background image

18

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

SUPERIOR

®

 DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS

TP-TH

TP

TH

OPTIONAL APPLIANCE-

MOUNTED ON/OFF

SWITCH

BK/W(1)

BK/W(1)

WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)

THERMOSTAT (OPTIONAL)

JUNCTION BOX

BLACK

W

GR

120 

V

AC

WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)

BK

R

WIRING DIAGRAM MILLIVOLT GAS VALVES

THERMOPILE

GAS VALVE

FAN

(OPTIONAL)

Figure 18: Wiring Diagram, 

Millivolt Valve

Figure 19: Wiring Diagram, Electronic Valve

WIRING DIAGRAMS

Wiring diagrams are provided here for reference 

purposes only.  This information is also provided 

on schematics attached directly to the appliance 

on a pullout panel located within the control 

compartment.

CAUTION:  LABEL ALL WIRES 

PRIOR TO DISCONNECTION WHEN 

SERVICING CONTROLS.  WIRING 

ERRORS CAN CAUSE IMPROPER 

AND DANGEROUS APPLIANCE 

OPERATION.

ATTENTION :  AU MOMENT DE 

L'ENTRETIEN DES COMMANDES, 

ÉTIQUETEZ TOUS LES FILS AVANT 

DE LES DÉBRANCHER.  DES 

ERREURS DE CÁBLAGE PEU-VENT 

ENTRAÎNER UN FONCTIONNEMENT 

INADÉQUAT ET DANGEREUX.

ORDERING REPLACEMENT 

PARTS

A complete parts list is found at the end of 

this manual. Use only parts supplied from the 

manufacturer.

With proper care and maintenance, your appli-

ance will provide many years of enjoyment. If 

you should experience any problem, first refer 

to the troubleshooting guide in this manual. 

If the problem persists, contact your Lennox 

Hearth Products dealer or distributor.

Order parts through your Lennox Hearth Prod-

ucts distributor or dealer. Parts will be shipped 

at prevailing prices at time of order.

When ordering parts, provide the following 

information:
1.  Appliance model number
2.  Appliance serial number
       (On appliance label on control compartment floor)
3.  Part number
4.  Part description
5.  Quantity required
6.  Appliance installation date

PRODUCT REFERENCE INFORMATION

Model Number

 ________________________________________________________

Serial Number ________________________________________________________

Date Installed _________________________________________________________

Gas Type Used ________________________________________________________

Dealer Name  _________________________________________________________

Please call Lennox Hearth Products for the 

phone number of your nearest LHP dealer, 

who will answer your questions or address 

your concerns.

LENNOX HEARTH PRODUCTS

1508 Elm Hill Pike, Suite 108 

Nashville, TN 37210

www.LennoxHearthProducts.com

1-800-655-2008

If you encounter any problems or have any 

questions concerning the installation or ap-

plication of this system, please contact your 

dealer or distributor.

PRODUCT REFERENCE  

INFORMATION 

We recommend that you record the important  

reference information about your fireplace in 

the space provided below. 

P/N 580491-01

JUNCTION BOX

120V AC

REMOTE RECEIVER

ON/OFF SWITCH

WALL SWITCH

LIMIT SWITCH

B-VENT MODELS

ONLY

AC/DC 

POWER 

ADAPTOR

HOT

NEUTRAL

OPTIONAL

GROUND

BATTERY HOLDER

DFC WIRE HARNESS

SPARK WIRE CABLE

PILOT GROUND WIRE

PILOT 

SENSOR

CABLE

HOOD

IGNITER ROD

FLAME SENSOR

PILOT TUBE

OPTIONAL CPI SWITCH
OFF (O) = INTERMITTENT PILOT MODE
ON   (-) = STANDING PILOT MODE

PROFLAME DFC BOARD

PROFLAME VALVE

ELECTRONIC PILOT ASSEMBLY

B   = BLACK

BR = BROWN

GY = GRAY

PU = PURPLE

R   = RED

BL  = BLUE

G  = GREEN

O  = ORANGE

W  = WHITE

Y   = YELLOW

WIRING COLOR CODE

B

B

B

R

R

W

W

B

B

B

B

BL

BL

G

G

O

Y

Y

R

R

Y

W

G

G

O

SCHEMATIC REPRESENTATION ONLY

Содержание SLDVT-30NM

Страница 1: ... GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITRÉE CHAUDE PEUT CAUSER DES BRÛLURES LAISSER REFROIDIR LA SURFACE VITRÉE AVANT D Y TOUCHER NE PERMETTEZ JAMAIS À UN ENFANT DE TOUCHER LA SURFACE VITRÉE EL VIDRIO CALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO Do not store or use gaso...

Страница 2: ...ranty Information 6 General Information 7 Operation Care of Your Appliance 8 Gas Controls Access 8 Variable Flame Adjustment 9 Maintenance 10 Front Glass Enclosure Panel Removal and Installation 11 Install Volcanic Stone Embers and Logs 12 Burner Flame Appearance Sooting 15 Burner Flame Adjustments 16 Millivolt Appliance Checkout 16 Electronic Appliance Checkout 16 Ordering Replacement Parts 17 Pr...

Страница 3: ...age 5 Lisez la section Informations importantes relatives à la sécurité page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTRÊMEMENT CHAUDES Instale una malla o barrera física para evitar el contacto directo con el vidrio y prevenir las quemaduras y lesiones graves Ver los detalles a la izquierda para ordenar un Lennox SAFETY GUARD GRATIS para su chimenea Siga las instruc...

Страница 4: ...s enfants ou les adultes peuvent subir des brûlures s ils viennent en contact avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et ...

Страница 5: ...verifiquequeelinterruptor opera la chimenea encendiéndola y apagándola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura B Seleccione el idioma que más se habla en la casa 2 Si se usa un control remoto para controlar la chimenea encuentre el transmisor...

Страница 6: ...y of the warranty accompanying this manual Please read the warranty to be familiar with its coverage Retain this manual File it with your other docu ments for future reference Failure to comply with the installation and operating instructions provided will result in an improperly installed and operating appliance voiding its warranty Do not attempt to alter or modify the construction of the applia...

Страница 7: ...nce will diminish 4 per thousand feet Burner Orifice Sizes Elevation 0 4500 feet 0 1372 meters Model Series Nat Gas drill size inches Propane drill size inches SLDVT 30 50 0 070 in H4873 61 0 039 in 35M91 SLDVT 35 0 0748 in H1355 0 045 in 75L10 SLDVT 40 44 0 086 in 60J80 0 048 in 99K78 SLDVT 45 0 090 in 37L70 54 0 055 in 99K79 Standard size installed at factory Table 4 Part Cat Number Inlet Gas Su...

Страница 8: ... control knob are located below the glass panel enclosure The gas valve for electronic systems is also located below the glass enclosure panel see Figure 1 Reinstalling Control Compartment Door If necessary reinstall the door by inserting the tabs on each side of the door into the corresponding holes in the control compartment opening one side first then the other Swing the door gently up and fast...

Страница 9: ...ves may have a CPI switch located in the lower control compartment Figure 1 This switch allows the pilot to be switched from intermittent mode pilot is extinguished when the fireplace is OFF to continuous mode pilot stays on when fireplace is OFF In periods of extreme cold you may notice condensation on the glass door when the fireplace is OFF and the pilot is in intermittent mode Also with the pi...

Страница 10: ...ent components are properly assembled and not damaged Homeowner must contact a qualified service technician at once if any abnormal condition is observed If the venting system is disassembled for any reason a qualified service technician should follow vent installation instructions for proper reassembly and proper sealing of the venting system components However more frequent periodic inspections ...

Страница 11: ...tre l entretien de l appareil doit être remis en place avant de mettre l appareil en marche WARNING Donotattempttosubstitutethe materials used on this door or replace cracked or broken glass Handlethisglasswithextreme care Glass is susceptible to damage Do not scratch or handleroughlywhilereinstall ing the glass door frame The glass door s of this appli ance must only be replaced as a complete uni...

Страница 12: ...Follows Carefully position the ceramic fiber logs over the burner as shown in Figure 9 Logs should be placed in the order shown and per the fol lowing instructions 1 Place the rear log 1 as shown Position it on the left rear log bracket 2 Placetheleftfrontlog 2 asshown Position it against the left front of the log rack 3 Place the right front log 3 as shown Position it against the right front of t...

Страница 13: ...shown 4 2 1 Right Rear Bracket Rockwool Do Not Place Rockwool Over Burner Slots 1 Right Front Brackets Left Front Brackets 3 1 Right Front Log Nub 2 4 2 Log Number Description 1 Left Front Log 2 Right Front Log 3 Left Rear Log 4 Right Rear Log Position on the left rear log brackets Catalog Number for the entire log set H7244 Position the individual logs as shown below Logs should be placed in the ...

Страница 14: ... Right Front Brackets Left Front Brackets Place Ember Chunk Here Align hole at the bottom of left front log 2 over the left front brackets and the right front log over the right front brackets 3 2 1 Position on the left rear log bracket Rockwool Do Not Place Rockwool Over Burner Slots Figure 10 Catalog Number for the entire log set H7245 Position the individual logs as shown below Logs should be p...

Страница 15: ...2 1 3 4 5 Left Rear Brackets Right Rear Bracket Right Front Brackets Left Front Brackets Center Rear Bracket Rockwool Do Not Place Rockwool Over Burner Slots 2 1 3 1 Center Log Groove 2 Align holes at the bottom of center log 3 over the center and right rear brackets 3 4 Align holes at the bottom of left rear log 4 overtheleft rear brackets Catalog Number for the entire log set H7547 Position the ...

Страница 16: ...emes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning to ensure that the flames are not impinging on any of the logs If the log set is properly positioned and a sooting condition still exists then the air shutter opening should be increased Themoreoffsetsintheventsystem thelarger the air shutter opening will need to be An appliance operated wi...

Страница 17: ... burner refer to the lighting instruc tions on Page 21 Figure 16 Millivolt Pilot 1 Locateadjustmentrodandadjustairshutter to the standard setting as shown in Figure 15 adjustment rod is located in the lower control compartment Note Rotating the adjustment rod down to decrease air and up to increase air 2 Lightappliance followlightingprocedureon lighting label in control compartment or see the ligh...

Страница 18: ...ng parts provide the following information 1 Appliance model number 2 Appliance serial number Onappliancelabeloncontrolcompartmentfloor 3 Part number 4 Part description 5 Quantity required 6 Appliance installation date PRODUCT REFERENCE INFORMATION Model Number_________________________________________________________ Serial Number_________________________________________________________ Date Insta...

Страница 19: ...ch kit can be installed directly in the gas valve mounting bracket millivolt gas valve equipped fireplaces to provide On Off operation in lieu of a wall switch ON OFF and Timer Controls Feature a timed ON OFF mode as well as manual ON OFF operation G Fire Cost Effective Solution Manual ON OFF operation Works with millivolt and low voltage electronic ignition controls Kit includes remote and receiv...

Страница 20: ...dels H8529 APDML30C 30 in Arch Pane Doors Painted SLDVT 30 H8530 APDML30SP 30 in Arch Pane Doors Satin Pewter H8515 APDML35C 35 in Arch Pane Doors Painted SLDVT 35 H8514 APDML35SP 35 in Arch Pane Doors Satin Pewter H8512 APDML40C 40 in Arch Pane Doors Painted SLDVT 40 H8513 APDML40SP 40 in Arch Pane Doors Satin Pewter H8535 APDML45C 45 in Arch Pane Doors Painted SLDVT 45 H8536 APDML45SP 45 in Arch...

Страница 21: ...r kits include ceramic panels as shown here The panels have brick like features in relief ACCESSORY COMPONENTS continued Touch Up Paint Kit Repair of minor scratches and discoloration of the applianceblackpaintedsurfacesmaybeaccomplished with the touch up paint kit Touch Up Paint Kits all models Cat No ModelNo Description 90L73 FTPK B Touch Up Paint Black PA I N T Termination Guard Kits all models...

Страница 22: ...f it goes out repeat steps 5 through 9 If knob does not pop up when released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 10 Turn gas control knob counterclockwise to ON 11 Close control compartm...

Страница 23: ...il sortira subitement La veilleuse devrait rester allumée Si elle s éteint répétez les étapes 5 à 8 inclusivement Si la manette ne se soulève pas d elle même lorsqu on la relâche arrêter et appeler immédiatement un technicien qualifié ou le fournisseur de gaz Si la veilleuse ne reste pas allumée après plusieurs tentatives réglez la manette d admission du gaz à la position OFF et appelez un technic...

Страница 24: ... TO APPLIANCE WARNING HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS 3 Turn off all electric power to the appliance if service is to be performed Note The control may have a battery backup remove batteries if installed 4 Close the main line gas shut off valve P N 580491 01 REV 00 A This appliance is equipped with an ignition device which automaticall...

Страница 25: ...fié et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l eau Module de veilleuse électronique Valve électronique SIT 1 Placez l interrupteur mural ou on off en position off 2 Si applicable Sélectionnez OFF sur le récepteur 3 Coupez l alimentation électrique de l appareil s il faut procéder à l entretien Note Le contrôleur peut avoir une batterie de secours ...

Страница 26: ...raps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate appliance checkout procedure detailed in this manual Replace Glowing Embers Homeowner Qualified Service Technician Remove old ember materials rockwool and vacuum the ember placement area Place new embers as described and shown in Figures 9 and 10 Replace Batteries Hom...

Страница 27: ... ON NOTE If an optional remote switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position A Wall switch or wires defective Check wall switch and wires for proper connections Jumper wire across terminals at wall switch if burner comes on replace defective wall switch If okay jumper wires across wall switch wires at valve i...

Страница 28: ... and gas shutoff valves call a service technician if required C Pilot flame is not engulfing the sensor Call a service technician D Obstructed vent system Call a service technician 4 Soot is present on the glass and panels A Initial fireplace operation A white film may develop on the glass during the first few fires as part of the burn in process The first few times you use the fireplace clean the...

Страница 29: ... 2 H1264 2 H1264 2 H1264 2 5 Log Set Complete H7244 1 H7244 1 H7245 1 H7547 1 6 Burner Assembly H7717 1 H7717 1 H7718 1 H7718 1 7 Orifice Main Burner Natural Gas H4873 1 H1355 1 60J80 1 37L70 1 7 Orifice Main Burner Propane Gas H7838 1 75L10 1 19L52 1 99K79 1 8 Bag of Glowing Embers Rockwool 88L53 1 88L53 1 88L53 1 88L53 1 8 Bag of Decorative Volcanic Stone 80L42 1 80L42 1 80L42 1 80L42 1 9 Orific...

Страница 30: ...fications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNOX and other related LENNOX marks are registered or common law trademarks of Lennox Industries Inc and are used with permission Printed in U S A 2012 2013 Lennox Hearth Products LLC P N 506010 04 Rev A 04 2013 S...

Отзывы: