background image

2

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

TABLE OF CONTENTS

Introduction ..................................... page

2

General Information ......................... page

2

Operation/Care of Your Appliance .... page

3

Gas Controls/Control

Compartment Access ...................... page

3

Combustion Air Controls ................. page

4

Maintenance .................................... page

5

Manual Limit Switch ........................ page

5

Burner Adjustments ......................... page

5

Flame Appearance and Sooting ..... page

5

Adjustment ................................... page

5

Maintenance Schedule ..................... page

6

Log and Rockwool Placement ......... page

7

Millivolt Appliance Checkout ............ page

7

Electronic Appliance Checkout ......... page

7

Wiring Diagrams .............................. page

9

Warranty .......................................... page

9

Product Reference Information ....... page

9

Replacement Parts .......................... page

9

Lighting Instructions – Millivolt ....... page 10

Lighting Instructions – Electronic .... page 12

Troubleshooting Guide – Millivolt ..... page 14

Troubleshooting Guide – Electronic .. page 15

Accessory Components ................... page 16

Replacement Parts List ..................... page 17

WARNING:  IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE.  REFER TO THIS
MANUAL.  FOR ASSISTANCE OR ADDI-
TIONAL INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.

These appliances are designed to operate on
natural or propane gas only. The use of
other fuels or combination of fuels will de-
grade the performance of this system and
may be dangerous.

For elevations of 0-2000 ft. (0-610 m.) the
GHC/GRD-5500 input is 24,000 BTU/HR for
both natural and propane gases.

WARNING:  THESE FIREPLACES ARE
VENTED DECORATIVE GAS APPLIANCES.
DO NOT BURN WOOD OR OTHER MATE-
RIAL IN THESE APPLIANCES.

CONGRATULATIONS!

In selecting this Superior B-vented gas appliance you have chosen the finest and most
dependable fireplace to be found anywhere.  A beautiful, prestigious, alternative to a
wood burning fireplace.  Welcome to a Family of tens of thousands of satisfied Superior
Fireplace Owners.

Please read and carefully follow all of the instructions found in this manual.  Please pay
special attention to the safety instructions provided in this manual.  The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your Superior product.

INTRODUCTION

The millivolt appliances are designed to oper-
ate on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
provides safe, efficient operation.

The electronic appliances are designed to op-
erate on either natural or propane gas. An
electronic intermittent pilot system provides
safe, efficient operation. External electrical
power is required to operate these units.

Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas
Code, ANSI Z223.1 (NFPA 54). (In Canada, the
current CAN/CGA B149 installation code.)  Elec-
trical wiring must  comply with local codes.  In
the absence of local codes, installation must
be in accordance with the National Electrical
Code, NFPA 70 - (latest edition). (In Canada,
the current CSA C22.1 Canadian Electric Code.)

DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.

GENERAL INFORMATION

Note:

 Installation and repair should be per-

formed by a qualified service person. The appli-
ance should be inspected annually by a quali-
fied professional service technician. More fre-
quent inspections and cleanings may be re-
quired due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating
air passage ways of the appliance be kept clean.

S'assurer que le brùleur et le compartiment
des commandes sont propres.  Voir les in-
structions d'installation et d'utilisation qui
accompagnent l'apareil.

Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.

Due to high temperatures the appliance should
be located out of traffic and away from furni-
ture and draperies.  Locate furniture and win-
dow coverings accordingly.

Nominal operating pressures for the manifold
side of the gas control system are; 3.5 inches
water column (6.54 MmHg) for natural gas
models and 10 inches water column (18.69
MmHg) for propane gas models.

Do not use these appliances if any part has
been under water. Immediately call a qualified,
professional service technician to inspect the
appliance and to replace any parts of the
control system and any gas control which
have been under water.

Ne pas se servir de cet appareil s'il a été plongé
dans l'eau, complètement ou en partie.  Appeler
un technicien qualifié pour inspecter l'appareil et
remplacer toute partie du système de contrôle et
toute commande qui ont été plongés dans l'lau.

Table 1 shows the units' factory-installed
gas orifice size for installations at elevations
of 0-2000 feet (0-610 meters).

Table 1

These appliances comply with National Safety
Standards and are tested and listed by Warnock
Hersey (Report No. J20046562) to ANSI ANSI
Z21.50 - 2000 (in Canada, CSA 2.22 - 2000),
and CAN/CGA-2.17-M91 in both USA and
Canada, as vented gas fireplaces.

C

H

G

D

R

G

s

e

i

r

e

S

e

z

i

s

e

c

i

f

i

r

O

n

o

i

t

a

v

e

l

E

t

e

e

F

)

s

r

e

t

e

m

(

.

t

a

N

.

p

o

r

P

0

0

5

5

3

4

#

4

5

#

0

0

0

2

-

0

)

0

1

6

-

0

(

Содержание GHC-5500N

Страница 1: ...t autre appareil POUR VOTRE S CURIT Que faire si vous sentez une odeur de gaz Ne pas tenter d allumer d appareil Netouchez aucuninterrupteur Nepasvousservir des t l phones se trouvant dans le batiment...

Страница 2: ...rate these units Installation must conform to local codes In the absence of local codes installation must comply with the current National Fuel Gas Code ANSI Z223 1 NFPA 54 In Canada the currentCAN CG...

Страница 3: ...VELY PRESSUREDENVIRONMENTS PRESSURE WITHIN THE HOME IS LESS THAN PRES SURES OUTSIDE SIGNIFICANT NEGA TIVELY PRESSURED ENVIRONMENTS CAUSED BY WEATHER HOME DESIGN OR OTHER DEVICES MAY IMPACT THE OPERATI...

Страница 4: ...n be used with an optional remote control kit The appliance main burner may be turned on and off with the wall switch or remote control Electronic Appliance Lighting To light electronic appliances ref...

Страница 5: ...back on The appliance should then relight and remain lit If this does not occur turn off the appli ance and call a qualified service technician Burner Adjustments Flame Appearance and Sooting Proper f...

Страница 6: ...Accomplishing Person Procedure Inspecting Cleaning Burner Logs and Controls Check Flame Patterns and Flame Height Inspecting Cleaning Pilot and Burner Checking Vent System Appliance Checkout Replacin...

Страница 7: ...f a higher than normal temperature is sensed due to a blocked vent or prolonged downdraft the limit switch will open and cause the burner to shut off The pilot flame should be steady not lifting or fl...

Страница 8: ...AUTION THESE CERAMIC FIBER LOGS MUST BE HANDLED CAREFULLY THEY WILL STAND UP INDEFINITELY TO EX TREMETEMPERATURES HOWEVER THEY ARE VERY FRAGILE AND ARE SUSCEP TIBLE TO CRUSHING AND OR BREAKAGE IF HAND...

Страница 9: ..._________ The Type of Gas Your Fireplace Uses ___________________________________ Your Dealer s Name_________________________________________________ When ordering repair parts always give the followi...

Страница 10: ...e safety information above on this page If you do not smell gas go to the next step 7 Push in gas control knob slightly and turn counterclockwise to PILOT 8 Push in control knob all the way and hold i...

Страница 11: ...ontre jusqu la position d arr t OFF Ne forcez pas le bouton 5 Fermez le compartiment de contr le du bas 8 Enfoncez le bouton de r glage jusqu au fond et gardez le enfonc Allumez imm diatement la veill...

Страница 12: ...ely call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS ELECTRONIC 1 For com...

Страница 13: ...lageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural la position d arr t OFF 3 Ouvrez la porte du compartiment de contr...

Страница 14: ...mpingement on generator Be sure wire connections from generator at gas valve terminals are tight and generator is fully inserted into the pilot bracket One of the wall switch wires may be grounded Rem...

Страница 15: ...niter is sparking at the pilot assembly when the ON OFF switch is activated If not undertake the following steps With ON OFF switch OFF remove wire at TR terminal at the ignition control module Discon...

Страница 16: ...with a variable speed wall switch Horizontal Trim Installation There are two 2 optional horizontal trim kits Models 35HTK PB 35HTK SPB available for use with the GHC Series appliance The 35 HTK SPB ki...

Страница 17: ...1 1 d t f e L p o T g o L 1 0 2 3 M 3 1 1 1 0 2 3 M 3 1 1 0 1 y l b m e s s A r e n r u B 1 5 2 4 4 0 1 1 5 2 4 4 0 1 1 1 l l a W h c t i w S l o r t n o C F F O N O 2 7 9 5 2 0 1 2 7 9 5 2 0 1 2 1 t...

Страница 18: ...18 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS MILLIVOLT 12 13 13 23 11 22 20 24 26 25 14 At Rear of FireBox 14 At Rear of FireBox 10 7c 7d 7a 7b...

Страница 19: ...l b m e s s A r e n r u B 1 5 2 4 4 0 1 1 5 2 4 4 0 1 1 1 l l a W h c t i w S l o r t n o C F F O N O 2 7 9 5 2 0 1 2 7 9 5 2 0 1 2 1 t n o r F r e v o C 1 0 8 5 2 0 1 1 0 8 5 2 0 1 3 1 n o i s n e t...

Страница 20: ...o make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 111...