SAFETY / LISTING LABEL
WCT6920WS
Model / Modèle: WCT6920WS
Serial No. Numéro de série
CLEARANCES TO COMBUSTIBLES:
SID
E
W
AL
L
(FR
OM
F
IR
EBOX
OPENI
NG
)
24 in. (610 mm)
FRAME HEIGHT OPENING
56 in. (1422 mm)
BACK
W
ALL (FROM S
TANDOFFS)
0 in.
(0 mm)
CEILING HEIGHT (FROM BASE OF
FIREPLACE)
6
ft.
8
in.
(2032
mm)
CHIMNEY
2 in.
(51 mm)
DÉGAGEMENTS AUX COMBUSTIBLES:
MUR L
ATÉRAL (À
PA
RTIR DE
L’OUVE
RTURE DE LA
CHAMBRE DE COMBUSTION)
24 po.
(610 mm)
OUVE
RTURE HAUTEUR DU CADRE
56 po. (1422 mm)
MUR ARRIÈRE (À
PA
RTIR DES ENTRETOISES
DE DÉGAGEMENT)
0 PO.
(0 MM)
AU-DESSUS DU FOYER (À
PA
RTIR DE LA BASE
DU FOYER)
6 pi. 8 po. (2032 mm)
CHEMINÉE
2 po.
(51 mm)
LISTED
FACTO
RY BUI
LT FIREPLACE
FOYER PRÉ
FABRIQUE HOMOLOGUÉ
Manufactured by / Fabriqué par: INNO
VA
TIVE HEA
RTH PRODUCTS
1502 14th St. NW
Auburn,
W
A 98001 USA
P/N 901145-00,
RE
V. 0, 03/2021
•
POUR USAGE
AVEC LE BOIS SEULEMENT
•
UN
TABLIER
NON
COMBUSTIBLE
DOIT
ÊTRE
INS
TALLÉ
À
L’
AV
ANT
DE
L’AP
PAREIL
S’ÉTENDANT
DE
18
“(457
MM)
À
L’
AV
ANT ET
AVOIR UNE LARGEUR D’AU MOINS
39” (991 MM).
•
LE
S M
ANT
EA
UX DE
CHE
M
IN
ÉE
D
OI
VE
NT Ê
TRE N
ON C
OM
-
BU
STI
BL
ES
.
•
AV
ER
TI
SSE
M
ENT
:
CE
FOYER
N’EST
P
AS
HOMOLOGUÉ
POUR
ÊTRE
UTILISÉ
A
VEC
UN
ENSEMBLE
DE
BÛCHES
À
G
AZ
SAN
S
CONDUI
T
D’
ÉV
ACU
AT
ION
.
AF
IN
D
E
RÉDUIRE
LES
RISQUES
D’INCENDIE
OU
DE
BLESSURES,
N’INS
TALLEZ
P
AS
DE
BÛCHES
À
GAZ
SANS
CONDUIT
D’É
VACU
ATION À
L’INTÉRIEUR DE CE FOYER.
•
ALIMEN
TA
TION ÉLECTRIQUE: 120
V, 60 Hz
•
TYPE
DE
CHEMINÉE:
UTILISER
SEULEMENT
A
VEC
6
PO.
DIAMÈTRE
-
ÉT
ATS-UNIS:
IHP
SNAP-
PAK;
CAN:
SECURE
TEMP
ASHT
+
OU
S2100
+,
DUR
ATECH
CANADA
OU
DUR
ATECH PREMIUM.
•
PEUT
Ê
TRE
R
ACC
ORDÉ
S
UR
UN
E
CHEMIN
ÉE
D
E
M
AÇ
ON
N
ER
IE
TE
L
Q
U
E
D
ÉC
R
IT
D
AN
S
LE
M
ANU
EL
D’INS
TALL
ATION.
•
LE
S
CO
M
PO
SA
NT
ES
UT
IL
IS
ÉE
S
AV
EC
LE
F
OY
ER
D
OI
VE
NT
ÊTRE
HOMOLOGUÉES.
VOIR
LA
LISTE
DANS
LE
MANUEL
D’INS
TALL
ATION.
•
REMPLACER
LA
VITRE
A
VEC
UN
VERRE
CÉRAMIQUE
DE
5mm D’É
PAISSEUR.
•
PO
UR
U
N
E
UT
ILIS
ATIO
N
SÉ
CURI
TA
IRE,
I
NS
TALLE
R
CONFORMÉMENT AUX DIRECTIVES DU
FABRICAN
T.
•
ATTENTION
:
NE
P
AS
OBSTRUER
LES
ARRIVÉES
D’AIR
COMBURAN
T.
•
NE
PAS
FAIRE SURCHAUFFER LE FOYER.
•
LA
PO
RTE
DU
FOYER
DOIT
DEMEURER
TO
TALEMENT
FERMÉE LORSQUE LE FOYER FONCTIONNE.
•
NE
P
AS
UT
IL
IS
ER
DE
P
OÊLE
EN
CA
STR
AB
LE
OU
D
’A
UTRE
S
PR
OD
UIT
S
NO
N
SPÉ
CIF
IÉS
C
OM
M
E
ÉT
AN
T
UT
IL
ISABL
ES
AVEC CE PRODUI
T.
•
CON
TACTEZ
LES
RESPONSABLES
DE
VOTRE
REGION
A
PR
OP
O
S
DE
S
RE
STR
IC
TIO
N
S
ET
I
NSP
EC
TI
O
N
S
D’INS
TALL
ATION.
•
MAINTENIR
LES
MEUBLES
ET
AUTRES
OBJETS
À
UNE
DIS
TANCE SÉCURI
TAIRE DU FOYER.
•
CET
AP
PAREIL
DE
CHAUF
FAGE
AU
BOIS
DOIT
ÊTRE
INSPECTE
ET
ENTRETENU
PÉRIODIQUEMENT
POUR
FONCTIONNER
CORRECTEMEN
T.
VOIR
LE
MANUEL
DU
PRO
PR
IÉ
TA
IRE
POUR
PL
U
S
D
’IN
FOR
M
AT
ION
.
L’UTILIS
ATION
DE
CET
AP
PAREIL
DE
CHAUF
FAGE
AU
BO
IS
DE
M
ANI
ÈR
E
IN
CO
M
PA
TIB
LE
A
VE
C
LE
S
INS
TRU
C-
TI
ON
S
DU
M
ANU
EL
DU
P
RO
PRI
ÉT
AI
RE
C
ONS
TITU
E U
NE
INFRACTION AUX RÉGUL
ATIONS FÉDÉRALES.
FIREPLACE, ALSO FOR USE IN MANU
FACTURED
HOMES WITH SOLID FUEL ON
LY
CE FOYER EST ÉGALEMENT CE
RTIFIÉ POUR
INS
TALL
ATION DANS LES MAISONS MOBILES.
COMBUSTIBLES SOLIDES SEULEMEN
T.
Conforms to / Conforme au : UL STD 127
Certified to / Certifié au : ULC STD S610
C
US
Report No. / Rapport nº
14-199 R1
U.S. ENVIRONMEN
TA
L PROTECTION
AGENCY
EP
A certification test emission value 1.9 g/hr per 2020 NSPS (cordwood)
Valeur d’émission du test d’homologation 1,9 g/h selon la norme 2020 NSPS
Date of Manufacture / Date De Fabrication
202
1
202
2
202
3
J
AN
FE
B
M
AR
AP
R
M
AY
J
UN
J
UL
AU
G
SE
P
O
CT
NO
V
DE
C
JAN
V
FEV
R
M
AR
S
AV
R
M
AI
J
UI
N
J
UI
L
A
OÛ
T
SEP
T
O
CT
NO
V
DE
C
HEA
RTH EXTENSION M
ATERIAL:
M
INI
M
UM
1/
2” T
HIC
KNES
S NON
-CO
M
BUST
IBLE
.
MINIMUM CLEARANCES TO FINISHED FRAMED OPENING, IN INCHES
NOTE: Dimensions are to the standoffs
MINIMUM FLOOR PROTECTION FROM OPENING
CENTERED ON FIREPLACE, IN INCHES
INS
TALL WITH MINIMUM CLEARANCES TO
W
ALL
AS SHOWN IN INCHES.
SIDE
W
ALL - BACK
W
ALL
INS
TALL
ATION
0”
0”
FIREPLACE
FRONT
CORNER INS
TALL
ATION
0”
0”
FIREPLACE
FRONT
FLOOR PROTECTOR MINIMUM DIS
TANCE
FROM OPENING IN INCHES
HEA
RTH EXTENSION M
ATERIAL :
-
3/8 “ THICKNESS NON COMBUSTIBLE
M
ATERIAL
-
OR EQUI
VALENT
FIREPLACE
FRONT
18”
36”
•
USE WOOD FUEL ON
LY
•
A
N
ON-
COM
BU
STI
BL
E
H
EA
RT
H
EX
TEN
SI
O
N
M
US
T
BE
IN
ST
ALL
ED
AT
FRONT
OF
UNIT
EXTENDING
18
IN.
(457
MM)
A
T
FRONT
AND
39” (991 MM) WIDE MINIMUM.
•
ANY
M
ANT
EL
MU
ST
B
E N
ON-
CO
MB
US
TI
BL
E
•
W
AR
NING
: TH
IS
FIREPLACE
HAS
NOT
BEEN
TESTED
WITH
UN
-
VENTED
GAS
LOG
SE
T.
TO
REDUCE
RISK
OF
FIRE
OR
INJU
RY
DO
NO
T
IN
ST
ALL
A
N
U
N
VE
N
TED
GA
S
LOG
SE
T
IN
TO
T
H
E
FIR
EP
LA
CE
.
•
ELECTRICAL R
ATING: 120
V, 60 Hz
•
CHIMNEY TYPE: USE ON
LY WITH 6 IN. DIAMETER -
USA:
IHP
SNAP-
PAK;
CAN:
SECURE
TEMP
ASHT+
OR
S2100+,
DUR
ATECH CANADA OR DUR
ATECH PREMIUM.
•
CAN
BE
CONNECTED
TO
A
MASON
RY
CHIMNEY
AS
DESCRIBED
IN THE INS
TALL
ATION INSTRUCTIONS.
•
COM
PONEN
TS
US
ED
W
ITH
THE
FIR
EP
LAC
E
MUS
T
BE
L
ISTED
. S
EE
LI
ST
IN
TH
E IN
ST
ALL
AT
ION IN
STRUCT
IONS
.
•
REPLACE GLASS WITH CERAMIC GLASS 5 mm THICK.
•
FOR
SAFE
OPER
ATION
INS
TALL
IN
ACCORDANCE
WITH
THE
MANU
FACTURER’S INSTRUCTIONS.
•
CAU
TION
:
COM
BU
STION
A
IR
OPEN
ING
M
US
T
N
O
T
BE
O
B-
STRUCTED.
•
DO NOT OVERFIRE THE FIREPLACE.
•
OPER
ATE THE FIREPLACE WITH DOOR FUL
LY CLOSED ON
LY
.
•
DO
NO
T
US
E
A
FIR
EPL
ACE
IN
SE
RT
OR
OTH
ER
P
RODU
CTS
NO
T
SPE
CI
FI
ED FOR
U
SE
W
IT
H THI
S
PRODUC
T.
•
CON
TACT
YOUR
LOCAL
BUILDING
OR
FIRE
OFFICIALS
ABOUT
RESTRICTIONS
AND
INS
TALL
ATION
INSPECTIONS
IN
YOUR
AREA.
•
SEE
IHP
INS
TALL
ATION
AND
OPER
ATING
INSTRUCTIONS
FOR
THIS MODEL.
•
KEEP
FURNISHINGS
AND
OTHER
COMBUSTIBLE
M
ATERIALS
A
CONSIDERABLE DIS
TANCE
AW
AY FROM APPLIANCE.
•
TH
IS
W
OOD
H
EA
TE
R
N
EE
D
S
PE
R
IOD
IC
I
NS
PECT
ION
A
N
D
RE
PAIR
FOR
PROPER
OPER
ATION.
CONSU
LT
THE
OWNER’S
M
ANUA
L FOR
FU
RTH
ER
IN
FOR
M
AT
IO
N.
IT
IS
A
GA
INS
T F
EDE
RA
L
REGUL
ATIONS
TO
OPER
ATE
THIS
WOOD
HE
ATER
IN
A
MANNER
INCONSISTENT
WITH
THE
OPER
ATING
INSTRUCTIONS
IN
THE
OWNER’S MANUAL.
•
INS
TALL
AND
USE
ON
LY
IN
ACCORDANCE
WITH
THE
MANU
-
FACTURER’S INSTRUCTIONS AND LOCAL BUILDING CODES.
•
SP
ECI
AL
M
ETH
OD
S
ARE
REQ
UI
RED
W
HEN
P
AS
SI
NG
TH
ROU
GH
A
W
ALL
OR
CEILING.
SEE
INSTRUCTIONS
AND
BUILDING
CODES.
•
PREVENT
CREOSOTE
FIRE:
INSPECT
CHIMNEY
CONNECTOR
AND CHIMNEY FLUE MONTH
LY AND CLEAN IF NECESSA
RY
.
•
DO
NOT
OVERFIRE.
IF
DOME
OR
CHIMNEY
CONNECTOR
GLOWS
YOU ARE OVERFIRING.
INS
TALL WITH MINIMUM CLEARANCES TO
W
ALL
AS SHOWN IN INCHES.
SIDE
W
ALL - BACK
W
ALL
INS
TALL
ATION
0”
0”
FIREPLACE
FRONT
CORNER INS
TALL
ATION
0”
0”
FIREPLACE
FRONT
FLOOR PROTECTOR MINIMUM DIS
TANCE
FROM OPENING IN INCHES
HEA
RTH EXTENSION M
ATERIAL :
-
3/8 “ THICKNESS NON COMBUSTIBLE
M
ATERIAL
-
OR EQUI
VALENT
FIREPLACE
FRONT
18”
36”
39”
29