background image

www.SuperiorFireplaces.com

126697-01A

11

INSTALLATION CLEARANCES

 WARNING: Maintain the 

minimum clearances. If you 

can, provide greater clearances 

from floor, ceiling, and adjoin

-

ing wall.

Carefully follow the instructions below. This 

will ensure safe installation.

Minimum Wall and Ceiling Clearances 

(see Figure 6)

A.  Clearances from the side of the fireplace 

cabinet to any combustible material and 

wall should follow diagram in Figure 6.

 

Example:

 The face of a mantel, bookshelf, 

etc. is made of combustible material and 

protrudes 3 

1

/

2

" from the wall. This com

-

bustible material must be 4" from the side 

of the fireplace cabinet (see Figure 4).

B.  Clearances  from  the  top  of  the  firebox 

opening to the ceiling should not be less 

than 42".

C.  When the firebox is installed directly on 

carpeting, tile or other combustible mate-

rial, other than wood flooring, the firebox 

should be installed on a metal or wood 

panel extending the full width and depth 

of the enclosure.

D.  Clearances from the bottom of firebox to 

the floor is 0".

These  fireboxes  can  be  installed  as  free

-

standing units against a wall with approved 

cabinet mantels that may be available from 

your retailer or supplier, or as a built-in unit. 

The clearances are the same for either instal-

lation method.

INSTALLATION

Continued

Mantel Clearances for Built-In 

Installation

If placing custom mantel above built-in fire

-

box, you must meet the minimum allowable 

clearance between mantel shelf and top of 

firebox opening shown in Figure 7. These are 

the  minimum  allowable  mantel  clearances 

for a safe installation. Use larger clearances 

wherever possible to minimize the heating of 

objects and materials placed on the mantel.

 CAUTION: Do not allow the 

vent-free gas log heater to touch 

or extend beyond the fireplace 

screen.

NOTICE: Surface temperatures 

of adjacent walls and mantels 

become hot during operation. 

Walls and mantels above the 

firebox  may  become  hot  to 

the touch. If installed properly, 

these temperatures meet the 

requirement of the national 

product standard. Follow all 

minimum clearances shown in 

this manual.

Figure 7 - Minimum Mantel Clearances 

for Built-In Installation

Supplied

Firebox Hood

Must Be Used

at All Times

Wire-mesh

Screen

Firebox

Noncombustible

Material May

Project Off this

Surface above

the Firebox Hood

Mantel Shelf

Note: Any portion of the

mantel shelf must NOT

extend beyond this profile.

12" 16" 20"

1

/

2

"

3

/

4

"

12"

Note: All vertical

measurements are

from top of fireplace

hood opening to

bottom of mantel shelf.

These minimum

clearances replace any

other recommended

clearances supplied

with your ANSI Z21.11.2

approved gas logs.

Wall board or facing

material (above

firebox) may be of

combustible material,

including decorative

mantel ornaments or

other similar projec-

tions off of the facing

material.

Framing

Material

Figure 6 - Minimum Clearance for 

Combustible to Wall

*Minimum 16" from Side Wall 

Example

*

Содержание P126697-01

Страница 1: ...amage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light...

Страница 2: ...where not prohibited by local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer This firebox has been tested under Z21 91 2007 for use with approvedANSIZ21 11 2deco...

Страница 3: ...as a wood burning fireplace Use only decorative unvented room heaters log sets 2 Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooti...

Страница 4: ...LOCATING FIREBOX PLANNING Plan where you will install the firebox This will save time and money later when you install the firebox Before installation consider the following 1 Where firebox will be lo...

Страница 5: ...01A 5 PRODUCT SPECIFICATIONS 36 MODELS Figure 1 36 Models VRT6036RS VRT6036IS VRT6036RH VRT6036IH 30 1 2 29 30 11 1 8 54 1 2 7 7 8 7 36 45 1 8 35 16 97 16 50 365 16 7 3 8 111 8 3 3 4 4 7 8 36 HEARTH...

Страница 6: ...RODUCT SPECIFICATIONS Continued 42 MODELS Figure 2 42 Models VRT6042RS VRT6042IS VRT6042RH VRT6042IH 4 7 8 54 1 2 7 7 8 7 36 5 16 50 42 51 1 8 32 3 8 3 3 4 30 5 16 8 3 4 13 3 5 16 9 7 16 30 11 1 8 42...

Страница 7: ...PRODUCT SPECIFICATIONS Continued 50 MODELS Figure 3 50 Models VRT6050RS VRT6050IS VRT6050RH VRT6050IH 365 16 50 8 3 4 13 35 16 97 16 59 1 8 50 7 7 8 7 30 54 1 2 11 1 8 32 3 8 3 3 4 38 5 16 4 7 8 50 H...

Страница 8: ...sheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between...

Страница 9: ...e because the actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoi...

Страница 10: ...CAUTION Log heaters installed in this firebox create warmaircurrents Thesecurrents move heat to wall surfaces next to firebox Installing firebox next tovinylorclothwallcoveringsor operating firebox wh...

Страница 11: ...mantel above built in fire box you must meet the minimum allowable clearance between mantel shelf and top of firebox opening shown in Figure 7 These are the minimum allowable mantel clearances for a...

Страница 12: ...ls or wood screws through holes in nailing flange see Figure 10 6 Install and properly test gas log heater Follow installation instructions included with the vent free gas log heater that is being ins...

Страница 13: ...t mantel against a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be avail able from your retailer or custom built for your home 1 Assemble cabinet...

Страница 14: ...l toward the firebox surround Hearth Right Face Slot Figure 14 Slots for Firebrick Walls 3 Secure the firebrick wall using 2 of the retainers provided The bracket will slip underneath the metal lip on...

Страница 15: ...avoid spilling Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Grout all joints wher...

Страница 16: ...end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas applianc...

Страница 17: ...t or has a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only original replaceme...

Страница 18: ...www SuperiorFireplaces com 126697 01A 18 PARTS 36 42 AND 50 MODELS 11 10 11 13 14 15 16 14 3 22 20 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4...

Страница 19: ...x Top 1 20 109457 03 Screen 36 2 109457 02 Screen 42 2 109457 01 Screen 50 2 117556 03 Screen 36 Stainless 2 117556 02 Screen 42 Stainless 2 117556 01 Screen 50 Stainless 2 21 20806 Screen Rod 36 2 11...

Страница 20: ...www SuperiorFireplaces com 126697 01A 20 PARTS 36 42 AND 50 MODELS Picture may vary from actual 1 6 4 3 2 5 7 7 7 8 Note See pages 21 thru 24 for part numbers...

Страница 21: ...ngbone 36 Red 1 125413 01 Rear Stacked 42 Red 1 125425 01 Rear Herringbone 42 Red 1 125437 01 Rear Stacked 50 Red 1 125449 01 Rear Herringbone 50 Red 1 5 124212 01 Right Stacked 36 Red 1 124224 01 Rig...

Страница 22: ...Ivory 1 125413 02 Rear Stacked 42 Ivory 1 125425 02 Rear Herringbone 42 Ivory 1 125437 02 Rear Stacked 50 Ivory 1 125449 02 Rear Herringbone 50 Ivory 1 5 124212 02 Right Stacked 36 Ivory 1 124224 02 R...

Страница 23: ...al or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c dam...

Страница 24: ...THIS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased _____________...

Страница 25: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 26: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 27: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 28: ...126697 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126697 01...