Efficiencies (%)
Model
Natural Gas
Propane
AFUE
EnerGuide (P4)
AFUE
EnerGuide (P4)
SLDVT-30
57
51
58
54
SLDVT-35
59
59
61
61
SLDVT-40
62
61
64
61
SLDVT-45
64
59
66
61
10
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
FIREPLACE AND FRAMING SPECIFICATIONS
Vent Size
Coaxial DV
Vent Size
4-1/2" Inner
7-1/2" Outer
Vertical Venting Through the Ceiling:
Frame ceiling opening
-
Use a plumb line from the ceiling above the appliance to
locate center of the vertical run. Cut and/or frame an opening, 10-1/2" x 10-1/2" (267
mm x 267 mm) inside dimensions, about this center mark (see Figure 18).
Notes
Diagrams, illustrations and photo-
graphs are not to scale – consult
installation instructions. Product
designs, materials, dimensions,
specifications, colors and prices are
subject to change or discontinuance
without notice.
Input (BTU/HR) - MV & Electronic
Natural & Propane Gas
Models
Input Rate (BTU / HR)
SLDVT-30N
13,500
SLDVT-30P
11,500
SLDVT-35N
16,000
SLDVT-35P
15,000
SLDVT-40N
20,000
SLDVT-40P
18,000
SLDVT-45N
23,000
SLDVT-45P
22,000
Viewable Glass Size
30" Model
24-1/4" Wide
20-1/4" High
35" Model
29-1/4" Wide
20-1/4" High
40" Model
34-1/4" Wide
25-1/4" High
45" Model
39-1/4" Wide
25-1/4" High
Figure 13
Framing
A
B
C
7
(178)
5-1/8
12-1/8
(308)
10-1/2
(
267
)
D
(130)
A
1/2
Framing Dimensions
Model
A
B
C
D
SLDVT-30
in.
30-1/4
35-1/4
39-1/4
16
mm
768
895
997
406
SLDVT-35
in.
35-1/4
35-1/4
39-1/4
16
mm
895
895
997
406
SLDVT-40
in.
40-1/4
40-1/4
44-1/4
16
mm
1022
1022
1124
406
SLDVT-45
in.
45-1/4
40-1/4
44-1/4
16
mm
1149
1022
1124
406
Vent Framing - Top Vent
with One 90° Elbow
Dimension “D” is the required framing depth when the
finish material (drywall) thickness is 1/2 in. (13mm).
Inches (millimeters)
Framing should be
constructed of 2x4 or
larger lumber
.
o
N
l
e
d
o
M
E
F
G
H
J
K
L
M
.
n
i
m
m
SLDVT-35
32-1/4
819
28-1/8
714
23-1/4
590
32
813
35-1/4
895
25
635
12-1/2
317
33
838
.
n
i
m
m
SLDVT-40
37-1/4
946
33-1/8
841
28-1/4
718
37
940
40-1/4
1022
30
762
15
381
38
965
.
n
i
m
m
SLDVT-45
.
n
i
m
m
SLDVT-30
32-1/4
819
37-1/4
946
28-1/8
714
33-1/8
841
23-1/4
590
28-1/4
718
27
686
42
1067
30-1/4
768
45-1/4
1149
20
508
35
889
10
254
17-1/2
445
28
711
43
1092
SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS
J
Front View
H
G
F
E
M
K
L
Top View
*CONCENTRIC FLUE
FLUE - 4-1/2 (114)
COMBUSTION AIR
- 7-1/2 (190)
9-1/4 (235)
1/2
(13)
16 (406)
1-5/8 (42)
NOTE - Eyebrow
hood shown.
GAS INLET
KNOCKOUT
(Other Side)
Right Side View
5-7/8
(149)
NOTE - It is recommended that the gas be stubbed in from the left
side only.
3 (76)
3 (76)
9-1/2
(241)
ELECTRICAL INLET
KNOCKOUT - 2-3/4 X 2
(70 X 51) COVER PLATE
(With KNOCKOUT -
Right Side Only)
OPTIONAL
ELECTRICAL
INLET KNOCKOUT,
REQUIRING A FIELD
PROVIDED
JUNCTION BOX
(Either Side)