superior fires Belrose Radiant Edwardian F500395 Скачать руководство пользователя страница 6

Note: Ensure that the gas supply is isolated before commencing

installation of the appliance. 

The fireplace opening and environment must be in compliance with specifica-

tions laid down in the appropriate sections of these instructions.

Remove the appliance from it’s carton as described previously and stand upon

a dust sheet or similar. Place the decorative frame, coals, ceramics and fixings

safely to one side. Remove the burner from the assembly by removing the

retaining screws.  

Slide control models : Remove the slide control linkage connecting screw.

The tray is now free, and may be lifted away.

RADIANT PANELS (Radiant models only):  

The three radiant panels may now be fixed

inside the firebox. Select the patterned side of each panel and insert as follows; 

Lay the firebox on it’s back. Lay the tapered panel onto the rear face of the firebox. 

The side panels should be fitted by inserting their front edges into the pre-fitted retaining brack-

ets on the front face of the firebox. Gently align the side panels with the side of the firebox as

shown in figure 3, over the top of the back panel already in place. 

Make sure that the side panels are pushed 

up

firmly to the roof of the firebox, and 

back 

firmly

to retain the tapered panel. Make small adjustments to line up the mortar lines if required. Secure

the side panels using the small ‘L’ shaped brackets and screws provided (figure 4). The screws

should locate into the pre-punched holes in the sides of the firebox.

SUPPLY PIPE ENTRY (All models) : 

Knockout holes are provided in the rear and sides of

the firebox for use where concealed pipework is required. Where necessary,

knock out the appropriate hole with a sharp tap from a hammer, and fit the

rubber grommet supplied. A small incision can now be made in the rubber to

slip snugly around the outside of the pipe and sleeving. 

Do not install or use

the appliance without the seal in place

. If a hole is inadvertently opened,

reseal with an intact grommet. Failure to fit the seal correctly will cause flue

suction to act upon the area under the burner, resulting in poor performance

and intermittent cutting out of the burner.

Slide controls models :

The control knob is supplied as a loose part. Insert

the control knob into the hole in the top of the slide control spindle (Figure

5). Secure the control knob in position using the M4 nyloc nut provided.

SPIGOT RESTRICTOR :

If installing the fire into a Class 1 or good Class

2 flue, simply bend up (stitch bend join) the spigot restrictor into position in

the flue outlet of the fire as shown in figure 6. 

You MUST remove (or bend down fully) the spigot restrictor and

re-test if the appliance fails a spillage test during commissioning. 

SEALING STRIPS : 

Apply the self adhesive sealing strips to the back of

the fireframe as shown in figure 8 to give a continuous seal.

8.0 PREPARING THE APPLIANCE

GB IE

6

© 

2011 Focal Point Fires plc.

Figure 3

Figure 4

Figure 5

Figure 6

Figure 8

Figure 7

Содержание Belrose Radiant Edwardian F500395

Страница 1: ... CHROME NG F500394 BELROSE RADIANT EDWARDIAN BLACK NG F500395 BELROSE RADIANT EDWARDIAN CHROME NG F500396 BELROSE RADIANT SOHO CHROME NG F500397 BELROSE RADIANT VICTORIAN BLACK NG F500398 BELROSE RADIANT VICTORIAN CHROME NG F500399 CASONA RADIANT COAL NG F500400 CASONA RADIANT PEBBLE REMOTE NG F500401 WALTHER CONVECTOR ELYSEE BRASS NG F500402 WALTHER CONVECTOR GROVE BRASS NG F500403 WALTHER CONVEC...

Страница 2: ...battery approximately every twelve months Burner spark generator requirements 1 x PP3 type 9 volt Refer to the appropriate section of these instructions for details of how to change the battery Remote control models This appliance features a battery operated remote control system and under normal usage will need new batteries approximately every twelve months Remote control Handset requirements 1 ...

Страница 3: ...any type of gas fire In some instances of this flue construction temperature cracking of the surface plaster may occur through no fault of the appliance An air gap or some form of insulation material should be installed to prevent normal flue temperatures from damaging wall surfaces Pre cast flues must be checked for mortar fangs and correct installation of joints flue sections in loft space and t...

Страница 4: ...g providing the forward projection does not exceed 100mm Any com bustible side walls must be at least 500mm to the side of the radiant heat source As with all heating appliances any decorations soft furnishings and wall coverings i e flock blown vinyl and embossed paper positioned too close to the appliance may discolour or scorch Radiant models have a mounting depth of 180mm In accordance with BS...

Страница 5: ...lled to allow plugs and screws to secure installation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any back or infill panel Note The DEPTH dimension is inclusive of any back or infill panel Stand the carton the right way up cut the strapping bands and remove the top endcap Read all the instructions before continuing to ...

Страница 6: ...ews provided figure 4 The screws should locate into the pre punched holes in the sides of the firebox SUPPLY PIPE ENTRY All models Knockout holes are provided in the rear and sides of the firebox for use where concealed pipework is required Where necessary knock out the appropriate hole with a sharp tap from a hammer and fit the rubber grommet supplied A small incision can now be made in the rubbe...

Страница 7: ...g When the opening is ready for installation of the fire the gas supply may be routed as per the examples shown in figure 9 IMPORTANT Wherever a concealed connection is made a rubber grommet must be used to seal the firebox The gas pipe must be suitably protected where it passes through fireplace openings Any sleeving should be sealed to the pipe at its ends This appliance is fitted with an inlet ...

Страница 8: ... the inlet restrictor elbow from the inlet pipe Connect the previously installed gas supply to inlet restrictor elbow Place the burner unit into the firebox making sure that the rear lugs locate properly on to the ledge in the firebox Fit the two securing screws through the burner legs to secure the assembly Re fit the restrictor elbow to the inlet pipe of the appliance Please see the relevant sec...

Страница 9: ...the control knob to an inter mediate position To turn the fire OFF move the slide control knob upwards fully to the position marked O The pilot is visible through the left hand side of the front ceramic strip When cold the coals or pebbles may be rotated for good viewing Turn the main burner con trol shown on left hand side of control valve knob fully anti clockwise Turn ignition knob shown on rig...

Страница 10: ...f necessary reset by the gas supplier Upon satisfactory checking of the burner pressure turn the fire off disconnect the pressure gauge and refit the test point screw Light the fire and check for gas soundness In the event that the burner pressure is not in accordance with the figures stated in the data sec tion of these instructions the appliance must not be commissioned and the manufacturer shou...

Страница 11: ...ly clean in the open air Be careful not to create dust from the coals Where necessary replace damaged components with genuine spares Seal scrap ceramic components in plastic bags and dispose at proper refuse sites as directed Re fit the ceramics by referring to the relevant section of these instructions 12 8 TESTING FOR SPILLAGE CONTINUED 11 2011 Focal Point Fires plc GB IE Match Crimp Tube Figure...

Страница 12: ...t using two spanners to make cleaning easier Do not damage or try to remove the pilot injector The unit is factory set and the only check necessary is to ensure the spark gap is correct See specifications for gap setting Remove the burner unit as described previously Protect the hearth from potential damage Unroll the coiled tensioner cables from the rear of the firebox Remove the securing nip ple...

Страница 13: ...Excessive flue pull Fire is too close the an air vent Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit there could be a problem with contamination of the gas supply drafts ventilation or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BENDTHETHERMOCOUPLETO MAKETHE P...

Страница 14: ...f abnormal flue conditions occur It is NOT a sub stitute for an independently mounted Carbon Monoxide detector This fire is supplied with a particular style of firefront Use of the firefront will ensure an adequate airflow under the firebed for the cor rect functioning of this appliance Use ONLY the firefront supplied with the appliance Use of any other firefront could be dangerous Should any home...

Страница 15: ...the control knob to an inter mediate position To turn the fire OFF move the slide control knob upwards upwards fully to the position marked O The pilot is visible through the left hand side of the front ceramic strip When cold the coals or pebbles may be rotated for good viewing Turn the main burner con trol shown on left hand side of control valve knob fully anti clockwise Turn ignition knob show...

Страница 16: ... front coal strip should fit in front of the burner rail Again do not place on top of the burner rails When the front coal is in posi tion bend up the three metal tabs at the front of the tray to retain as shown in figure 8 3 Coals All of the coals are the same Take five coals and place them as shown in figure 9 Care should be taken to ensure that the coals bridge the gap between the front coal an...

Страница 17: ...effect matrix used for pebble effect versions are of the same design as coal effect versions but have a different surface finish Position them as shown in figure 13 2 Open the bag of 16 ceramic pebbles All of these pebbles are the same size Take five pebbles and place them as shown in figure 14 Care should be taken to ensure that the pebbles bridge the gap between the front strip and the four supp...

Страница 18: ... Refer back to section 6 0 Fuel bed layout coal effect option and fol low steps 1 and 2 The fuel effect matrix used for log effect versions is the same design as coal effect versions but has a different surface finish The front log strip is of a different design and must be handled with care Position them as shown in figure 18 2 Open the bag of 9 moulded ceramic logs All of the logs except two are...

Страница 19: ... foreign matter is found on the fire it may indicate a need for servicing Do not use the fire until the source of the debris has been found and rectified Air vents where fitted should be checked periodically to ensure they are free from obstruction Before carrying out any of the following operations ensure that the fire is OFF and completely cold FIREFRONT Any dust accumulating in the firefront ma...

Страница 20: ...30011 Injector stereo 76 manual control models F730091 Injector stereo 81 Remote control models F730046 Injector stereo 82 slide control models F730077 Burner assembly complete manual control TRAYEXCELC Burner assembly complete slide control TRAY087 Burner assembly complete remote control TRAY017 10 0 LIST OF REPLACEMENT PARTS GB IE 11 0 INSTALLATION DETAILS Name contact details of installer Suppl...

Отзывы: