background image

30

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

SUPERIOR

® 

 DIRECT-VENT GAS FIREPLACES  •  MODELS SLDVT-30/35/40/45  •  CARE AND OPERATION INSTRUCTIONS

REPLACEMENT PARTS 

Dexen Gas

Controls

SIT Gas

Controls

6

10

29

9

7

28

16

17

18

19

15

7

10

(Ref.)

2

1

8

30

4

11

5

31

32

33

3

Содержание SLDVT-30NE

Страница 1: ...is not followed exactly a fire or explosion may result causing property damage personal injury or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALL...

Страница 2: ...otices 6 Appliance Operation Notices 6 Warranty Information 6 General Information 7 General Information 6 Operation Care of Your Appliance 8 Gas Controls Access 8 Variable Flame Adjustment 9 Maintenan...

Страница 3: ...yer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con el vidrio y prevenir las quemaduras y lesiones graves Ver los detalles...

Страница 4: ...haude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette mesure emp chera...

Страница 5: ...erruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la c...

Страница 6: ...s coverage Retain this manual File it with your other docu ments for future reference Failure to comply with the installation and operating instructions provided will result in an improperly installed...

Страница 7: ...10 SLDVT 40 44 0 086 60J80 0 048 99K78 SLDVT 45 0 090 37L70 54 0 055 99K79 Standard size installed at factory Table 4 Part Cat Number SUPERIOR DIRECT VENT GAS FIREPLACES MODELS SLDVT 30 35 40 45 CARE...

Страница 8: ...orintothecorrespondingholesinthecontrol compartment opening one side first then the other To close pull the door gently up and close by pushing forward and pushing the top edge down into the groves at...

Страница 9: ...k Turn unit mounted switch or wall switch to the ON Position Unit should spark at pilot and light Operate Normally Replace batteries if needed Afterpowerisrestored removebatteries Variable Flame Heigh...

Страница 10: ...re initial use and at least annually by a qualified service techni cian inspection should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled a...

Страница 11: ...anels see Figure 6 1 To access the glass door securing latches first open the lower control compartment door Figure 6 by lifting and pulling the bottom panel forward 2 Pullthelatchesforwardanddowntore...

Страница 12: ...andprove hazardous to your safety Iflogsarenotinstalledaccord ing to the log installation instructions flame impinge mentandimpropercombustion could occur and result in soot and or excessive productio...

Страница 13: ...1 over the left front brackets and the right front log over the right front brackets 2 Align the hole at the bottom of log 4 over the Nub of log 2 as shown 4 2 1 Right Rear Bracket Rockwool Do Not Pl...

Страница 14: ...Left Rear Log 5 Right Rear Log Catalog Number for the entire log set H7245 4 5 3 2 1 Align the hole at the bottom of log 5 over the Nub of log 3 as shown 3 5 Left Rear Bracket Right Rear Bracket Righ...

Страница 15: ...g set H7547 Rest the bottom of log 5 over the Groove of log 3 as shown Align holes at the bottom of left front log 1 over the left front bracketsandtherightfrontlog 2 overtherightfrontbrackets 5 2 1 3...

Страница 16: ...emes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning to ensure that the flames are not impinging on any of the logs If the log set is properly p...

Страница 17: ...22 Figure 16 Note If the igniter is damaged a replacement kit is available order Catalog Number 87L54 1 Locateadjustmentrodandadjustairshutter to the standard setting as shown in Figure 15 adjustment...

Страница 18: ...s manual Use only parts supplied from the manufacturer Withpropercareandmaintenance yourappli ance will provide many years of enjoyment If you should experience any problem first refer to the troubles...

Страница 19: ...ailedoperat ing instructions Deluxe Remote Control System The Model RCL T Deluxe Remote Control System has all of the features of the standard system along withanaddedeasytoreadLCDscreenwhichpresents...

Страница 20: ...junction with the arch door kits or door frame kits Arch Pane Design Square Pane Design ARCH PANE DESIGN KITS Cat No Model Description Model Series 35 Arch Pane Door Painted 35 Arch Pane Door Satin Pe...

Страница 21: ...L73 FTPK B Touch Up Paint Black PA I N T Termination Guard Kits all models Cat No ModelNo Description H5820 4 5HTSK Termination Shroud 87L02 SV4 5HGS Termination Guard Deluxe 17M52 SV4 5HGS 1 Terminat...

Страница 22: ...1 2 minutes after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 8 If knob does not pop up when released stop and immediately call...

Страница 23: ...ez le enfonc Allumez imm diatement la veilleuse en d clenchant l allume gaz tincelle en poussant le bouton jusqu ce que la veilleuse s enflamme Continuez de tenir le bouton de r glage enfonc pen dant...

Страница 24: ...switch to OFF or set wall thermostat to lowest setting If used remove the batteries from the battery holder 3 This appliance is equipped with an ignition device which automatically lights the pilot D...

Страница 25: ...i vous ne remarquez aucune odeur de gaz passez l tape suivante 7 Tournez la manette de r glage du gaz jusqu la position de marche ON Ne la forcez pas 8 Ouvrez le courant lectrique ON qui alimente l ap...

Страница 26: ...be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place App...

Страница 27: ...low IMPORTANT NOTE If an optional remote switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch...

Страница 28: ...supply to ON Check wire connection Check location of sensor Check vent system for obstructions Check for proper log placement Check for proper air shutter openings A Low voltage or bad lead wires B D...

Страница 29: ...Complete H7244 1 H7244 1 H7245 1 H7547 1 6 Burner Assembly H7258 1 H7253 1 H7259 1 H7550 1 7 Orifice Main Burner Natural Gas H4873 1 H1355 1 60J80 1 37L70 1 7 Orifice Main Burner Propane Gas 35M91 1...

Страница 30: ...ARE NOT TO SCALE SUPERIOR DIRECT VENT GAS FIREPLACES MODELS SLDVT 30 35 40 45 CARE AND OPERATION INSTRUCTIONS Replacement Parts Dexen Gas Controls SIT Gas Controls 6 10 29 9 7 28 16 17 18 19 15 7 10...

Страница 31: ...31 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Notes SUPERIOR DIRECT VENT GAS FIREPLACES MODELS SLDVT 30 35 40 45 CARE AND OPERATION INSTRUCTIONS...

Страница 32: ...Lennox Hearth Products P N 506010 01 Rev F 06 2011 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications and prices and also to disco...

Отзывы: