background image

Superiorfireplaces.US.com

127055-01C

4

SPECIFICATIONS

WARNING:  DO NOT INSTALL IN SLEEPING 

ROOM OF MOBILE HOMES

CAUTION: THE STRUCTURAL INTEGRITY OF THE MANU-

FACTURED HOME FLOOR, WALL, AND CEILING/ROOF 

MUST BE MAINTAINED

0" TO

BOTTOM

(LEFT SIDE ONLY)

OUTSIDE AIR

BACK AND 

SIDES

3/4" AIR 

SPACE

HEARTH EXTENSION

66" X 20" MINIMUM

12"

EACH SIDE

COMBUSTIBLE

WALL BOARD

TOP SPACERS

0" TO

1" AIRSPACE

TO COMBUSTIBLE

MATERIAL

NO COMBUSTIBLE

MATERIAL ON FACE

NO COMBUSTIBLE

MATERIAL BELOW 

TOP SPACERS

GAS LINE

KNOCK OUT

AIR KIT 

KNOCK OUTS

GAS LINE

STARTER

SECTION

8DM

PIPE

INNER DIA. 

OUTER 

DIA. 15"

KNOCK OUTS

ELECTRICAL

OUTLET

LEFT SIDE

RIGHT SIDE

PERPENDICULAR

NOT LESS

THAN 12" TO

SIDEWALL

41"

48"

42"

8"

39"

12"

48"

36"

24"

8

 

1

/

8

"

10

 

5

/

8

"

12

 

5

/

8

"

10

 

5

/

8

"

6

 

3

/

4

"

14

 

1

/

4

"

2

 

1

/

2

"

29

 

1

/

2

"

22

 

1

/

2

"

11

 

3

/

4

"

46

 

3

/

4

"

1

 

1

/

2

"

12

 

3

/

8

"

 

5

/

8

"

16

 

1

/

4

"

8

 

1

/

8

"

2

 

1

/

2

"

SQUARE CHASE-TOP

TERMINATION

ROUND TOP TERMINATION

Содержание WRE3036RH

Страница 1: ...explosion may result causing property damage personal injury or death AVERTISSEMENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incindie...

Страница 2: ...er control b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous op...

Страница 3: ...treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide...

Страница 4: ...COMBUSTIBLE WALL BOARD TOP SPACERS 0 TO 1 AIRSPACE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STA...

Страница 5: ...Height for Outdoor Installation The minimum height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 8 feet minimum of 4 feet of chimney pipe sections...

Страница 6: ...f Combustible Materials Fireplace Opening Non Combustible Materials Below Top Spacer Upper Section of Fireplace DRAIN PAN DP42 For outdoor installations the fireplace enclosure must allow for adequate...

Страница 7: ...gained after fitting overlaps must be taken into consideration lineal gain and are given in lineal gain chart see Figure 6 Lineal gain is actual measurable length of a part after two or more parts are...

Страница 8: ...R 30 Offset return elbow A section or sections of chimney may be used between offsets and return elbow Transition pipe must be used after elbow offset is attached 1 To achieve desired offset you may i...

Страница 9: ...ntinued Figure 8 Typical Offset Installation 30E 8DM Return Elbow 30E 8DM Return Elbow 30E 8DM Offset Elbow 30E 8DM Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR...

Страница 10: ...ening into a living space above firestop must be placed onto ceiling from below as shown in Figure 10 They also provide complete separation from one floor space to an other or attic space as required...

Страница 11: ...aterial use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of flashing see Figure 14 Use SC1 for al...

Страница 12: ...ne conduit sleeve if using a raised platform add height Provide sufficient gas line into fireplace chamber for fitting OPTIONAL GAS LINE INSTALLATION VENTING INSTALLATION Continued connection see Figu...

Страница 13: ...lass WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF B...

Страница 14: ...t These coverplatesmustbekeptintheproperlocationpriortousingthefireplace See Figure 23 For further operating guidelines instructions and warranty informa tion please refer to your homeowner s guide or...

Страница 15: ...Refractory Textured Red Herringbone 1 11 107816 03 Rear Refractory Textured White Brick 1 108171 03 Rear Refractory Textured White Herringbone 1 107816 02 Rear Refractory Textured Red Brick 1 108171...

Страница 16: ...27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 39 31 7 37 38 36 28 29 24 23 15 PARTS WOOD BURNING FIREPLACE MODELS WRE3042WS WRE3042WH WRE3042RS WRE3042RH MODEL NO CATALOG NO WRE3042...

Страница 17: ...ge 15 Bottom Rear Refractory 1 13 See Page 15 Bottom Front Refractory 1 14 106683 01 Firebox Support Leg 4 15 Damper Can Collar 1 16 107839 01 Screen Rod 2 17 Firebox Top Assembly 1 18 106703 01 Air K...

Страница 18: ...WITH SLIP SECTION RTT 8DM MESH ROUND TOP TERMINATIONS WITH SLIP SECTION RTTL 8DM ACCESSORIES DOUBLE WALL PIPE 12 8DM 12 8HT 18 8DM 18 8 HT 24 8DM 24 8HT 36 8DM 36 8HT 48 8DM 48 8HT ROOF FLASHING 0 TO...

Страница 19: ...delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with the instruc tions...

Страница 20: ...n design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 127055 01 Rev C 06...

Отзывы: