Do not tighten fully. Before tightening the wall mounting screws fully,
at this stage it is recommended to check the horizontal alignment of
the appliance with a spirit level, as small adjustments can still be made
if necessary. 
When this has been checked, tighten all four fixing screws fully.
To access the upper fixing screws insert a screwdriver through the
round access holes in the front face of the outlet grille (as shown in
figure 5).  These access holes are located in the same position on all
models.

There are no imitation fuel bed components to install. The appliance features a ribbon burner
which is designed to produce a continuous band of flame over its length. 
The burner should be visually inspected to ensure it is free from any foreign matter. 
If it is necessary to clean or dust off the burner then the glass door should be removed by
removal of the four retaining screws. Re-fit the glass door after cleaning or inspection, ensuring
a good seal. The gap between the spark electrode and the pilot should be 3.5 - 4.5mm to pro-
duce a good spark (see figure 6). There should be no need to adjust this.  If under any circum-
stances the piezo electric spark fails, the pilot cannot be lit manually.

Turn on and test the gas supply up to the fire for any leaks, in accordance with the current edition of BS 6891. For Republic of Ireland,
reference should be made to the current edition of IS813 (the relevant standards governing installation).

• 

Corinthia models :

The control knob is located in the centre of the appliance and is normally accessed by swinging the glass

panel upwards from the bottom. The glass panel is not fitted until section 8.3. The control knob is marked as shown in figure 7.

• Meridiana and Merrion models : 

The control knob is located on the lower

right hand side of the outer case. It is of a spherical design and is marked as shown
in figure 8.

•  All models : 

The pilot is visible behind the left hand side of the burner. Push in

and turn the control knob to the SPARK position, and hold there for a few seconds. 

• 

Continue turning anti-clockwise through the two spark clicks to the PILOT light

position, ensuring the pilot has lit. If not, return the knob clockwise, and repeat. 

• 

When the pilot lights after the spark, keep the knob pressed for approximately ten

seconds. Now release the knob and the pilot should stay alight. 

• 

If the pilot is extinguished during use, wait three minutes before repeating the ignition procedure.  

• 

To achieve the HIGH setting, push the control knob in slightly and continue turning fully anti-clockwise to

the high position. The main burner should light after a few seconds. 

• 

To decrease the setting to low, turn the control knob clockwise to the LOW setting.

• 

To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot position and release. 

• 

To turn the fire off, keep the knob pressed in, return to the OFF position and release.

The pressure test point is located on the inlet restrictor elbow in the centre of the burner as shown in figure 9.
Release the pressure test point screw, and attach a pressure gauge.
Light the fire on the HIGH setting. To commission the appliance,
the operating pressure must be in accordance with the figures
stated in section 2.0 of these instructions. The fire is factory set to
achieve the correct flow rates at the specified inlet pressure. 
Any significant variation in the operating pressure could indicate a
supply problem. If the inlet pressure is too high, the gas supply
meter/governor may be set incorrectly.
This should be checked with the fire running and if necessary reset
by the gas supplier.  If the operating pressure is too low, then check
the meter/governor pressure with the appliance running.  If this is
less than the inlet pressure stated in section 2.0 of these instruc-
tions it will need to be reset by the gas supplier.  If the inlet pres-
sure is too low, but the meter/governor pressure is acceptable,
then a problem in the supply pipework is to be suspected.  
Upon satisfactory checking of the inlet pressure, turn the fire off,
disconnect the pressure gauge and refit the test point screw. Light the fire and check for gas soundness. In the event that the inlet
pressure is not in accordance with the figures stated in the data section of these instructions, the appliance must not be com-
missioned, and the problem investigated and rectified.

Figure 5

6

©

2011 Focal Point Fires plc.

7.0 FIXING THE APPLIANCE 

(CONTINUED)

GB IE

Figure 6

Spark gap

7.1 CHECKING THE BURNER AND SPARK GAP

8.0 TESTING AND  COMMISSIONING

8.1 OPERATING THE APPLIANCE

‘OFF’ position

‘SPARK’ position

‘LOW’ position

‘HIGH’ position

Figure 8

8.2 OPERATING PRESSURE

Figure 9

Figure 7

Meridiana and Merrion model shown

Содержание CORINTHIA BLACK NG

Страница 1: ...thout the prior written permission of Focal Point Fires plc 1 Revision A 10 11 2011 Focal Point Fires plc The products covered by this booklet are protected under patent GB2275331C GB IE BS EN 14829 2007 KM579167 Superior Fires Christchurch Dorset BH23 2BT Tel 01202 588 632 Fax 01202 499326 www superiorfires co uk e info superiorfires co uk INTHE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEERTO INST...

Страница 2: ...sed in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room On first light up of a new appliance burning off of high temperature paint and lubri cants may occur for the first few hours of operation During this period some smoke may be emitted from the outlet grille this sh...

Страница 3: ...t ft3 by 35 3 This appliance may be installed in any room in the home except bathrooms In accordance with BS5871 part 4 installation in bed rooms is permitted If the appliance is to be installed in a bedroom then an electronic carbon monoxide detector complying with the current edition of BSEN 50291 must be installed in the same room as the appliance For maximum safety it is recommended that such ...

Страница 4: ...y cause cracking along the joint line If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed It is important in these circumstances that any vapour control bar rier is not damaged and that any structural members of the house frame are not damaged refer to section 7 ...

Страница 5: ...only on a vertical surface Avoid sloped surfaces Installation onto anything other than a vertical wall may result in fire damage or injury If the appliance is to be mounted on the inner leaf of a conventional cavity brick wall or a solid wall then the wall plugs and fixing screws provided may be used Depending on the condition of the wall it may be necessary to use additional fixings In this situa...

Страница 6: ... approximately ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure To achieve the HIGH setting push the control knob in slightly and continue turning fully anti clockwise to the high position The main burner should light after a few seconds To decrease the setting to low turn the contro...

Страница 7: ...is cold using a damp cloth and mild detergent on most surfaces Advise that on first light up of a new appliance initial curing of high temperature paint and burning off of lubricants may occur for the first few hours of operation During this period some smoke may be emitted from the outlet grille this should be no cause for concern Accordingly the room should be well ventilated with all windows an...

Страница 8: ...he catalysts are inspected for signs of damage and dirt during routine servicing procedures The expect ed life of the catalysts is in excess of 11 000 hours 10 years of normal use After this time the catalysts should be replaced If there are any deposits of dirt or soot on the catalyst they should be cleaned with a soft brush and a vacuum cleaner If removed for cleaning ensure the seals are in goo...

Страница 9: ...ere is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit there could be a problem with contamination of the gas supply drafts room size and or ventilation or the thermocouple needs replacement Modifications are dangerous an...

Страница 10: ...ucts The expected life of the catalyst is in excess of 11 000 hours 10 years of normal use After this time the catalyst should be replaced Should any home improvements be carried out to the property after the fire is installed such as installation of extractor fans for example the fire should be re checked by a competent person for safe operation U S E R I N S T R U C T I O N S 2 0 CLEARANCES TO C...

Страница 11: ...e discoloured This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room This appliance must not be used in bathrooms Refer to section 4 0 of the installation manual for guidance on installat...

Страница 12: ...ridiana and Merrion models TRAY116 Burner unit Corinthia models TRAY111 Burner unit Meridiana and Merrion models F780079 Catalyst seal kit must also be supplied F940136 Seal kit for Catalyst 7 0 SERVICING 8 0 LIST OF REPLACEMENT PARTS 9 0 INSTALLATION DETAILS Installer GAS SAFE registration No Model Fire serial No Name contact details of installer Supplied by 10 0 SERVICE HISTORY Date of service S...

Отзывы: