Superior MNF24INE Скачать руководство пользователя страница 22

SuperiorFireplaces.us.com

900743-00D

22

OPERATION

Continued

REMOTE CONTROL OPERATION

BASIC CONSTRUCTION

• 

Touch-Screen LCD and three push buttons will allow input from users.

• 

LCD screen will provide system status and input feedback to user.

• 

Backlight will illuminate LCD screen for 5 seconds after any user input – the 1st touch of the LCD 
screen will only illuminate the backlight (will not respond to associated zone function). To activate 
any command, the backlight for the screen must be on and the command must be touched before 
the backlight goes off.

• 

Powered via four AAA sized batteries (6V nominal) with LOW BATTERY INDICATOR (5.0V).

Touch-Screen LCD and Button Layout (Not to scale)

Figure 33 - Touch-Screen LCD and Button Layout 

MODE Zone

ROOM TEMP Zone

TIME/PROG Zone

SET TEMP Zone

FLAME Zone

DOWN Button

UP Button

MODE/SET Button

Cont.

S M T W T F S

AM
PM

ROOM

SET

P1

A

P1

P2

P2

Pilot

:

ON  THERMO  OFF

°

°

u

PROGRAM

MODE/SET 

Содержание MNF24INE

Страница 1: ...ption DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs This is an unvented gas fired he...

Страница 2: ...ilt fireplace or in a listed ventless firebox enclosure It is design certified for these installations in accordancewithANSIZ21 11 2 Exception DO NOT install this appliance in a factory built fireplac...

Страница 3: ...adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition Heater will remain hot for a time after shutdown Allow surface to cool befor...

Страница 4: ...DS safetyshutoffsystem The ODS shuts down the heater if enough fresh air is not available See Air for Combustion and Ventilation Page 6 If heater keeps shutting off see Troubleshooting Page 30 11 Do n...

Страница 5: ...rk Quincy MA 02169 7471 UNPACKING 1 Remove logs and appliance base assembly from carton s COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS These appliances are approved for installation in the US state of M...

Страница 6: ...ions for plumbing electrical and gas lines and at other openings If your home meets all three criteria above you must provide additional fresh air See Ventilation Air From Outdoors Page 8 If your home...

Страница 7: ...ce x 20 Maximum Btu Hr the space can support Example 2560 cu ft volume of space x 20 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free...

Страница 8: ...23 1 NFPA 54 Air for Combustion and Ventila tion for required size of ventilation grills or ducts Figure 2 Ventilation Air from Inside Building Or Remove Door into Adjoining Room Option 3 Ventilation...

Страница 9: ...air exist may discolor walls or cause odors IMPORTANT Vent free appliances add moisture to the air Although this is beneficial installing appli ance in rooms without enough ventilation air may cause...

Страница 10: ...using a mantel follow these instructions You must have noncombustible material s above the fireplace opening Noncombustible materials such as slate marble tile etc must be at least 1 2 thick With shee...

Страница 11: ...ble Flooring 14 Min Combustible Material Noncombustible Material Hearth 5 Min Combustible Material Minimum clearance requirements include any projections such as shelves window sills mantels etc above...

Страница 12: ...needed You must raise the fireplace floor to allow access to heater control panel This will ensure adequate air flow and guard against sooting and controls being damaged Raise fireplace floor with non...

Страница 13: ...hutting off the gas to the appliance Check your building codes for any special require ments for locating equipment shutoff valve to appliances Apply pipe joint sealant lightly to male NPT threads Thi...

Страница 14: ...m by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply pipi...

Страница 15: ...Location Propane LP Supply Tank Equipment Shutoff Valve Figure 16 Checking Gas Joints Natural Gas Only Gas Meter Control Valve Location Equipment Shutoff Valve Open Closed Equipment Shutoff Valve Figu...

Страница 16: ...B LMF24MOA B LMF30MOA B MNF30INE MNF30IPE LMF36GTA B LMF36MOA B INSTALLING LOGS EMBERS AND VOLCANIC STONE LOG PLACEMENT It is very important to install these logs exactly as instructed Do not modify l...

Страница 17: ...22C Installing Right Front Log Side View Figure 23 Installing Back Left Log Back Left Log D 060 D 018 or D026 Flat Part of Log Log Notch Burner Tube Figure 23A Installing Back Left Log Figure 23B Ins...

Страница 18: ...uare peg is pointing up See figures for reference Figure 24B Installing Front Left Log Grate Finger Log Slot Figure 25 Installing Charred Log Figure 25A Installing Charred Log Top View Figure 25B Inst...

Страница 19: ...re 29A Installing Back Top Log Top View Figure 30 Installing Small Left Hand And Right Hand Logs Right Split Cross over Log D 022 Back Top Log D 062 D 023 or D029 For MOA B logs only follow steps 9 an...

Страница 20: ...to hide wires from switch log to control valve Place switch log so the switch is easy to access Two ember materials are supplied with this log set PlatinumBrightEmbersgiveabrightglowappearing as hot c...

Страница 21: ...t time after hooking up to gas supply If so you may have to restart the unit several of times to allow the air to bleed from the system TO TURN OFF GAS TO APPLIANCE 1 Once you have activated the scree...

Страница 22: ...minate the backlight will not respond to associated zone function To activate any command the backlight for the screen must be on and the command must be touched before the backlight goes off Powered...

Страница 23: ...F command if SET TEMP SWING is lower than ROOM TEMP Built in thermostat will measure room tem perature All programming should be written for deg F and converted to deg C when selected Temperatures may...

Страница 24: ...d in the TIME PROG Zone except during Setup operations The day of week will be displayed as one of the following S M T W T F S The time of day will be in 12 hour AM 12 hour PM format Midnight will be...

Страница 25: ...its a flame height setting command to the control module to adjust the Flame A height Available settings are 1 3 with a factory de fault of 3 Refer to the THERMOSTAT Mode section for additional detail...

Страница 26: ...ontrol module press the learn switch and release There should be an audible beep indicating the module is ready to accept a transmitter code Next press the mode set button twice on the transmitter wit...

Страница 27: ...prior to each heating season Blocked air holes will create soot We recommend that you clean the unit every three months during operation and have appliance inspected yearly by a qualified service pers...

Страница 28: ...and let cool Remove blockage blocked burner flame holes will create soot Figure 39 Pilot Inlet Air Hole Your pilot may vary from pilot shown Pilot Air Inlet Hole Pilot Assembly CLEANING AND MAINTENANC...

Страница 29: ...t Outlet Thermocouple To S Terminal on Main Module Main Burner Battery Pack Primary or Backup Dry Contact Switches To Pilot Igniter From Pilot Thermocouple Regulator Inlet Gas Valve Valve Step Motor B...

Страница 30: ...communicating with control module 1 Check batteries and replace if need ed Batteries in the power supply box can be tested with a multimeter at the two connections at the back of the battery housing...

Страница 31: ...power supply box 7 Check the igniter connection at both the control module and the ODS pilot Connect if loose 8 Free igniter cable if pinched by any metal or tubing Keep igniter cable dry 9 Replace wi...

Страница 32: ...ve should be hand tight plus 1 4 to 1 2 turn You should not be able to loosen the thermocouple at the con trol valve with your hand Check the thermocouple terminal connection at the control module If...

Страница 33: ...ltage while the system is lighting under load The system will not function under 3 8 volts and batteries should be replaced if the voltage is under 4 0 volts 3 Check thermocouple terminal con nection...

Страница 34: ...hould work within 20 feet of the burner system If it does not replace the batteries in the remote and battery supply box Burnersystemshutsoff Controlmodule sounds 1 long beep 1 Control module is too h...

Страница 35: ...r Slight smoke or odor during initial operation 1 Residues from manufacturing pro cesses and logs curing 1 Problem will stop after a few hours of operation Appliance produces a whistling noise when bu...

Страница 36: ...om Stop using odor causing products while appliance is running 2 Refill supply tank propane LP only 3 Locate and correct all leaks see Checking Gas Connections Page 14 Applianceshutsoffinuse ODSoperat...

Страница 37: ...kit s can result in poor perfor mance and safety hazards FIREPLACE HOOD BLACK Cat No F1764 Model GA6050 For all models Helps deflect heat away from mantel or wall above fireplace Fits openings 28 to...

Страница 38: ...2087 MNF24INE F2090 MNF24IPE F2093 MNF30INE F2096 MNF30IPE 31 43 9 59 29 24 40 49 54 37 23 26 17 15 58 20 25 54 18 16 58 30 38 62 63 54 WARNING Failuretoposition the parts in accordance with these dia...

Страница 39: ...tter Air 1 18 J5199 Shutter Air 1 18 J5200 Shutter Air 1 20 J5416 Tube Venturi 1 24 J8094 Base 24 30 1 25 J6147 Bracket Front Burner 2 29 J8175 Bracket Right Burner 1 30 J8176 Bracket Left Burner 1 31...

Страница 40: ...7 D 060 J6517 D 018 J6528 D 026 Log Back Left 1 3 J6698 D 059 J6518 D 017 J6529 D 025 Log Front Left 1 4 J6519 D 020 J6519 D 020 J6519 D 020 Log Charred 1 5 J6699 D 063 J6520 D 021 J6530 D 028 Log Mid...

Страница 41: ...OA B LMF30MOA B LMF36MOA B KEY NO CAT NO Log Id CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J8245 D 061 J8253 D 019 J8259 D 027 Log Front Right 1 2 J8246 D 060 J8254 D 018 J8260 D 026 Log Back Left...

Страница 42: ...b site at SuperiorFireplaces us com REPLACEMENT PARTS See Pages 38 41 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through y...

Страница 43: ...produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d d...

Страница 44: ...ealer name Innovative Hearth Products IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Con...

Отзывы: