The appliances are designed to be floor mounted. It is not necessary to secure the surround to the wall, provided it is sited on a firm level sur-
face.
It should be noted that the appliance creates warm convected air currents. These currents move heat from the room surroundings to, and up
the wall surfaces adjacent to the heater.
Operating the heater where impurities in the air, (such as tobacco smoke) exist, may slightly discolour wall finishing. Once the suite is in the
desired location check that it is level and it sits firmly on the floor, i.e. does not rock in any direction, and fits squarely against the wall.
Note: Skirting boards may need to be cut in order to fit the rear of the suite snugly against the wall, Provision must be made in the wall, either
behind the suite, or in one of the sides of the suite to allow the power supply cable to exit.
DO NOT
-
mount on a wall.
-
recess any part of the appliance into the wall.
-
site in a position where curtains or drapes could cover the appliance.
-
site in a position where other soft materials could cover e.g. below a coat rack.
-
site behind an opening door where mechanical impact/damage could occur.
-
site where the supply cable would become a trip hazard.
-
sit, stand or forcefully pull on the appliance.
-
obstruct, cover or force items into the openings.
-
use the heater to dry clothes.
-
site/use in an outdoor location(s).
-
run the supply cable under carpets
.
It is important that the following clearances are maintained from the appliance to combustible materials and are dependant on the desired
mounting location as defined below.
This appliance is designed to be floor mounted only.
The minimum distance from the top of the appliance to a ceiling is 500mm.
The minimum distance to the sides of the appliance is 100mm.
The minimum distance to the front of the appliance is 500mm.
A shelf of any size or design may me mounted above the appliance.
Caution: This appliance is heavy. Always seek assistance whilst unpacking and/or during installation.
Read all the instructions before continuing to unpack or install this appliance. Carefully remove the appliance from its packaging. Check that
the remaining packaging contents correlate with the component checklist below. Please dispose of all packaging with care at your local recycling
centre.
QUANTITY
DESCRIPTION
1
Fire suite
1
Remote control handset
1
Instruction Booklet
Check that the fan outlet, mounted underneath the appliance, is not covered or obstructed in any way. Ensure the power to the fire is switched
ON.
REMOTE CONTROL
POWER - ON/OFF
OFF will cancel the OFF TIMER and the flame brightness slowly fades to OFF.
FLAME BRIGHTNESS (5 settings)
Press
∧
/
∨
to adjust the brightness level
FULL (5) - HIGH (4) - MEDIUM (3) - LOW (2) - DIM (1)
HEATING (7 settings)
Press
∧
/
∨
to adjust the temperature level
60
℃/
99°F - 30
℃/
86°F - 28
℃/
82°F - 26
℃
/
78°F - 24
℃
/
75°F - 22
℃
/
71°F - OFF - (LOOP)
4.0 SITE REQUIREMENTS
5.0 CLEARANCES TO COMBUSTIBLE MATERIALS
GB IE
6.0 UNPACKING THE APPLIANCE
©
2015 Focal Point Fires plc.
3
7.0 COMPONENT CHECKLIST
8.0 OPERATING THE APPLIANCE