background image

14

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM

Note: 

Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in

the “ON” position.

Important:

 Valve system troubleshooting should only be accomplished by a qualified service technician.

CORRECTIVE ACTION

SYMPTOM

A.

Defective Ignitor

     (no spark at electrode)

B.

Defective or misaligned
electrode at pilot (spark at
electrode).

C.

Gas supply pressure errant.

D.

Pilot orifice plugged.

A.

Defective pilot generator
(thermopile) or remote wall
switch wiring.

B.

Defective automatic valve
operator.

C.

Defective limit switch.

A.

Wall switch or wires
defective.

B.

Pilot generator may not be
generating sufficient
millivoltage.

C.

Plugged burner orifice.

A.

Pilot flame may be too low or
blowing (high) causing the pilot
safety to drop out.

Check for spark at electrode and pilot; if no spark and electrode wire
is properly connected, replace the ignitor.

Using a match, light pilot. If pilot lights, turn off pilot and trigger the
red button again. If pilot lights an improper gas mixture caused the
bad lighting and a longer purge period is recommended. If pilot will
not light check gap at electrode and pilot - should be 

¹⁄₈

"

(3 mm) to have a strong spark. If gap measures 

¹⁄₈

", replace pilot

assembly 

(Figure 11 on page 7)

.

Check inlet gas pressure. It should be within the limits as marked on
the rating plate.

Clean or replace pilot orifice.

Check pilot flame. It must impinge on pilot generator 

(Figure 11 on

page 7)

. Clean and/or adjust pilot for maximum flame impingement

on generator.

Be sure wire connections from generator at gas valve terminals are
tight and generator is fully inserted into the pilot bracket.

One of the wall switch wires may be grounded. Remove wall switch
wires from valve terminals. If pilot now stays lit, trace wall switch
wires for a ground. May be grounded to appliance or gas supply.

With pilot operating (lit), check pilot generator with a millivolt meter.
Take reading at generator terminals of gas valve. Should read 325
millivolts minimum while holding valve knob depressed in pilot
position and wall switch “OFF.” Replace faulty generator if reading
is below specified minimum.

Turn knob to “ON,” place wall switch to “ON.” Millivolt meter should
read greater than 100mV.  If reading is OK and the burner does not
come on, replace the gas valve.

Reset the limit switch button.  If still not working,

 

isolate the limit

switch.  Disconnect the wires from the “ON/OFF” switch and the valve
(label wires for reattachment). Test for continuity with a multimeter.
If continuity is not indicated, switch is defective and must be replaced.

Check wall switch and wires for proper connections. Place jumper
wires across terminals at wall switch. If burner comes on, replace
defective wall switch. If OK, place jumper wires across wall switch
wires at gas valve. If burner comes on, wires are defective or
connections are bad.

Re-check Symptom #2.

Check burner orifice for blockage and remove.

Clean/adjust pilot flame for maximum impingement on pilot genera-
tor 

(Figure 11 on page 7)

.

POSSIBLE CAUSES

1.

Spark ignitor will not
light pilot after repeated
triggering of red button.

2.

Pilot will not stay lit
after carefully following
lighting instructions.

3.

Pilot burning, no gas to
burner, valve knob “ON,”
wall switch “ON.”

4.

Frequent pilot outage
problem.

Содержание GHC-5500N

Страница 1: ...t autre appareil POUR VOTRE S CURIT Que faire si vous sentez une odeur de gaz Ne pas tenter d allumer d appareil Netouchez aucuninterrupteur Nepasvousservir des t l phones se trouvant dans le batiment...

Страница 2: ...rate these units Installation must conform to local codes In the absence of local codes installation must comply with the current National Fuel Gas Code ANSI Z223 1 NFPA 54 In Canada the currentCAN CG...

Страница 3: ...VELY PRESSUREDENVIRONMENTS PRESSURE WITHIN THE HOME IS LESS THAN PRES SURES OUTSIDE SIGNIFICANT NEGA TIVELY PRESSURED ENVIRONMENTS CAUSED BY WEATHER HOME DESIGN OR OTHER DEVICES MAY IMPACT THE OPERATI...

Страница 4: ...n be used with an optional remote control kit The appliance main burner may be turned on and off with the wall switch or remote control Electronic Appliance Lighting To light electronic appliances ref...

Страница 5: ...back on The appliance should then relight and remain lit If this does not occur turn off the appli ance and call a qualified service technician Burner Adjustments Flame Appearance and Sooting Proper f...

Страница 6: ...Accomplishing Person Procedure Inspecting Cleaning Burner Logs and Controls Check Flame Patterns and Flame Height Inspecting Cleaning Pilot and Burner Checking Vent System Appliance Checkout Replacin...

Страница 7: ...f a higher than normal temperature is sensed due to a blocked vent or prolonged downdraft the limit switch will open and cause the burner to shut off The pilot flame should be steady not lifting or fl...

Страница 8: ...AUTION THESE CERAMIC FIBER LOGS MUST BE HANDLED CAREFULLY THEY WILL STAND UP INDEFINITELY TO EX TREMETEMPERATURES HOWEVER THEY ARE VERY FRAGILE AND ARE SUSCEP TIBLE TO CRUSHING AND OR BREAKAGE IF HAND...

Страница 9: ..._________ The Type of Gas Your Fireplace Uses ___________________________________ Your Dealer s Name_________________________________________________ When ordering repair parts always give the followi...

Страница 10: ...e safety information above on this page If you do not smell gas go to the next step 7 Push in gas control knob slightly and turn counterclockwise to PILOT 8 Push in control knob all the way and hold i...

Страница 11: ...ontre jusqu la position d arr t OFF Ne forcez pas le bouton 5 Fermez le compartiment de contr le du bas 8 Enfoncez le bouton de r glage jusqu au fond et gardez le enfonc Allumez imm diatement la veill...

Страница 12: ...ely call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS ELECTRONIC 1 For com...

Страница 13: ...lageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural la position d arr t OFF 3 Ouvrez la porte du compartiment de contr...

Страница 14: ...mpingement on generator Be sure wire connections from generator at gas valve terminals are tight and generator is fully inserted into the pilot bracket One of the wall switch wires may be grounded Rem...

Страница 15: ...niter is sparking at the pilot assembly when the ON OFF switch is activated If not undertake the following steps With ON OFF switch OFF remove wire at TR terminal at the ignition control module Discon...

Страница 16: ...with a variable speed wall switch Horizontal Trim Installation There are two 2 optional horizontal trim kits Models 35HTK PB 35HTK SPB available for use with the GHC Series appliance The 35 HTK SPB ki...

Страница 17: ...1 1 d t f e L p o T g o L 1 0 2 3 M 3 1 1 1 0 2 3 M 3 1 1 0 1 y l b m e s s A r e n r u B 1 5 2 4 4 0 1 1 5 2 4 4 0 1 1 1 l l a W h c t i w S l o r t n o C F F O N O 2 7 9 5 2 0 1 2 7 9 5 2 0 1 2 1 t...

Страница 18: ...18 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS MILLIVOLT 12 13 13 23 11 22 20 24 26 25 14 At Rear of FireBox 14 At Rear of FireBox 10 7c 7d 7a 7b...

Страница 19: ...l b m e s s A r e n r u B 1 5 2 4 4 0 1 1 5 2 4 4 0 1 1 1 l l a W h c t i w S l o r t n o C F F O N O 2 7 9 5 2 0 1 2 7 9 5 2 0 1 2 1 t n o r F r e v o C 1 0 8 5 2 0 1 1 0 8 5 2 0 1 3 1 n o i s n e t...

Страница 20: ...o make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 111...

Отзывы: