background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

5

Note:

 Install the hearth extension only as illus-

trated.

The safety strips should extend from front of
the fireplace at least 1 

¹⁄₂

" and should extend to

be at least flush with the sides. In the event a
wooden support is used to elevate the fireplace
above the floor, a “Z” type safety strip should be
fabricated and used to protect the front surface
of the wood support as well as the floor beneath
the hearth extension (

Figures 8 and 9 ). The

safety strips should be tacked down to prevent
possible movement.

Note:

 The “Z” type safety strip is not supplied.

1.

 Estimate the total weight of the fireplace

system including chimney and surround ma-
terials such as brick, stone, etc., to be in-
stalled.  Shipping weights for the fireplace
may be found on page 18.

2.

 Measure the square footage of the floor

space to be occupied by the system, surrounds
and hearth extensions.

3.

 Note the floor construction, i.e. 2 x 6’s, 2 x 8’s

or 2 x 10’s, single or double joists, type and
thickness of floor boards.

4.

 Use this information and consult your local

building code to determine if you need addi-
tional support.

CAUTION: DO NOT BLOCK THE HEAT-CIRCU-
LATING AIR INLET AND OUTLET PORTS ON
CIRCULATING MODELS.  DOING SO MAY RE-
SULT IN A POTENTIAL FIRE HAZARD.

If you plan to raise the fireplace and hearth
extension, build the platform assembly then
position fireplace and hearth extension on top.
Secure the platform to the floor to prevent
possible shifting.

CLEARANCES

Minimum clearance to combustibles for the
appliance is as follows: sides and back - 

1

" (25

mm), floor - 0" (0 mm), adjacent wall - 12" (305
mm), ceiling - 37 

¹⁄₂

" (953 mm).

INSTALLING THE FIREPLACE

Step 1.

 Slide the fireplace into prepared fram-

ing or position fireplace in its final position and
frame later.

The fireplace may not be recessed into a com-
bustible floor. Maintain the floor to hearth clear-
ance established by the fireplace lower front
face.

Step 2.

 Insert the provided metal safety strips,

beneath the fireplace as illustrated (

Figures 6, 7

and 8 ). The safety strips should overlap 

¹⁄₂

" for

continual coverage of the floor.

Note:

 Safety strips are not required when fire-

place rests on a noncombustible surface.

ASSEMBLY STEPS

Note:

 The following steps represent the normal

sequence of installation. Each installation is
unique, however, and might require a different
sequence.

1.

 Position firebox prior to framing or into

prepared framing.

2.

 Install the chimney system.

3.

 Connect house wiring to the fireplace for

later attachment of optional blower.

4.

 Install optional outside combustion air kit.

5.

 Plumb gas line if a decorative gas appliance

will be used. (Gas connections should only be
performed by an experienced, licensed/certi-
fied tradesman.)

6.

 Complete the installation, finish wall mate-

rial, surround and hearth extension to your
individual taste.

7.

 Assemble and attach optional glass door

assembly.

Study the three dimensional illustration (

Fig-

ure 1 ) to get a general idea of each element of
your fireplace system.

PRE-INSTALLATION NOTES

The fireplace may be installed directly on a
combustible floor or raised on a platform of an
appropriate height. Do not place fireplace on
carpeting, vinyl or other soft floor coverings. It
may, however, be placed on flat wood, ply-
wood, particle board or other hard surfaces.
Be sure fireplace rests on a solid continuous
floor or platform with appropriate framing for
support and so that no cold air can enter the
room from under the fireplace.

The fireplace may be positioned and then the
framing built around it, or the framing may be
constructed and the fireplace positioned into
the opening.

Usually, no special floor support is needed for
the fireplace, however, to be certain:

Figure 7

Figure 6

1" (25 mm) Space

Metal Safety Strip

Floor

Hearth

Extension

Maintain

1" (25 mm)

Air Space

At Back

And Sides

Top Spacer

Note:  Hearth extensions must not interfere with
          circulating grillwork

Metal Safety Strip

Floor

Hearth

Extension

Platform

1" (25 mm) Space

Maintain

1" (25 mm)

Air Space

At Back

And Sides

Note:  Hearth extensions must not interfere with
          circulating grillwork

Содержание BC-42

Страница 1: ...r or modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components and accessories...

Страница 2: ...hysical damage as a result of handling or transporta tion These items should be inspected by your distributor or qualified factory representative to ensure safe condition When in doubt con sult your d...

Страница 3: ...11 and in accordance with codes such as the BOCA Basic National Codes the Standard Me chanicalCodeandtheUniformBuildingCodes When complete these fireplace systems con sists of five basic sub systems 1...

Страница 4: ...ermal Barrier 8 Level Chase Enclosure A chase is a vertical box like structure con structedtosurroundthefireplaceandchimney Refer to Figure 2 for a typical chase configura tion As with all chimney ins...

Страница 5: ...l safety strips beneaththefireplaceasillustrated Figures6 7 and 8 The safety strips should overlap for continual coverage of the floor Note Safety strips are not required when fire place rests on a no...

Страница 6: ...surface If a wall covering such as drywall is to be attached to the rear wall then the 20 524 mm must be measured from the drywall surface It is important that this dimension be exact If the appliance...

Страница 7: ...Shown FOAK Combustion Air Kit Optional Note All framing dimensions calcu lated for 1 2 dry wall at the fireplace face Ifsheathingthechaseorfinish ing with other thickness materials calculations will...

Страница 8: ...nsions In new construction to determine chimney cen terline useplumblinefromrooforceilingabove fireplace to center of flue collar on fireplace For remodeling plumb to center of flue collar from ceilin...

Страница 9: ...ign which ensures an immediate tight assembly between sections Plan your chimney require ments carefully before assembly as chimney is difficult to disassemble after installation If disassembled the t...

Страница 10: ...ht dam age the chimney section refer to Figure 32 Note If chimney extends more than 8 above roof surface guy wires are also recommended Use three 3 guy wires attach to locking band assembly extend and...

Страница 11: ...Thetopofthechimneymustbeatleast2 above this reference point In all cases the chimney cannotbelessthen3 abovetheroofattheedge of the chimney The 2 in 10 rule is necessary in the interest of safety but...

Страница 12: ...374 31 2 0 1 1 7 380 31 8 1 0 0 8 Step 2 Use Height of Chimney Only column in The Vertical Elevation Chart to determine combinations of chimney used above return elbow to achieve desired heights Refer...

Страница 13: ...35 69 1 0 0 1 0 1 37 73 1 0 0 2 1 0 38 75 1 0 0 0 2 0 39 77 1 0 2 1 1 0 41 80 1 0 1 4 0 0 43 83 1 0 1 0 2 0 44 85 1 0 0 0 1 1 45 87 1 0 0 3 1 0 46 89 1 0 0 1 2 0 48 91 1 0 2 0 2 0 49 94 1 0 1 0 1 1 50...

Страница 14: ...ection Joints No 8 x 1 2 SMS S c r e w s R e q u i r e d A t E v e r y J o i n t P a s t 6 N o S c r e w s R e q u i r e d I n J o i n t s F o r F i r s t 6 o f O f f s e t 4 6 Underside Of Chimney Ch...

Страница 15: ...ck all connections with soap suds leaks will bubble Never test any gas line con nection with a match or open flame This provision is intended for connection to a decorative gas appliance incorporating...

Страница 16: ...of millboard or a du rable noncombustiblematerialhavinganequal or greater insulating value than K 54BTU IN FT2 HR F At no time may a perpendicular side wall be positioned closer than 9 inches Figure...

Страница 17: ...R values are used to determine acceptable combinations of materi als because R values are additive where r and k values are not Hearth Extension Dimensions A 16 B 35 C 8 D 51 A B D C C R value 1 r x...

Страница 18: ...um of all R values is 70 10 068 10 968 This would not be an acceptable combination of material for the hearth extension since the total calculated R value of the materials used is under the required R...

Страница 19: ...63L42 FTF8 CTD Chase Termination Square 63L48 FTF8 CT1 Chase Termination Round 63L45 FTF8 CTDT Chase Termination Square 63L51 FTF8 CT2 Forced Air Blower Kits Single Speed 80L84 FBK 100 Variable Speed...

Страница 20: ...M REV C 11 2003 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your...

Отзывы: