background image

3

SUPERIOR DIRECT-VENT GAS FIREPLACES  •  MODELS SLDVT-30/35/40/45  •  INSTALLATION INSTRUCTIONS

       WARNING 

Improper  installation,  adjust-

ment,  alteration,  service  or 

maintenance  can  cause  injury 

or  property  damage.    Refer  to 

this manual.  For assistance or 

additional  information  consult 

a  qualified  installer,  service 

agency or the gas supplier.

       WARNING 

Failure  to  comply  with  these 

installation instructions will result 

in  an  improperly  installed  and 

operating appliance, voiding its 

warranty.  Any change to this appli-

ance and/or its operating controls 

is dangerous.

       WARNING 

Clothing  or  other  flammable 

material  should  not  be  placed 

on or near the appliance.

       AVERTISSEMENT 

On  ne  devrait  pas  placer  de 

vêtements  ni  d’autres  matières 

inflammables sur l’appareil ni à 

proximité.

       WARNING 

Any  safety  screen  or  guard 

removed for servicing the appli-

ance must be replaced prior to 

operating the appliance.

       AVERTISSEMENT 

Tout écran ou protecteur retiré 

pour  permettre  l’entretien  de 

l’appareil  doit  être  remis  en 

place avant de mettre l’appareil 

en marche.

Note: Installation and repair should be done 

by a qualified service person. The appliance 

should be inspected before use and at least 

annually by a professional service person. 

More  frequent  cleaning  may  be  required 

due  to  excessive  lint  from  carpeting,  bed-

ding  material,  etcetera.  It  is  imperative 

that  control  compartments,  burners  and 

circulating air passageways of the appliance 

be kept clean.
Remarque  :  L’installation  et  la  réparation 

devrait être confiées à un technicien qualifié. 

L’appareil devrait faire l’objet d’une inspec-

tion  par  un  technicien  professionnel  avant 

d’être utilisé et au moins une fois l’an par la 

suite. Des nettoyages plus fréquents peuvent 

être  nécessaires  si  les  tapis,  la  literie,  et 

cetera produisent une quantité importante de 

pous-sière. Il est essentiel que les comparti-

ments abritant les commandes, les brûleurs et 

les conduits de circulation d’air de l’appareil 

soient tenus propres.

Do  not  use  these  appliances  if  any  part 

has been under water.  Immediately call a 

qualified, professional service technician 

to inspect the appliance and to replace any 

parts  of  the  control  system  and  any  gas 

control which have been under water.
Ne pas utiliser cet appareil s’il a été plongé, 

même  partiellement,  dans  l’eau.  Ap-

peler un technicien qualifié pour inspecter 

l’appareil  et  remplacer  toute  partie  du 

système de commande et toute commande 

qui a été plongée dans l’eau.

IMPROPER INSTALLATION OR USE OF THIS 

APPLIANCE CAN CAUSE SERIOUS INjURY OR 

DEATH FROM FIRE, BURNS, EXPLOSION OR 

CARBON MONOXIDE POISONING.

Only trim kit(s) supplied by the manufacturer 

shall be used in the installation of this ap-

pliance.
Seules  les  trousses  de  garniture  fournies 

par le fabricant doivent être utilisées pour 

l’installation de cet appareil.

These  appliances  comply  with  National  Safety 

Standards  and  are  tested  and  listed  by  ETL/

Intertek  (Report  No.  100353019PRT-001)  to 

ANSI Z21.88 (in Canada, CSA-2.33), and CAN/

CGA-2.17-M91  in  both  USA  and  Canada,  as 

vented gas fireplace heaters.

Both  millivolt  and  electronic  versions  of 

these  appliances are listed by ETL/Intertek 

for installation in bedrooms and Manufac-

tured Homes. 

Misc. Codes / Standards -

The Installation must conform to local codes or, 

in the absence of local codes, with the National 

Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest 

edition (In Canada, the current CAN/CSA-B149.1 

installation code).

The appliance, when installed, must be electri-

cally grounded and wired in accordance with 

local codes or, in the absence of local codes, 

with the National Electrical Code, ANSI/NFPA 

70 - latest edition, or the Canadian Electrical 

Code, CSA C22.1 - latest edition.

Provide adequate clearances around air open-

ings and adequate accessibility clearance for 

service and proper operation. Never obstruct the 

front or  back openings of the appliance.

These appliances are designed to operate on 

natural or propane gas only. The use of other 

fuels  or  combination  of  fuels  will  degrade 

the performance of this system and may be 

dangerous.

These fireplaces are designed as supplemental 

heaters.  Therefore,  it  is  advisable  to  have  an 

alternate  primary  heat  source  when  installed 

in a dwelling.

Millivolt Models - 

The millivolt appliances are 

manually controlled and feature a spark igniter 

(piezo) that allows the appliance's pilot gas to 

be lit without the use of matches or batteries.  

This system provides continued service in the 

event of a power outage.

Millivolt models come standard with a manu-

ally-modulated gas valve; flame appearance and 

heat output can be controlled at the gas valve. 

The BTU Input for these appliances is shown 

in Table 1.

Electronic  Models  - 

These  electronic  appli-

ances are manually controlled and feature an 

electronic  intermittent  pilot  ignition  system.  

External electrical power is required to operate 

these units.

These electronic models come standard with a 

manually-modulated gas valve; flame appear-

ance and heat output can be controlled at the 

gas valve. The BTU Input for these appliances 

is shown in

 

Table 1

.

 Input (BTU/HR) Manually-Modulated 

Gas Valves (all models)

Models

Input Rate (BTU / HR)

Nat. Gas

Prop. Gas

SLDVT-30

  

13,500 high

10,000 low

11,500 high

9,000 low

SLDVT-35

 

16,000 high

12,750 low

15,000 high

11,400 low

SLDVT-40

20,000 high

15,500 low

18,000 high

14,000 low

SLDVT-45

23,000 high

17,500 low

22,000 high

17,000 low

Table 1

Содержание SLDVT Series

Страница 1: ...death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR L...

Страница 2: ...system Noexternalelectricalpowerisrequired to operate these appliances These vented gas fireplace heaters are sealed combustion air circulating gas fireplaces de signed for residential applications Ap...

Страница 3: ...supplied by the manufacturer shall be used in the installation of this ap pliance Seules les trousses de garniture fournies par le fabricant doivent tre utilis es pour l installation de cet appareil T...

Страница 4: ...USA the National Fuel Gas Code NFPA 54 ANSI Z223 1 latest edition or in Canada the CAN CSA B149 1 latest edition REQUIREMENTS FOR THE COMMON WEALTH OF MASSACHUSETTS Thesefireplacesareapprovedforinstal...

Страница 5: ...entirebottomsurface must be used Cold Climate Insulation For cold climate installations seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room It...

Страница 6: ...6 12 1 0 0 3 6 12 to 7 12 1 25 0 38 7 12 to 8 12 1 5 0 46 8 12 to 9 12 2 0 0 61 9 12 to 10 12 2 5 0 76 10 12 to 11 12 3 25 0 99 11 12 to 12 12 4 0 1 22 12 12 to 14 12 5 0 1 52 14 12 to 16 12 6 0 1 83...

Страница 7: ...r e t e m t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e...

Страница 8: ...houldberoutedinawaytominimizeobstructions to the space above the appliance Do not insulate the space between the appliance and the area above it see Figure 8 The minimum height from the base of the ap...

Страница 9: ...nttothenailingflanges areEXEMPTfromthe 1 2 clearance to combustible requirements for the firebox outer wrapper Combustible framing may be in direct contact with the nailing flanges and may be located...

Страница 10: ...ming Dimensions Model A B C D SLDVT 30 in 30 1 4 35 1 4 39 1 4 16 mm 768 895 997 406 SLDVT 35 in 35 1 4 35 1 4 39 1 4 16 mm 895 895 997 406 SLDVT 40 in 40 1 4 40 1 4 44 1 4 16 mm 1022 1022 1124 406 SL...

Страница 11: ...anty Proper Sizing of Gas Line Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel G...

Страница 12: ...xigences du foumisseunde gaz Useonlyapprovedventingcomponents See Approved Vent Components on Page 2 These fireplaces must be vented directly to the outside The vent system may not service multiple ap...

Страница 13: ...1 1 4 0 5 2 4 1 0 0 1 0 1 2 1 5 1 1 5 5 2 6 2 4 0 0 0 0 1 1 1 1 5 0 2 5 5 7 3 3 4 0 2 0 1 1 1 4 1 1 3 5 5 2 4 4 0 2 2 0 1 1 5 1 5 8 3 5 5 7 8 4 4 1 0 0 2 1 1 4 1 9 4 5 5 7 5 4 1 0 2 1 1 1 5 1 8 5 5 5...

Страница 14: ...ations Where required a telescopic vent section SV4 5LA may be used to provide the installer withanoptionininstallingintightand confined spaces or where the vent run made up of fixed length pieces dev...

Страница 15: ...ion to align with the required direction of the next vent run element Twist elbow sections in a clockwise direction onlysoastoavoidthepossibilityofunlocking any of the previously connected vent sectio...

Страница 16: ...smaller are accept able all the way down to at or near level SV4 5VF Secure Vent SF4 5VF Secure Flex firestop spacer must be used anytime vent pipe passes through a combustible floor or ceiling SV4 5H...

Страница 17: ...Max Figure 27 Top Vent three elbows SUPERIOR DIRECT VENT GAS FIREPLACES MODELS SLDVT 30 35 40 45 INSTALLATION INSTRUCTIONS VERTICAL VENT FIGURES TABLES continued Horizontal Outside Wall Termination S...

Страница 18: ...possibility of unlocking any ofthepreviouslyconnectedventsections see Figure 19 on Page 14 I Continue installation of horizontal inclined sections Continue with the installation of the straight vent...

Страница 19: ...on is hot while in operation and for a period of time following the use of the fireplace To prevent contact with hot surfaces we recommend the use of a Termina tion Guard See Page 37 This can be purch...

Страница 20: ...VERTICAL COMPONENT IN THE SYSTEM See Figure 31 Use Table 8 as an aid in venting component selection for a particular range of exterior wall thicknesses Figure 32 Top Vent ONE 90 DEGREE ELBOW ELBOW CON...

Страница 21: ...ELBOWS SUPERIOR DIRECT VENT GAS FIREPLACES MODELS SLDVT 30 35 40 45 INSTALLATION INSTRUCTIONS See Table 8 on Page 20 as an aid in venting component selection for a particular range of exterior wall th...

Страница 22: ...V4 5HF Ceiling Firestop Spacer SV4 5VF When using Secure FlexTM use Firestop Spacer SF4 5VF When using Secure Flex use Firestop Spacer SF4 5HF Wall Firestop Spacer SV4 5HF See Table 8 on Page 20 as an...

Страница 23: ...inner flexible vent pipe 4 Slidetheinnerflexpipeovertheadaptorcol lar Ensure the flexible vent pipe completely engages the adaptor collar to a distance of 1 3 4 inches from the end and that it is fre...

Страница 24: ...N ORANGE THTP BLACK TP GREEN TH TO WALL SWITCH OR THERMOSTAT Refer to Section A for millivolt appliances and Section B for electronic appliances The gas valve is set in place and pre wired at the fact...

Страница 25: ...0 After the wiring is complete replace the cover plate Note No batteries to be installed in the battery holder until a power outage or if the appli ance is to be operated solely with two 2 D batteries...

Страница 26: ...s Proceed as follows Acquire the shut off valve and gas lex line and pull the assembly forward out of the compart ment Separate the shut off valve from the gas flex line Determine the length of pipe n...

Страница 27: ...at the right and left sides of the burner Positionanyceramicfiberlinersbefore placing the stone Logs can be positioned after the volcanic stone SUPERIOR DIRECT VENT GAS FIREPLACES MODELS SLDVT 30 35...

Страница 28: ...ing instructions 1 Place the left front log 1 as shown Posi tion it on the two left front log brackets 2 Placetherightfrontlog 2 asshown Posi tion it on the two right front log brackets 3 Place the le...

Страница 29: ...ign the hole at the bottom of log 4 over the Nub of log 2 as shown 4 2 1 Right Rear Bracket Rockwool Do Not Place Rockwool Over Burner Slots 1 Right Front Brackets Left Front Brackets 3 1 Right Front...

Страница 30: ...n the hole at the bottom of log 5 over the Nub of log 3 as shown 3 5 Left Rear Bracket Right Rear Bracket Right Front Brackets Left Front Brackets Place Ember Chunk Here Align hole at the bottom of le...

Страница 31: ...om of left front log 1 over the left front brackets and the right front log 2 over the right front brackets 5 2 1 3 4 5 Left Rear Brackets Right Rear Bracket Right Front Brackets Left Front Brackets C...

Страница 32: ...two latches located underneath the firebox floor to the door s vee flange Close both the latches securely 8 Installthehood Notethelocationofthethree clipsinsidethetopairchannelabovethedoor Theclipsare...

Страница 33: ...st air shutter to the standard set ting as shown in Figure 54 adjustment rod is located in the lower control compartment Note Move the adjustment rod down to decrease air and up to increase 2 Light ap...

Страница 34: ...g flush with the finished wall position framework to accommodate the thickness of the finished wall Figure 55 See Page 5 for Cold Climate Insulation and Page 8 for Clearances Top Of Appliance 3 76 mm...

Страница 35: ...s proporcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor o el termostato de pared quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encend...

Страница 36: ...id 3 1 1 spacing 10 Pack H2247 SV4 5VF 10 Firestop Spacer Vertical rigid 1 1 1 spacing 10 Pack 96K92 SV4 5SP Support Plate SUPERIOR DIRECT VENT GAS FIREPLACES MODELS SLDVT 30 35 40 45 INSTALLATION INS...

Страница 37: ...SFGC7 6 Gear Clamp 7 5 in 190 5 mm for flex 6 pack H7748 H7748 36 Flex Connector Kit 36 offlexwithtwoadapters formatingtworigidsections of vent together Listed Secure Vent Components Cat Model Descri...

Страница 38: ...LEC TRIQUE Step 2 Remove the front glass door frame Step 3 Carefully remove the logs Exercise care so as not to break the logs Step 4 Refer to Figure 56 Remove the burner assembly with attached ventu...

Страница 39: ...ot hoodassemblytoaccessthehexedpilotorifice Remove and replace the orifice with the one provided with the kit Figure 57 Figure 58 Pressure Regulator Remove These Components Pilot Orifice Figure 59 Dex...

Страница 40: ...e changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1508 Elm...

Отзывы: