Fire sparks but pilot does not light

• 

No gas to fire, check isolators are open and gas supply is on.

• 

Pipework blockage, clean out.  

• 

Air not fully purged, re purge supply or wait longer.  

• 

Spark earthing to metalwork, reset gap correctly.  

• 

Blocked pilot, clean out internally.

Pilot lights but then goes out

• 

Severe restriction in gas supply: clear obstruction.  

• 

Faulty thermocouple, replace pilot unit.  

• 

Blocked pilot, clean out. 

• 

Blocked lint gauze, clean. 

• 

Hold control knob in for longer. 

• 

Check control knob does not foul indicator plate.

• 

If the pilot will not stay lit there could be a problem with contamination of the gas 

supply, drafts, room size and/or ventilation or  the thermocouple needs replacement.

Modifications are dangerous and can have a serious unseen effect on safety. 

NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT.

Fire does not spark at pilot

• 

HT lead detached, refit.  

• 

Check the spark gap (see section 7.1).

• 

Faulty piezo unit, replace.  

• 

Debris shorting out electrode, clean.  

• 

Spark shorting to metalwork under tray, check routing of HT lead under burner.

Fire runs for a time 

• 

Loose or faulty thermocouple, rectify. 

and then cuts off

• 

Blocked pilot, clean out. 

• 

Fire is sited in a draft.

• 

Door or window has been opened creating a draft.

• 

Wall on which fire is sited has a hole/holes through which there is a draft.

• 

Fire is too close the an air vent.

• 

Fire is sited on disused chimney breast which has not been adequately sealed up.

• 

Dirt or lint in pilot aeration hole or on the lint gauze, clean thoroughly. 

• 

If the pilot will not stay lit there could be a problem with contamination of the gas 

supply, drafts, room size and/or ventilation or  the thermocouple needs replacement.

Modifications are dangerous and can have a serious unseen effect on safety. 

NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT.

Pilot flame shrinks when 

• 

Poor gas flow to fire, check pressure with fire on high.  

fire is on high

• 

If pressure is low, remove any restriction in pipework or valve.

• 

Check all isolators are adequately sized and fully open. 

• 

Check meter pressure is adequate. 

• 

If the pilot will not stay lit there could be a problem with contamination of the gas 

supply, drafts, room size and/or ventilation or  the thermocouple needs replacement.

Modifications are dangerous and can have a serious unseen effect on safety. 

NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT.

Fire smells when first lit or in use

• 

Newness smell from brand new appliance.  

• 

Leakage occurring.  Carry out leakage test and rectify any problems.  

• 

Combustible materials used in incorrect positions.

• 

Airborne substances such as cleaning materials/air fresheners are being drawn 
through the fire.

• 

Other airborne contaminants such as dust, tobacco smoke, paint vapours.

9

©

2011 Focal Point Fires plc.

11.0  TROUBLESHOOTING GUIDE

GB IE

Содержание CORINTHIA BLACK NG

Страница 1: ...thout the prior written permission of Focal Point Fires plc 1 Revision A 10 11 2011 Focal Point Fires plc The products covered by this booklet are protected under patent GB2275331C GB IE BS EN 14829 2007 KM579167 Superior Fires Christchurch Dorset BH23 2BT Tel 01202 588 632 Fax 01202 499326 www superiorfires co uk e info superiorfires co uk INTHE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEERTO INST...

Страница 2: ...sed in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room On first light up of a new appliance burning off of high temperature paint and lubri cants may occur for the first few hours of operation During this period some smoke may be emitted from the outlet grille this sh...

Страница 3: ...t ft3 by 35 3 This appliance may be installed in any room in the home except bathrooms In accordance with BS5871 part 4 installation in bed rooms is permitted If the appliance is to be installed in a bedroom then an electronic carbon monoxide detector complying with the current edition of BSEN 50291 must be installed in the same room as the appliance For maximum safety it is recommended that such ...

Страница 4: ...y cause cracking along the joint line If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed It is important in these circumstances that any vapour control bar rier is not damaged and that any structural members of the house frame are not damaged refer to section 7 ...

Страница 5: ...only on a vertical surface Avoid sloped surfaces Installation onto anything other than a vertical wall may result in fire damage or injury If the appliance is to be mounted on the inner leaf of a conventional cavity brick wall or a solid wall then the wall plugs and fixing screws provided may be used Depending on the condition of the wall it may be necessary to use additional fixings In this situa...

Страница 6: ... approximately ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure To achieve the HIGH setting push the control knob in slightly and continue turning fully anti clockwise to the high position The main burner should light after a few seconds To decrease the setting to low turn the contro...

Страница 7: ...is cold using a damp cloth and mild detergent on most surfaces Advise that on first light up of a new appliance initial curing of high temperature paint and burning off of lubricants may occur for the first few hours of operation During this period some smoke may be emitted from the outlet grille this should be no cause for concern Accordingly the room should be well ventilated with all windows an...

Страница 8: ...he catalysts are inspected for signs of damage and dirt during routine servicing procedures The expect ed life of the catalysts is in excess of 11 000 hours 10 years of normal use After this time the catalysts should be replaced If there are any deposits of dirt or soot on the catalyst they should be cleaned with a soft brush and a vacuum cleaner If removed for cleaning ensure the seals are in goo...

Страница 9: ...ere is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit there could be a problem with contamination of the gas supply drafts room size and or ventilation or the thermocouple needs replacement Modifications are dangerous an...

Страница 10: ...ucts The expected life of the catalyst is in excess of 11 000 hours 10 years of normal use After this time the catalyst should be replaced Should any home improvements be carried out to the property after the fire is installed such as installation of extractor fans for example the fire should be re checked by a competent person for safe operation U S E R I N S T R U C T I O N S 2 0 CLEARANCES TO C...

Страница 11: ...e discoloured This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room This appliance must not be used in bathrooms Refer to section 4 0 of the installation manual for guidance on installat...

Страница 12: ...ridiana and Merrion models TRAY116 Burner unit Corinthia models TRAY111 Burner unit Meridiana and Merrion models F780079 Catalyst seal kit must also be supplied F940136 Seal kit for Catalyst 7 0 SERVICING 8 0 LIST OF REPLACEMENT PARTS 9 0 INSTALLATION DETAILS Installer GAS SAFE registration No Model Fire serial No Name contact details of installer Supplied by 10 0 SERVICE HISTORY Date of service S...

Отзывы: