The appliances are designed to be floor mounted. It is not necessary to secure the surround to the wall, provided it is sited on a firm level sur-

face. 

It should be noted that the appliance creates warm convected air currents. These currents move heat from the room surroundings to, and up

the wall surfaces adjacent to the heater. 

Operating the heater where impurities in the air, (such as tobacco smoke) exist, may slightly discolour wall finishing.  Once the suite is in the

desired location check that it is level and it sits firmly on the floor, i.e. does not rock in any direction, and fits squarely against the wall. 

Note: Skirting boards may need to be cut in order to fit the rear of the suite snugly against the wall, Provision must be made in the wall, either

behind the suite, or in one of the sides of the suite to allow the power supply cable to exit. 

DO NOT

-

mount on a wall.

-

recess any part of the appliance into the wall.

site in a position where curtains or drapes could cover the appliance.

-

site in a position where other soft materials could cover e.g. below a coat rack.

-

site behind an opening door where mechanical impact/damage could occur.

-

site where the supply cable would become a trip hazard.

-

sit, stand or forcefully pull on the appliance.

-

obstruct, cover or force items into the openings.

-

use the heater to dry clothes.

site/use in an outdoor location(s).

-

run the supply cable under carpets

.

It is important that the following clearances are maintained from the appliance to combustible materials and are dependant on the desired

mounting location as defined below.

This appliance is designed to be floor mounted only.

The minimum distance from the top of the appliance to a ceiling is 500mm. 

The minimum distance to the sides of the appliance is 100mm.

The minimum distance to the front of the appliance is 500mm.

A shelf of any size or design may me mounted above the appliance.

Caution: This appliance is heavy. Always seek assistance whilst unpacking and/or during installation. 

Read all  the instructions before continuing to unpack or install this appliance. Carefully remove the appliance from its packaging.  Check that

the remaining packaging contents correlate with the component checklist below. Please dispose of all packaging with care at your local recycling

centre.

QUANTITY

DESCRIPTION

1

Fire suite

1

Remote control handset

1

Instruction Booklet

Check that the fan outlet, mounted underneath the appliance, is not covered or obstructed in any way. Ensure the power to the fire is switched

ON.  

REMOTE CONTROL 

POWER - ON/OFF

OFF will cancel the OFF TIMER and the flame brightness slowly fades to OFF.

FLAME BRIGHTNESS (5 settings)

Press 

∧ 

/

∨ 

to adjust the brightness level

FULL (5) - HIGH (4) - MEDIUM (3) - LOW (2) - DIM (1)

HEATING (7 settings)

Press 

∧ 

/

∨ 

to adjust the temperature level 

60

℃/

99°F - 30

℃/

86°F - 28

℃/

82°F - 26

/

78°F - 24

/

75°F - 22

/

71°F - OFF - (LOOP)

4.0 SITE REQUIREMENTS

5.0 CLEARANCES TO COMBUSTIBLE MATERIALS

GB IE

6.0 UNPACKING THE APPLIANCE

©

2015 Focal Point Fires plc.

3

7.0 COMPONENT CHECKLIST

8.0 OPERATING THE APPLIANCE

Содержание avonbury led

Страница 1: ...right in the text images and layout of this booklet is owned by Focal Point Fires plc You are not per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc GB IE MODEL AVONBURY LED MODELS COVERED BY THESE INSTRUCTIONS AVONBURY ELECTRIC SUITE RANGE Superior Fires Christchurch Dorset BH23 2BT Tel 01202 588 632 Fax 01202 499326 www superiorfires co u...

Страница 2: ...heating will result if it is accidentally covered Never immerse the product in water or any other liquids Do not use this heater where it may come into contact with water e g in bathrooms shower rooms etc Do not use the appliance outdoors Before cleaning the appliance ensure it is unplugged from the power and that it is completely cool Do not clean the appliance with abrasive chemicals Never use a...

Страница 3: ...is important that the following clearances are maintained from the appliance to combustible materials and are dependant on the desired mounting location as defined below This appliance is designed to be floor mounted only The minimum distance from the top of the appliance to a ceiling is 500mm The minimum distance to the sides of the appliance is 100mm The minimum distance to the front of the appl...

Страница 4: ... of time If the sequence has been followed correctly and the heaters still fail to function check the power supply cable plug is plugged in at the outlet socket If this is not the cause call an electrician ALWAYS DISCONNECT THE APPLIANCE AT THE SUPPLY OUTLET SOCKET BEFORE UNDERTAKING ANY CLEANING Except for periodic cleaning of dust there are no specific requirements for care other than regular cl...

Страница 5: ...all consumable items such as any ceramics including coals pebbles the matrix front strips side cheeks rear panels and tapered rear panels are not covered by the 3 year guarantee For all Electric fires purchased the 3 year guarantee commences from the date of purchase providing that you can supply the proof of purchase This does not cover consumable items such as pebbles coals or light bulbs Making...

Отзывы: