H07023380 / DT2000477-03
English
Description of activity
Display
SMOKE CHAMBER PRESSURE
DT2011666-00
Remember to maintain the safety distances indicated previously.
Be careful, take all due precautions and always comply with the instructions.
If during operation smoke leaks from any part of the stove or the fl ue, shut the stove down immediately and ventilate the room. When the stove has cooled,
check for the cause of the leak and if necessary call in specialist personnel.
The stove is fi tted with several safety devices to guarantee safe operation.
During operation some parts of the stove (door, handle, ceramic parts) can reach high temperatures.
The safety devices are fi tted to eliminate the risk of injury to people and pets and damage to property. Tampering or work carried out
by unauthorised personnel can jeopardise this function.
6.12 SAFETY DEVICES
DT2010223-01
On request the stove may be supplied with a remote control, which can be
used to govern certain stove functions.
-
Startup/Shutdown
: by pressing the two + keys simultaneously the stove
can be turned on or off.
-
Power level:
when operating normally, pressing the + and - keys above
the fl ame symbol will select one of the four power levels of the stove.
-
Temperature
: when operating normally, pressing the + and - keys above
the thermometer symbol will select the desired room temperature (7°C -
30ºC).
6.11 REMOTE CONTROL (OPTIONAL)
DT2011646-00
DT2030079-0
SUPERIOR
+
+
-
-
Fig. 46
WHAT TO DO
- Shut down the stove by holding the ON/OFF key down for several seconds.
- The alarm will stop.
- Call the After-Sales Service Centre.
WHAT TO DO
- Shut down the stove by holding the ON/OFF key down for several seconds.
- The alarm will stop.
- Wait until combustion of any pellets remaining in the grate has fi nished.
- After having cleaned the grate, restart the stove by pressing the ON/OFF key. (The readout ALL
must no longer appear on the display. If this is not the case call the After-Sales Service Centre).
The pressure switch is connected to the fl ue gas outlet, its function is to control the vacuum
inside the outlet duct so that the stove can be used in all safety.
The pressure switch is activated if there is a change in the conditions required for correct
operation in the fl ue gas outlet duct (incorrect installation, blockages or obstructions in the
fl ue, poor maintenance, unfavourable weather conditions such as persistent wind, etc.) the
pressure switch cuts off the power supply to the fuel-loading auger, thereby stopping the
supply of pellets to the grate and starting the stove shutdown process.
- The readout ALL appears on the right display and the time (e.g.: 12:30) or the temperature
on the left display, depending on the initial settings.
- The readout “ALL” appears in the STATE STOVE
(
stove status) mode.
- After approx. 30 seconds the alarm buzzer sounds (if activated).
At the time of stove startup, correct pressure-switch operation is checked so that the appliance
may be used in all safety.
- If any irregularity is found in the pressure switch, the readout ALL (in the case of pressure
switch failure) appears on the right display and the time (e.g.: 12:30) or the temperature on
the left display, depending on the initial settings.
- The readout “ALF 2” appears in the STATE STOVE (stove status) mode.
- After approx. 30 seconds the alarm buzzer sounds (if activated).
31