background image

www.SuperiorFireplaces.com

126697-01A

12

NOTICE: If your installation does 

not meet the minimum clear-

ances shown, you must do one 

of the following:

•  raise the mantel to an accept

-

able height

•  remove the mantel

BUILT-IN FIREBOX INSTALLATION

Built-in  installation  of  this  firebox  involves 

installing firebox into a framed-in enclosure. 

This makes the front of firebox flush with wall. 

If installing a mantel above the firebox, you 

must follow the clearances shown in Figure 

7, page 11. Follow these instructions to install 

the firebox in this manner.
1.  Frame in rough opening. The firebox fram

-

ing should be constructed of 2 x 4 lumber 

or  heavier.  Use  dimensions  and  rough 

opening layout in Figure 8. Adjust framing 

so that firebox flushes with finished wall 

surface. If installing in a corner, use dimen-

sions in Figure 9, for rough opening.

2.  Install gas piping to firebox location. See 

Gas Line Installation

 on page 16 and 

Con-

necting to Gas Supply

 in log set owner’s 

manual.

3.  Carefully set firebox in front of rough 

opening with back of firebox inside wall 

opening.

4.  Carefully insert firebox into rough opening.
5.  Attach  firebox  to  wall  studs  using  nails 

or wood screws through holes in nailing 

flange (see Figure 10).

6.  Install and properly test gas log heater. 

Follow  installation  instructions  included 

with the vent-free gas log heater that is 

being installed.

IMPORTANT:

  When  finishing  your  firebox, 

combustible  materials  such  as  wall  board, 

gypsum board, sheet rock, drywall, plywood, 

etc. may be butted up next to the sides and top 

of the firebox. Combustible materials should 

never overlap the firebox front facing.

 WARNING: Do not allow any 

combustible materials to overlap 

the firebox front facing.

IMPORTANT:

 Noncombustible materials such 

as brick, tile, etc. may overlap the front fac-

ing, but should never cover any necessary 

openings.

 WARNING: Do not allow non-

combustible materials to cover 

any necessary openings.

  WARNING:  Do  not  fill  the 

spaces around the firebox with 

insulation or other materials.

 WARNING: Framing may be 

placed or rest against fireplace 

spacer, however; framing must 

never be notched.

 WARNING: Do not alter, cut 

or modify fireplace spacers.

INSTALLATION

Continued

Figure 8 - Framing Dimensions

71" (50" Models)

100" (50" Models)

65" (42" Models)

92" (42" Models)

86.5" (36" Models)

61" (36" Models)

Maintain 1 

1

/

2

"

Clearance at Sides

and Back of Fireplace

1

/

2

" Clearance

Not Required at 

Nailing Flanges 

Figure 9 - Corner Installation

30.125"

59.375" (50" Models)

54.625"

51.375" (42" Models)

45.375" (36" Models)

28.250"

(36" Models)

Содержание P126697-01

Страница 1: ...amage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light...

Страница 2: ...where not prohibited by local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer This firebox has been tested under Z21 91 2007 for use with approvedANSIZ21 11 2deco...

Страница 3: ...as a wood burning fireplace Use only decorative unvented room heaters log sets 2 Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooti...

Страница 4: ...LOCATING FIREBOX PLANNING Plan where you will install the firebox This will save time and money later when you install the firebox Before installation consider the following 1 Where firebox will be lo...

Страница 5: ...01A 5 PRODUCT SPECIFICATIONS 36 MODELS Figure 1 36 Models VRT6036RS VRT6036IS VRT6036RH VRT6036IH 30 1 2 29 30 11 1 8 54 1 2 7 7 8 7 36 45 1 8 35 16 97 16 50 365 16 7 3 8 111 8 3 3 4 4 7 8 36 HEARTH...

Страница 6: ...RODUCT SPECIFICATIONS Continued 42 MODELS Figure 2 42 Models VRT6042RS VRT6042IS VRT6042RH VRT6042IH 4 7 8 54 1 2 7 7 8 7 36 5 16 50 42 51 1 8 32 3 8 3 3 4 30 5 16 8 3 4 13 3 5 16 9 7 16 30 11 1 8 42...

Страница 7: ...PRODUCT SPECIFICATIONS Continued 50 MODELS Figure 3 50 Models VRT6050RS VRT6050IS VRT6050RH VRT6050IH 365 16 50 8 3 4 13 35 16 97 16 59 1 8 50 7 7 8 7 30 54 1 2 11 1 8 32 3 8 3 3 4 38 5 16 4 7 8 50 H...

Страница 8: ...sheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between...

Страница 9: ...e because the actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoi...

Страница 10: ...CAUTION Log heaters installed in this firebox create warmaircurrents Thesecurrents move heat to wall surfaces next to firebox Installing firebox next tovinylorclothwallcoveringsor operating firebox wh...

Страница 11: ...mantel above built in fire box you must meet the minimum allowable clearance between mantel shelf and top of firebox opening shown in Figure 7 These are the minimum allowable mantel clearances for a...

Страница 12: ...ls or wood screws through holes in nailing flange see Figure 10 6 Install and properly test gas log heater Follow installation instructions included with the vent free gas log heater that is being ins...

Страница 13: ...t mantel against a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be avail able from your retailer or custom built for your home 1 Assemble cabinet...

Страница 14: ...l toward the firebox surround Hearth Right Face Slot Figure 14 Slots for Firebrick Walls 3 Secure the firebrick wall using 2 of the retainers provided The bracket will slip underneath the metal lip on...

Страница 15: ...avoid spilling Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Grout all joints wher...

Страница 16: ...end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas applianc...

Страница 17: ...t or has a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only original replaceme...

Страница 18: ...www SuperiorFireplaces com 126697 01A 18 PARTS 36 42 AND 50 MODELS 11 10 11 13 14 15 16 14 3 22 20 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4...

Страница 19: ...x Top 1 20 109457 03 Screen 36 2 109457 02 Screen 42 2 109457 01 Screen 50 2 117556 03 Screen 36 Stainless 2 117556 02 Screen 42 Stainless 2 117556 01 Screen 50 Stainless 2 21 20806 Screen Rod 36 2 11...

Страница 20: ...www SuperiorFireplaces com 126697 01A 20 PARTS 36 42 AND 50 MODELS Picture may vary from actual 1 6 4 3 2 5 7 7 7 8 Note See pages 21 thru 24 for part numbers...

Страница 21: ...ngbone 36 Red 1 125413 01 Rear Stacked 42 Red 1 125425 01 Rear Herringbone 42 Red 1 125437 01 Rear Stacked 50 Red 1 125449 01 Rear Herringbone 50 Red 1 5 124212 01 Right Stacked 36 Red 1 124224 01 Rig...

Страница 22: ...Ivory 1 125413 02 Rear Stacked 42 Ivory 1 125425 02 Rear Herringbone 42 Ivory 1 125437 02 Rear Stacked 50 Ivory 1 125449 02 Rear Herringbone 50 Ivory 1 5 124212 02 Right Stacked 36 Ivory 1 124224 02 R...

Страница 23: ...al or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c dam...

Страница 24: ...THIS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased _____________...

Страница 25: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 26: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 27: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 28: ...126697 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126697 01...

Отзывы: