SuperiorFireplaces.us.com
900743-00D
15
INSTALLATION
Continued
PRESSURE TESTING APPLIANCE GAS
CONNECTIONS
1. Open equipment shutoff valve
(see
Figure 14
).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP supply
tank valve.
3. Make sure control knob of appliance is in the
OFF position.
4. Check all joints from gas meter to equipment
shutoff valve for natural gas or propane/LP sup-
ply to equipment shutoff valve for propane/LP
(see
Figure 15
, or
Figure 16
)
. Apply noncorrosive
leak detection fl uid to all joints. Bubbles forming
show a leak.
5. Correct all leaks at once.
6. Light appliance
(see Operation,
Page 20
).
Check
all other internal joints for leaks.
7. Turn off appliance
(see To Turn Off Gas to Ap-
pliance,
Page 20
)
for Remote models.
Figure 14 - Equipment Shutoff Valve
Figure 15 - Checking Gas Joints (Propane/LP
Only)
Control Valve
Location
Propane/LP Supply
Tank
Equipment Shutoff Valve
Figure 16 - Checking Gas Joints (Natural Gas
Only)
Gas Meter
Control Valve
Location
Equipment
Shutoff Valve
Open
Closed
Equipment
Shutoff Valve
Figure 17 - Control Module
Connect Battery Plug Here
POWER SUPPLY AND BATTERY INSTAL-
LATION
It is helpful to have a fl ashlight so you can see the
connections as described below. Locate the battery
power supply. It is the black box with the red and
black wires. Locate the control module
(see
Figure
17
).
Connect the battery power supply to the con-
trol module by plugging the battery power supply
to the mating receptacle on the control module.
The receptacle is located on the side of the black
control module next to the word “BATT” which is
molded in the control module’s black housing
(see
Figure 17
)
. Be certain to push the plug fully into
the receptacle. Install batteries in the battery power
supply and hand held remote control. Place the
battery box so it is located away from the burner
as much as possible towards the back left side of
the fi replace fl oor.