4

Gas Pressure - All Models

Tables 3 and 4  show the appliances' gas 

pressure requirements:

Inlet Gas Supply Pressure

(all models)

Fuel #

Minimum

Maximum

Natural Gas

5.0" WC

(1.24 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.23 kPa)

Table 3

Manifold Gas Supply Pressure

(all models)

Fuel #

Low

(millivolt only)

High

Natural 

Gas

(Lo) 2.2" WC

(.55 kPa)

(Hi) 3.5" WC

(.87 kPa)

Propane (Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 4

Test  gauge  connections  are  provided  on  the 

front of the millivolt gas control valve, identi-

fied IN for the inlet and OUT for the manifold 

side.    A  1/8"  NPT  Test  gauge  connection 

is  provided  at  the  inlet  and  outlet  side  of   

the electronic gas control valve.

Gas Valve Diagrams - 

See Figure 1  for Millivolt 

models and Figure 2 For Electronic Models.

HI

LO W

HT

PT

HT

PT

PILO

T

PIL

OT

ON

it

OFF

IN

OUT

Manifold Pressure Tap

Inlet Pressure Tap

Pilot Adjustment

Screw

HI/LO Variable 

Flame Height 

Adjustment

Main Gas Control Knob

OFF/PILOT/ON

Figure 1 - 

SIT Millivolt  Gas Valve

Figure 2 - 

Honeywell Electronic  Gas Valve

FF

O

NI

P

S

I

N

O

L

O

RT

N

O

C

GI

N

TIER

Manifold Pressure 

Port

ON / OFF Switch

Inlet 

Pressure

Port

Electronic Gas 

Control Valve

These appliances must be isolated from the 

gas supply piping system (by closing their 

individual manual shut-off valve) during any 

pressure  testing  of  the  gas  supply  piping 

system  at  test  pressures  equal  to  or 

less 

than

 1/2 psig (3.5 kPa).

These appliances and their individual shut-off 

valves must be disconnected from the gas 

supply piping system during any pressure 

testing of that system at pressures 

greater 

than

 1/2 psig (3.5 kPa).

These appliances must not be connected to a 

chimney or flue serving a separate solid fuel 

burning appliance.

Orifice Sizes -  Sea Level to High Altitude

(All Models)

These appliances are tested and approved for 

installation at elevations of 0-4500 feet (0-1372 

meters)  above  sea  level  using  the  standard 

burner orifice sizes (marked with an "*" in Table 

5).  For elevations above 4500 feet, contact your 

gas supplier or qualified service technician. 

Deration  -

  At  higher  elevations,  the  amount 

of BTU fuel value delivered must be reduced 

by either:

•   Using gas that has been derated by the gas 

company. 

•   Changing the burner orifice to a smaller size 

as regulated by the local authorities having 

jurisdiction and by the (USA) National Fuel 

Gas  Code  NFPA  54/ANSI  Z223.1  -  latest 

edition or, in Canada, the CAN/CSA-B149.1 

codes - latest edition.

Install the appliance according to the regulations 

of the local authorities having jurisdiction and, 

in the USA, the National Fuel Gas Code NFPA 

54 / ANSI Z223.1 - latest edition or, in Canada, 

the CAN/CSA-B149.1 - latest edition.

NOTE: Flame appearance will diminish 4% per 

thousand feet.

NOTE:  Each  model  has  two  burners  and  2 

Orifices.

REQUIREMENTS  FOR  THE  COMMON-

WEALTH OF MASSACHUSETTS

These fireplaces are approved for installation in 

the US state of Massachusetts if the following 

additional requirements are met:

•  Install  this  appliance  in  accordance  with 

Massachusetts Rules and Regulations 248 

C.M.R. 

•  Installation and repair must be done by a 

plumber or gas fitter licensed in the Com-

monwealth of Massachusetts.

•  The flexible gas line connector used shall 

not  exceed  36  inches  (92  centimeters)  in 

length.

•  The individual manual shut-off must be a 

T-handle type valve.

Massachusetts Horizontal Vent Requirements 

In the Commonwealth of Massachusetts, hori-

zontal terminations installed less than seven 

(7) feet above the finished grade must comply 

with the following additional requirements:

•  A  hard  wired  carbon  monoxide  detector 

with an alarm and battery back-up must be 

installed  on  the  floor  level  where  the  gas 

fireplace is installed.  The carbon monoxide 

detector must comply with NFPA 720, be 

ANSI/UL 2034 listed and be ISA certified.

•  A metal or plastic identification plate must 

be permanently mounted to the exterior of 

the building at a minimum height of eight (8) 

feet above grade and be directly in line with 

the horizontal termination.  The sign must 

read, in print size no less than one-half (1/2) 

inch in size, GAS VENT DIRECTLY BELOW.  

KEEP CLEAR OF ALL OBSTRUCTIONS.

NEW YORK CITY, NEW YORK (MEA)

Installation  of  these  fireplaces  are  approved 

for installation in New York City in the US state 

of New York.

Burner Orifice Sizes 

Elevation 0-4500 feet ( 0-1372 meters)

Model

Series

Nat.Gas

drill size (inches)

Propane

drill size (inches)

SSDVST

SSDVPF

#44 (.086") 

*

60J80 •

#55 (.052")

**

19L52 •

Table 5

* Standard size installed at factory

** Standard size in LP conversion kit

•  Part /Cat. Number

Содержание SSDVPF-CNE-B

Страница 1: ...de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur s par...

Страница 2: ...e installed the electrical power must be provided at the time of appliance in stallation The Electronic appliances have an electronic intermittent pilot ignition system External electrical power is re...

Страница 3: ...y be required due to excessive lint from carpeting bed ding material etcetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Remarque...

Страница 4: ...e reduced by either Using gas that has been derated by the gas company Changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the USA National F...

Страница 5: ...rer s instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the United States or the StandardforInstallationinMobileHomes CAN CSA Z240 MH Series in Canada C...

Страница 6: ...54 ANSI Z223 1 Roof Pitch Feet Meters Flat to 6 12 1 0 0 3 6 12 to 7 12 1 25 0 38 7 12 to 8 12 1 5 0 46 8 12 to 9 12 2 0 0 61 9 12 to 10 12 2 5 0 76 10 12 to 11 12 3 25 0 99 11 12 to 12 12 4 0 1 22 12...

Страница 7: ...cm for appliances 10 000 BTU hr 3kW 12 in 30 cm for appliances 10 000 BTU hr 3kW and 100 000 BTU hr 30kW 36 inches 91 cm for appliances 100 000 BTU hr 30kW 6 in 15 2 cm for appliances 10 000 BTU hr 3...

Страница 8: ...owing exception If the optional radiant panels are installed the non combustible material may cover any portion of the top radiant panel or the air gaps surrounding the top radiant panel down to the t...

Страница 9: ...plates and remove the cardboard from beneath each plate be careful not to damage the white gasket See Figure 10 NOTE INSTALLATION DIAGRAMS AND INSTRUCTIONSSHOWTHEFRONTOFTHE APPLIANCEASTHESIDEWHICHHAS...

Страница 10: ...108 679 11 3 8 267 289 7 178 5 1 8 130 12 1 8 308 10 1 2 22 3 4 578 6 1 4 159 A 7 178 5 1 8 130 12 1 8 308 26 3 4 Provide additional space for Side Vent Seal Cap if installing against a solid wall Lou...

Страница 11: ...uance without notice Appliance has a factory installed vent seal cap see Figures 15 and 16 on Page 13 in each flue outlet EFFICIENCIES SSDVPF 58 NG 61 LP Steady State 72 NG 73 LP AFUE 68 NG 68 LP Louv...

Страница 12: ...torand1 2inchshutoff valve see Figure 47 on Page 27 See Massachusetts Requirements on Page 4 foradditionalrequirementsfor installations in the state of Massachusetts in the USA The gas supply line sho...

Страница 13: ...1 in Canada Ensure clearances are in accordance with local installation codes and the requirements of the gas supplier D gagementconformeauxcodesd installationlocauxetauxexigences du foumisseunde gaz...

Страница 14: ...0 0 3 5 4 5 7 3 0 0 2 0 0 2 5 6 4 5 7 8 3 0 0 0 0 1 1 5 9 4 5 2 1 4 1 0 2 0 0 3 1 5 5 2 4 1 0 0 0 1 2 5 5 5 5 2 6 4 0 1 2 0 0 3 7 5 5 7 4 0 0 1 1 0 2 6 6 5 2 5 0 2 2 0 0 4 5 7 6 5 2 6 5 0 0 3 0 0 3 9...

Страница 15: ...4 5LA may be used to provide the installer with an option in installing in tight and confined spaces or where the vent run made up of fixed length pieces develops a joint in a undesirable location or...

Страница 16: ...ections see Figure 23 Use a carpenter s level to measure from a constant surface and adjust the support straps as necessary It is important to maintain the required clear ancestocombustibles 1 25mm at...

Страница 17: ...ori zontal vent run is needed then 4 feet minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio Forevery1footof V verti cal you are allowed 5 feet of H horizontal run up to a...

Страница 18: ...4 2 0 610 1 0 305 10 3 048 4 1 219 2 0 610 15 4 572 6 1 829 3 0 914 20 6 096 8 2 438 4 1 219 V V1 H H1 40feet 12 2m Max H 8 feet 2 438 meters Max H H1 20 feet 6 096 meters Max Example If 20 feet total...

Страница 19: ...geandsealboththe inner and outer pipe elements with the same procedure Sealant and securing screws are not required Note An elbow may also be attached to the appliance collar Attach in the same manner...

Страница 20: ...ey are in the same area as a hot termination To prevent contact with hot surfaces we recommend the use of a Termination Guard See Page 33 This can be purchased at your local dealer SV4 5HT 2 Terminati...

Страница 21: ...hes mm Termination Kit Only 6 to 9 1 4 152 to 235 TerminationKitand 6In Vent Section SV4 5L6 10 3 4 to 14 273 to 356 Termination Kit and 12 in Vent Section SV4 5L12 16 3 4 to 20 426 to 508 Termination...

Страница 22: ...5HF uWhen using Secure Flex use Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4 5HF Note See Table 9 as an aid in venting component selection for a particular range of exterior...

Страница 23: ...meters Max H H1 H2 20 feet 6 096 meters Max Example If 20 feet total H H1 H2 horizontal vent run is needed then 4 feet minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio F...

Страница 24: ...nner flexible vent pipe push it back out of the way 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adapter collar approximately 1 2 inch from the end 3 Pull a...

Страница 25: ...es 43 and 44 b Optional Wall Switch Wall Thermostat OrRemoteControlReceiver Installsnap bushing provided in Electrical Outlet Kit See Figure 44 into control switch knock out in side panel see Figures...

Страница 26: ...x Wiring when using unit mounted relay module BK W G C A V 0 2 1 Igniter Connector Leave the OFF ON switch which is integral with the gas valve in the ON position Optional Control Switches Wall Switch...

Страница 27: ...that will allow the shut off valve to be easily attached by hand to the gas flex line Using pipe dressing materials appropriate for the gas type securely affix the shut off valve to this determined pi...

Страница 28: ...al tongues of flame on the burner Make sure all ports are open and producing flame evenly across the burner If any ports are blocked or partially blocked clean out the ports With the gas line installe...

Страница 29: ...ers as it is being installed c Asafinalcheckforcorrectlogsetplacement check that the four outer notches on the underside of the log set fit over the burner tines as indicated in Figure 53 Burner Grate...

Страница 30: ...ld be increased If air shutter is open too far Flame will be blue Air shutter gap should be decreased Step 9 INSTALLATION AND REMOVAL OF GLASS DOOR Only doors certified with the appliance shall be use...

Страница 31: ...lly clockwise Propane fully counter clockwise Settings are shown for each burner Air Shutter Adjusting Rod Air Shutter Adjusting Arms Orifice Increase Shutter Opening In This Direction Decrease Shutte...

Страница 32: ...ur liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque de l interrupteur mural qui contr le le foyer Figure A ou du thermostat mural Figure B Choisis...

Страница 33: ...flashings come packaged with a storm collar 6 77L78 SV4 5F Flat Roof Flashing 6 77L79 SV4 5FA 1 2 to 7 12 Adjustable Flashing 6 77L80 SV4 5FB 7 2 to 12 12 Adjustable Flashing 7 77L81 SV4 5SC6 Storm Co...

Страница 34: ...12 Mill Pac Black High Temperature Sealant Bulk 12 pack 23 91L66 SF GC4 6 Gear Clamp 4 5 in 114 mm for flex 6 pieces 23 91L67 SF GC7 6 Gear Clamp 7 5 in 190 5 mm for flex 6 pieces 25 H1988 CTSA 33 Ch...

Страница 35: ...th the re quirements of the CAN CSA B149 1 Installation code Laconversiondevra treeffectu e conform ment aux recommanda tions des autorit s provinciales ayant juridiction et conform ment aux exigences...

Страница 36: ...rimary air opening setting NOTE Each model has two burners and 2 Orifices Pilot Orifice Pilot Assembly Igniter Assembly Retaining Clip Flare Nut Note If the igniter is damaged a replacement kit is ava...

Страница 37: ...S NOTE INSTALL REAR BURNER FIRST THEN FRONT BURNER BURNER ORIFICE Step 10 Reassemble the remaining compo nents by reversing the procedures outlined in the preceding steps Step 11 Attach the conversion...

Страница 38: ...38 NOTES...

Страница 39: ...39 39 NOTES...

Страница 40: ...earth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor...

Отзывы: