas appliances The RCL offers ease of...

Страница 18: ...4001 1 74L8801 1 11 Bag of Rockwool 88L53 1 88L53 1 12 Limit Switch 62L1601 1 62L1601 1 13 Damper Switch 82L5901 1 82L5901 1 GAS CONTROLS ELECTRONIC Natural Propane No DESCRIPTION Part No Qty Part No...

Страница 19: ...19 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 24 22 20 3 4 5 6 7 2 1 31 30 10 REF 10 21 25 26 23 33 9 8 11 32 c b a d e 13 12 27...

Страница 20: ...25 007M REV G 07 2004 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consul...

Отзывы: