background image

SuperiorFireplaces.us.com

900463-01A

20

INSTALLATION

Continued

Figure 27

. Place this log on the base as 

shown in fi gures.

5.  Find the middle split log (LMF24GTA/B  

o r   L M F 2 4 M O A / B   m o d e l s :   D - 0 6 3 , 
LMF30GTA/B or  LMF30MOA/B models: 
D-021, LMF36GTA/B or LMF36MOA/B 
models: D-028). See 

Figures 28 and 28A

The split side of the log faces forward. The 
log has a notch that fi ts around the burner 

Figure 26B - Installing Front Left Log

Grate Finger

Log Slot

Charred 
Log

Log Notch

Right Front Log

Figure 27 - Installing Charred Log

Figure 27A - Installing Charred Log Top 

View

Figure 27B - Installing Charred Log Top 

Side View

 Square Grate

Log Notch

tube on the right side. The left side of the 
burner tube fi ts into the notch on the back 
side of this log. The log is placed properly 
when it sits parallel  to the tube burner and 
the square peg is pointing up. See fi gures 
for reference.

6.  Find the right split crossover log (D-022)  

The bottom of the log has a rectangular 
stand off that fi ts in the slots on the right 
side of the front right log and the middle split 
log. Place this log as shown in 

Figure 29

.

7.  For GTA/GTB logs, fi nd the front top log 

Figure 28 - Installing Middle Split Log 

(D-021)

Middle Split Log (D-063, 
D-021 or D028)

Square Peg

Figure 28A - Installing Middle Split Log 

Rear Top Side View

Log Notch

 Burner Tube

D020

Содержание MNF24INM

Страница 1: ...llow safety warnings exactly could result in serious injury death or property damage INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference This appliance may...

Страница 2: ...ed appli ance It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on...

Страница 3: ...nd liquids WARNING Thisproductcon tainsand orgenerateschemicals known to the state of California to cause cancer or birth defects or other reproductive harm IMPORTANT Read this owner s manualcarefully...

Страница 4: ...ar products turn appliance off If heated the vapors from these prod ucts may create a white powder residue within burner box or on adjacent walls and furniture 10 This appliance needs fresh outside ai...

Страница 5: ...hand held thermostat may not be used where vented decorative list ing is required Variable remote control models include a ther mostat remote control UNPACKING CAUTION Donotremovethe data plates from...

Страница 6: ...nces PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation All spaces in homes fall into one of the three followi...

Страница 7: ...installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu hr 4 8 m3 per kw of the aggregate input rating of all appliances installed in that...

Страница 8: ...so remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Figur...

Страница 9: ...on air may cause mildew to form from too much moisture See Air for Combustion and Ventilation Page 6 CHECK GAS TYPE Use the correct type of gas natural or propane LP If your gas supply is not the corr...

Страница 10: ...Clearances If Not Using Mantel NOTE If using a mantel proceed to If Using Mantel If not using a mantel follow these instructions You must have noncombustible material s above the fireplace opening No...

Страница 11: ...e Flooring NOTICE Surface temperatures ofadjacentwallsandmantelsbe comehotduringoperation Walls and mantels above the firebox may become hot to the touch If installed properly these tem peratures meet...

Страница 12: ...mper clamp will keep damper open Installation instructions are included with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clamp so the minimum perm...

Страница 13: ...rtar joint of bricks 4 Remove appliance base from fireplace 5 Drill holes at marked locations using 3 16 drill bit 6 Attachbase throughholesinbacksidepan els of base to fireplace floor using masonry s...

Страница 14: ...iameter or greater to allow proper gas volume to appliance If pipe is too small undue loss of volume will occur Installation must include an equipment shutoff valve union and plugged 1 8 NPT tap Locat...

Страница 15: ...valve control valve and equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig 3 5 kPa will damage appliance regulator 2 Cap off open end of gas pipe where equip ment...

Страница 16: ...ontrol accessories are available separately see Accessories Page 41 Read instructions shipped with remote control along with instructions below before attempting installation 1 If unit is already inst...

Страница 17: ...your selector switch is in OFF posi tion before installing or chang ing batteries in your hand held remote or receiver Hand Held Remote Control The hand held remote control uses 3 AAA batteries not in...

Страница 18: ...NE WARNING Failuretoposition thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with thisappliancemayresultinprop erty damage or personal injury Magniflame SERIE...

Страница 19: ...Side View Figure 25 Installing Back Left Log Back Left Log D 060 D 018 or D026 Flat Part of Log Log Notch Burner Tube Figure 25A Installing Back Left Log Figure 25B Installing Back Left Log D 018 Rea...

Страница 20: ...w Figure 27B Installing Charred Log Top Side View Square Grate Log Notch tube on the right side The left side of the burner tube fits into the notch on the back side of this log The log is placed prop...

Страница 21: ...0GTA B or LMF30MOA B models D 023 LMF36GTA B or LMF36MOA B models D 029 SeeFigures31 and31A The left end of this log has a round hole that fitsovertheroundpegthatisonthetopofthe back left log The righ...

Страница 22: ...l not be allowed to come in contact with either the burner ports or flame around base of appliance if desired DO NOT place rock or additional logs on front burner or on logs except as directed above P...

Страница 23: ...control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING Iffireplacehasglassdoors never operate this appliance with glass doors closed If you operate ap pliance with...

Страница 24: ...e running this appliance for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 seconds or more This will allow air to bleed from the gas system 7 Wi...

Страница 25: ...turned off You can now turn burner on and off with hand held remote control unit IMPORTANT Do not leave selector switch in the REMOTE or ON position when pilot is not lit This will drain the battery...

Страница 26: ...r Button Location O F F PILOT O N Control Knob Igniter Button 7 With control knob pressed in press and release igniter button This will light pilot The pilot is attached to the front burner If needed...

Страница 27: ...helps distribute heated air from the fireplace NOTE Periodically check the louvers of the firebox and remove any dust dirt or other obstructions Figure 40 Pilot Natural Propane LP HAND HELD REMOTE OPE...

Страница 28: ...mes through 5 levels see Figure 44 Select manual flame height function by press ing MODE button until a flame is shown in lower left corner of display Use UP DOWN arrow button to set desired flame hei...

Страница 29: ...receiver face plate marked PRG The receiver will beep 3 times to indicate it is ready to accept a new remote transmitter Press the ON OFF button on your remote and the receiver will beep 4 times to co...

Страница 30: ...ctor holder for dust and dirt see Figure 51 3 Blow air through the ports slots and holes in the burner 4 Check injector holder located at end of burner tube again Remove any large particles of dust di...

Страница 31: ...MNF30INV Rating Variable 29 000 40 000 Btu Hr Type Gas Natural Ignition Electronic Manifold Pressure 3 4 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C For purpose of input adjustment To Th...

Страница 32: ...Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Overlap ember material 1 4 see Page 22 1 Reconnect ignite...

Страница 33: ...ol knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas company...

Страница 34: ...moved from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see Pages 9 through 11 4 Clean burners see Clean ing and Maintenance Page 30...

Страница 35: ...1 Gas leak See Warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Hand held r...

Страница 36: ...M MNF24INV MNF24IPM MNF24IPV MNF30INM MNF30INV MNF30IPM MNF30IPV 2 1 3 4 5 6 7 8 9 31 32 33 11 30 12 13 14 15 16 17 18 19 10 20 21 22 23 24 25 26 27 34 28 29 Cat No Model F2088 MNF24INM F2091 MNF24IPM...

Страница 37: ...xtension HI LO 1 9 J3562 Male Connector 1 10 J7716 Tube Inlet 1 11 J6364 Asm Pan Burner 1 12 J6147 Bracket Front Burner 2 13 J3547 Nut Captive Washer 2 14 J4886 Air Shutter 1 15 J6127 Orifice Holder 9...

Страница 38: ...J6517 D 018 J6528 D 026 Log Back Left 1 3 J6698 D 059 J6518 D 017 J6529 D 025 Log Front Left 1 4 J6519 D 020 J6519 D 020 J6519 D 020 Log Charred 1 5 J6699 D 063 J6520 D 021 J6530 D 028 Log Middle Spl...

Страница 39: ...on Page 40 of this manual KEY NO CAT NO Log Id CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J8245 D 061 J8253 D 019 J8259 D 027 Log Front Right 1 2 J8246 D 060 J8254 D 018 J8260 D 026 Log Back Left 1...

Страница 40: ...air parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The i...

Страница 41: ...easy chair EMBER KITS Platimun Embers Cat No J6207 Glowing Embers rockwool Cat No J6208 RECEIVER AND REMOTE CONTROL KIT Cat No F1077 MODEL MRC REMOTE READY MODELS ONLY For all models Allows the firep...

Страница 42: ...______________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________...

Страница 43: ...produce excessive temperatures and could result in a re hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d da...

Страница 44: ...liance model number Appliance serial number Date appliance was Installed Type of gas appliance uses Dealer name IHP reserves the right to make changes at any time without notice in design materials sp...

Отзывы: