H07023380 / DT2000477-03
English
Description of activity
Display
POWER SUPPLY CUTOFF
DT2011665-01
Description of activity
Display
Stove operation can be regulated by any kind of external room thermostat connected to
the electronic board.
To connect the thermostat, see paragraph “
INSTALLING THE EXTERNAL ROOM
THERMOSTAT
”.
EXTERNAL THERMOSTAT
DT2011663-00
Operation of the external thermostat depends on the stove temperature setting.
- If the set stove temperature is less than the room temperature, the external thermostat
prevails. (It is advisable to set a minimum value of 7°C for the stove).
- If the set stove temperature is more than the room temperature, the internal stove
thermostat prevails. The external thermostat is disabled.
- If the room temperature is less than the temperature set on the external thermostat, the
readout TON appears on the left-hand display.
- The readout “TON” appears in the STATE STOVE (Stove status) mode.
The room sensor must be connected. If the room sensor is not connected the
appliance does not change the power and operates to user settings.
Description of activity
Display
EMERGENCY LIGHTING OF STOVE
DT2040098-00
If the glow plug is not working, the stove may be lit manually as follows:
- pour a small quantity of pellets into the grate;
- use a lit piece of fi relighter (diavolina) to ignite the pellets;
- close the door;
- start the stove using the ON/OFF button.
This procedure is only to be carried out in an emergency while waiting for the servicing technician to arrive.
If there is a blackout while the stove is in operation, there are two possibilities of procedure
according to stove set-up:
- blackout without timer thermostat settings;
- blackout with timer thermostat settings.
Blackout without timer thermostat settings.
When the electricity supply is restored, the appliance restarts automatically.
• The grate cleaning phase activates.
• The fan operates at full speed to allow the stove to cool.
• The automatic stove restart cycle starts (the steps detailed in the ‘STARTUP’ phase are
repeated automatically).
• Once the ignition cycle has been completed the stove operates normally at power level 2.
Blackout with timer thermostat settings.
There are 3 possible situations.
• Blackout straddling the time set for ignition: the stove does not restart.
• Blackout straddling the time set for shutdown: the stove restarts when the electricity
supply is restored.
• Blackout within the programmed operating time band: the stove restarts when the
electricity supply is restored.
Restarting is carried out with the same procedure as listed in “
Blackout without timer
thermostat settings
”.