background image

OK

Achieving Clean Burns

Check the exhaust in about 15 to 20 minutes 

(see below). Large amounts of smoke indicate 

an improper burn setting (either too high or too 

low). Adjust and recheck in 5 to 10 minutes.

FUEL

What does “Well-Seasoned” mean?

When a tree is cut down, the wood is green, 

full of sap and moisture. This moisture content 

can exceed 80%, which must be reduced to 

less than 20%. Wood properly seasoned is 

then capable of generating the heat the stove 

was designed to provide.
Green wood does not burn easily.  Attempting to 

burn green wood often results in a lot of smoke 

and very little fire. Time is the most important 

factor in seasoning wood.  Ideally the moisture 

content should be reduced to 11-20%.  

NOTE: 

The use of a firewood moisture meter is rec-

ommended to ensure the firewood contains 

less than 20% moisture.

Seasoning Guide

Softwoods  -  6 months to 18 months

Hardwoods  -  12 months to 24 months
Logs that are 5” diameter across or larger should 

be split in half, three pieces if over 8 inches, and 

four pieces when over a foot across.  If a tree 

has been dead for 2  -  4 years it still needs to 

be cut, split, and seasoned for 6 to 24 months 

depending on the wood.

4' 

4' 

8' 

Standard 

Cord of

Wood

8 Ft. 

(2.4M)

4 Ft. 

(1.2M)

4 Ft. (1.2M)

Figure 3

Figure 2

CAUTION: It is necessary to remove the baffle 

from the top of the firebox before cleaning the 

chimney. See “Top Baffle Removal Prior To 

Chimney Sweep.”

Dealing With a Chimney Fire

Regular chimney maintenance and inspection 

can prevent chimney fires.  If you have a chimney 

fire, follow these steps:

1.  Close the fireplace door and the combustion 

air controls.

2. Alert your family of the possible danger.

3. If you require assistance, alert your fire 

department.

4. If possible, use a dry chemical fire extin-

guisher, baking soda or sand to control the 

fire.  Do not use water as it may cause a 

dangerous steam explosion.

5.  Check outside to ensure that sparks and hot 

embers coming out of the chimney are not 

igniting the roof.

6. Do not use the fireplace again until your 

chimney and fireplace have been inspected 

by a qualified chimney sweep or a Fire 

Department Inspector.

Chimney Maintenance

Regular chimney inspection and maintenance 

combined with proper operation will prevent 

chimney fires. Keep your chimney clean.  Do not 

allow more than 1/16” (1.6 mm) creosote build 

up in your chimney.  The amount of creosote 

will depend on variables such as frequency of 

use and type of fire.  We recommend that you:

A.  Initially inspect the chimney system weekly.  

From this, you will learn how often it will be 

necessary to clean your chimney.

B. Have your chimney cleaned by a qualified 

chimney sweep.  If you wish to clean it 

yourself, we recommend using a stiff plastic 

or non-metallic brush.  If a metal brush is 

used, its size should be slightly smaller than 

the flue to avoid damaging the chimney.  Do 

not use a brush that will scratch the stainless 

steel interior of the chimney.

C. Do not expect chemical cleaners to keep 

your chimney clean.  The rain cap can be 

removed for inspection and/or cleaning of 

the chimney.

     WARNING

Disposal of Ashes:  Ashes should 

be placed in a metal container 

with a tight-fitting lid. The closed 

container of ashes should be 

placed on a noncombustible floor 

or on the ground, well away from 

all combustible materials, pend-

ing final disposal. If the ashes are 

disposed of by burial in soil or 

otherwise locally dispersed, they 

should be retained in the closed 

container until all cinders have 

thoroughly cooled.

     WARNING

When processed solid fuel fire-

logs are used:  Do not poke or stir 

the logs while they are burning. 

Use only firelogs that have been 

evaluated for the application 

in fireplace and refer to firelog 

warnings and caution markings 

on packaging prior to use.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

6

Содержание WCT6920

Страница 1: ...efficient and dependable installation of your fireplace system Please read and understand these instructions before beginning your installation Do not alter or modify the fireplace or its components u...

Страница 2: ...3 4 Tek Screws Ember Strip Top standoff assembly loose on top of unit PARTS REQUIRED Fireplace Model 6 diameter chimney United States Model IHP Snap Pak including Chimney lengths Elbows where necessa...

Страница 3: ...e it is burning WARNING Always ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the sel...

Страница 4: ...ne normally used since it will deposit the least amount of creosote on the glass and in the chimney The combustion air control must be 3 4 closed and pushed in to close the air boost The precise WARNI...

Страница 5: ...protectors metallic paper coal plastic waste beach wood Christmas tree sul phur and or oil will damage the fireplace G Donotburndriftwoodwhichhasbeeninthe ocean or salt water The salt will corrode th...

Страница 6: ...trol the fire Do not use water as it may cause a dangerous steam explosion 5 Check outside to ensure that sparks and hot embers coming out of the chimney are not igniting the roof 6 Do not use the fir...

Страница 7: ...hardwoods as compared to softwoods or to greenorfreshlycuthardwoods DONOTBURN Garbage Lawn clippings or yard waste Materials containing rubber including tires Materials containing plastic Wastepetrole...

Страница 8: ...ace The fireplace cannot be operated with out door Consult your dealer to select the correct replacement door Important Toassureproperalignment of glass doors Install this fireplace in a square and pl...

Страница 9: ...r half must extend on the floor over which the hearth extension will be built see Figure 8 The safety metal strip must cover the entire width of the fireplace The combustible floor in front of the fir...

Страница 10: ...to consideration the location of the hot air ducts optional outside air kit and chimney Ifpossible youshouldchoosealocationwhere thechimneywillpassthroughthehousewithout cutting floor or roof joists s...

Страница 11: ...lap any facing material installed on the front of the fireplace If thicker material is installed use the facade as a template andmakesureitcanbeeasily removed for servicing 2013 Corner Installation 1...

Страница 12: ...l or Any Rigid Material 2 x 4 Fireplace 1 2 Plywood 6 8 Min Firestop Floor Ceiling Wall Insulate Joists Same As Ceiling Draft Stops Firestop CTDT Termination Note Non Combustible Chase Flashing Must B...

Страница 13: ...ompletely cover the holes in the nailing flanges SIDES Secure the sides of the fireplace to the side framing using the side nailing flange as semblies shown in Figure 13B Fireplace Side Nailing Flange...

Страница 14: ...the blower requires servicing 1 De energize the power to the unit at its source 2 Open the door Figure 17A 3 Remove both andirons from inside the firebox Figure 17A 4 Removethebottomrefractorypanels...

Страница 15: ...en the flexible pipe and the air inlets Carefully push the insulation and plastic cover back over the pipe Using aluminium tape fasten the plastic cover in place Figure 19A Outside Connection Figure 1...

Страница 16: ...EPA Heatflo Conv Kit Table 2 GENERAL INFORMATION If you encounter any problems need clarification of these instructions or are not qualified to properly install this kit contact you local distribu tor...

Страница 17: ...ireplace and outlet locations prior to ducted flex kit installation 2 Remove the two 8 diameter cutouts on top of the fireplace Then cut the insulation in order to obtain two 8 diameter openings and r...

Страница 18: ...etis68 1 7m with the minimum distance from the center of outlet to the ceiling and for the center of the outlet to a side wall of 11 279mm Do not connect the hot air ducts to a central heating system...

Страница 19: ...chimney supported by the supports The maximum chimney length that can be supported by the fireplace is nine 9 feet 2 75 m 6 The chimney must extend at least three 3 feet 915 mm above its point of cont...

Страница 20: ...er of equal size to the joist should be used Figure 26 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 27 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney Flue Diameter 6 A 12 7...

Страница 21: ...ance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessa...

Страница 22: ...all the next SP chimney section through the roof See Figure 32 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk aro...

Страница 23: ...verse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support...

Страница 24: ...e is normally supplied with a chimney adaptor suitable for use with IHP SnapPak venting In Canada the use of Security Chimneys ASHT adaptor is required Security part number 6IHP1 or 6IHP2 One inch wal...

Страница 25: ...ase the size of the hole until a 30 liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip through the hole a 30 lin...

Страница 26: ...g UZI UZI EPA Fireplace HeatFlo Convection Kit EPA Heatflo Conv Kit EPA HEATFLO KIT F3790 OPTIONAL INSTALLATION ACCESSORIES Fireplace Kits Description Cat Part No Central Forced Air Kit Accessories Ce...

Страница 27: ...eeve F4189 Top Standoff Header Shield Assy F4713 Damper Rod H8393 SPECIFICATIONS REPLACEMENT PARTS LIST Cat No Model No F4482 WCT6920WS Contact an IHP dealer to obtain any of these parts Never use sub...

Страница 28: ...our Security Chimneys or DuraVent Distributor or Dealer for ordering information 450 973 9999 1 800 361 4909 USA 1 800 667 3387 Canada 1 800 835 4429 Security Chimneys 2125 Monterey Laval Quebec Canad...

Страница 29: ...ation test emission value 1 9 g hr per 2020 NSPS cordwood Valeur d mission du test d homologation 1 9 g h selon la norme 2020 NSPS Date of Manufacture Date De Fabrication 2021 2022 2023 JAN FEB MAR AP...

Страница 30: ..._____________________________________________ ______________________________________________________ ______________________________________________________ ____________________________________________...

Страница 31: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Страница 32: ...r any questions or concerns REPLACEMENT PARTS See Page 20 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP dis...