background image

TABLE OF CONTENTS

Safety Rules and Specifications for 

  Mobile or Manufactured 

  Home Installation .........................Page 2

Introduction ......................................Page 3

Parts Required  .................................Page 3

Optional Equipment ...........................Page 3

Operating The WCT6820WS 

  Fireplace ..........................................Page 3

Fuel ...................................................Page 3

Starting And Maintaining A Fire ........Page 4

Combustion Control  .........................Page 4

Refueling For Best Performance .......Page 4

Smoking – Causes And 

  Troubleshooting ..............................Page 4

Important Cautions ...........................Page 5

Maintaining Your Fireplace ................Page 5

Creosote ............................................Page 5

Chimney Maintenance .......................Page 5

Dealing With A Chimney Fire .............Page 5

Finish Door Casing Care ....................Page 7

Disposing of Ashes ...........................Page 7

Refractory Installation .......................Page 7

Door Installation ...............................Page 7

Door Adjustment ...............................Page 7

Facade Installation ............................Page 8

Hearth Extension Requirements ........Page 8

Cold Climate Installations ..................Page 8

Framing Dimensions .........................Page 9

Nailing Flanges ..................................Page 10

Facing And Mantel ............................Page 10

Fireplace Blower ................................Page 11

Hot Air Ducting Installation  ..............Page 11

Gravity Kit .........................................Page 11

Outside Air Kit  ..................................Page 12

Chimney System ...............................Page 13

Chimney Installation Notes ...............Page 13

Chimney Installation Instructions ......Page 14

Offset Chimney Installation ...............Page 15

Angled Wall Radiation Shield ............Page 17

Glass Care - Replacement .................Page 18

Glass Care - Cleaning ........................Page 18

Gasket Replacement  ........................Page 18

Fireplace Installation  ........................Page 18

Chimney Support Installation ............Page 19

Chimney Chase And 

  Multiple Terminations......................Page 19

Masonry Application Instructions .....Page 20

Installation Accessories ....................Page 21

Replacement Parts ............................Page 22

Specifications ....................................Page 22

Clearances to Combustibles ..............Page 22

Chimney Components Lists ..............Page 23

Warranty  ..........................................Page 25

Product Reference Information .........Page 26

THE FIREPLACE

INTRODUCTION

The  WCT6820WS wood-burning fireplace is 

an energy efficient, heat circulating, closed 

combustion fireplace.  You will receive a lifetime 

of comfort and enjoyment from your fireplace 

provided it is installed, maintained and oper-

ated properly.

• 

Please read these instructions and retain 

this manual for future reference.

• 

Before beginning the fireplace installation, 

consult the local authorities to obtain your 

building permit and check your local building 

codes.  Install the fireplace only as described 

in these instructions and using only IHP 

components.

•  This fireplace has been tested for CAN/ULC 

S610-M87 and ANSI/UL 127 under report 

number 307-4084.  It has also been tested 

for EPA 40 C.F.R Part 60, section 60.532(b).  

Certificate number 537.

• 

The WCT6820WS fireplace is NOT intended 

for use with a gas log set. Do not  use a 

fireplace insert or any other product with 

this fireplace unless it is specified by IHP 

for use with this appliance.  Failure to follow 

these instructions will void the certification 

and the warranty of the fireplace and may 

result in an unsafe installation. 

•  These appliances are designed to provide 

supplemental heat to the immediate area 

only. Therefore, it is advisable to have an 

alternate heat source when installed in a 

dwelling. 

PARTS REqUIRED

Fireplace Model WCT6820WS

•   6”  diameter  chimney 

*

 

- Model ASHT+, 

S-2100+, , or AC 

manufactured by Security Chimneys Inter-

national™ only, including:

  -  Chimney lengths

  - Elbows 

(where necessary)

  -  Associated components as per these 

    installation instructions

 ..

Decorative Door 

- Required 

....

(Order Separately - See

 Page 21)

  Front Facade kit - Required

...

(Order Separately - See

 Page 21)

  UZY5 blower

 (included in the fireplace).

  VRUW Blower Speed Control 

(included)

 

 

Outside air kit  

(Included w/Fireplace)

OPTIONAL EqUIPMENT

•   Additional Equipment (optional)

  - Forced Air Kit 

u

  - AC Chimney Adaptor 

*

  - AC Chimney Outside Air Kit

CONGRATULATIONS!

When you purchased your new fireplace, you joined the ranks of thousands of individuals 

whose answer to their home heating needs reflects their concern for aesthetics, efficiency 

and our environment. We extend our continued support to help you achieve the maximum 

benefit and enjoyment available from your new fireplace.

Thank you for selecting a IHP fireplace as the answer to your home supplemental heat-

ing needs.

  - Gravity Venting System

  - Rigid Firescreen 

u

Not tested under EPA certification. If 

installed, this appliance no longer quali-

fies for EPA certification. Check with local 

authorities having jurisdiction for require-
ments in your area.

OPERATING THE FIREPLACE

Fuel - 

USE SOLID NATURAL WOOD FUEL 

ONLY. This appliance is designed to burn dry 

seasoned natural wood only (see Page 6 for a 

list of prohibited fuels). Failure to burn proper 

fuels only will void the certification and the 

warranty of the appliance. 

Hardwoods are pre-

ferred to softwoods since the energy content of 

wood is relative to its density.  Hardwoods will 

result in a longer burning fire and less frequent 

refueling.  A moisture content of 15% to 20% 

(seasoned) is recommended.  Wood that has 

been cut and split and let to dry under a cover 

for a period of one year will usually meet that 

criteria.  The required drying time will vary 

depending on the climate. Wood that is packed 

tight together will take longer to dry. Seasoned 

wood is darker in color than wet wood and will 

have visible cracks in the grain on the ends.  

Excessively wet wood will be difficult to burn 

and will result in lower efficiency, increased 

creosoting and deposits on the glass and in 

the chimney.  Excessively dry wood will burn 

well but will also have higher emissions and 

shorter burning time.

DO NOT OVERFIRE THIS HEATER

Attempts to achieve heat output rates that 

exceed heater design specifications can result 

in permanent damage to the heater.

First Fires

Before using the fireplace make sure to remove 

the plastic wrapping and EPA label on plated 

door. Remove any glue residue left by the 

label using mild soap.

The first five or six fires should be small fires of 

short duration (about 30 to 60 minutes).  This 

will help cure the refractory bricks. During the 

first few fires of this appliance there may be 

some odor and smoke due to the curing of the 

paint, dust accumulation and burning off of 

lubricants used in the manufacturing process.  

It may set off a smoke alarm located in the same 

room.  For this reason the room should be well 

ventilated for the first few fires.

*

Available from Security Chimneys™ 

3

Содержание WCT6820

Страница 1: ...of glass doors Install this fireplace in a square and plumb condition using shims as necessary at sides and or bottom Install the fireplace only as described in these instructions This installation ma...

Страница 2: ...s ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free opera...

Страница 3: ...del ASHT S 2100 HT6000 HT6103 or AC manufactured by Security Chimneys Inter national only including Chimney lengths Elbows where necessary Associated components as per these installation instructions...

Страница 4: ...ing 10 to 20 minutes after reloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost can be closed and the primary air set to a medi...

Страница 5: ...e Monitor Recommended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fresh air immediately Somepeo...

Страница 6: ...o 11 20 NOTE The use of a firewood moisture meter is rec ommended to ensure the firewood contains less than 20 moisture Seasoning Guide Softwoods 6 months to 18 months Hardwoods 12 months to 24 months...

Страница 7: ...supplied will be necessary for this adjustment Checking Door Seal A one inch strip of paper may be used to perform a test of the integrity of the door seal Close the door on the paper in at least eigh...

Страница 8: ...cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with a non combustible ma terial tile marble stone etc See Figure 7 Cold climate INSTALLATIONS...

Страница 9: ...nstallation instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without notice Allframingdimensionscalculatedfor 1 2 dry wall at...

Страница 10: ...tside Walls Of Chase Solid Continuous Surface Outside Base Insulation Thermal Barrier 8 Level 7 2 1 m Min 6 8 2 m Min 8 2 4 m Level 42 1067mm 2 x 3 Min 51mm x 76mm Rock Board or Other Noncombustible F...

Страница 11: ...replace Blower The fireplace comes equipped with a heat acti vated blower It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circui...

Страница 12: ...diameter flexible pipe for the complete run up to thirty 30 feet and a 6 diameter pipe for a run of up to forty 40 feet The duct system must be installed respecting the following 1 Removetheplatesclo...

Страница 13: ...11 When offsets are used the pipe may not penetrate a ceiling or floor unless it is running vertical no 30 offsets Outside Intake Screw Opening Facing Down Wall Aluminum Tape Plastic Cover Insulation...

Страница 14: ...ofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using roofing nails 6 Place the spacers and the storm collar over the flashing and tighte...

Страница 15: ...a plumb bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below...

Страница 16: ...22 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 243...

Страница 17: ...bustible wall with the chimney at a 30 or 45 angle an angled firestop or wall radiation shield must be installed Only one is required NOTE 45 angle for Canada only RSMI45 In cold climate locations cli...

Страница 18: ...are maintained at hot temperatures see Refueling For Best Performance To clean the glass there are a numberofspeciallydesignedcleaners YourIHP dealercanrecommendasuitablecleanerwhich is available in y...

Страница 19: ...ns provided with the support CHIMNEY MODEL MAXIMUM HEIGHT OF SUPPORTED CHIMNEY Offset Support Roof Support ASHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m S 2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6...

Страница 20: ...cation Temporarily install the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval d...

Страница 21: ...bow 90 8 dia 7B26ZE90 H8948 Elbow 45 8 dia 7B26ZE45 H8949 Telescopic length 8 dia 15 to 26 7B26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1...

Страница 22: ...R2324 Log retainer bar PR SR2323 Door rod and lock PR SR2118 Steel door glass gasket PR SR1685D Cast iron door glass gasket PR SR1823H Steel and cast Iron door gasket PR SR1823G Touch up Paint Aerosol...

Страница 23: ...ess Steel Chimney 6 I D and 8 O D Double Wall Stainl Steel Listed to CAN UCL S604 and UL 103HT Description Part Cat No Lengths and Misc Chimney Components 8 length 6 Dia 6L8 6L8 12 length 6 Dia 6L12 6...

Страница 24: ...8 Length 6 Dia 6LL48 6LL48 Adjustable Length 7 to 11 6 Dia 6L7A 6L7A Split Base Tee 6 Dia 6LT 6LT Tee Cap 6 Dia 6TCS 6TCS Twist Lock Tee Cap 6 Dia 6LTC 6LTC Elbow 30 6 Dia 6LE30 6LE30 Elbow 45 6 Dia 6...

Страница 25: ...ormal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning...

Страница 26: ...ct your IHP dealer for any questions or concerns Replacement parts See Page 22 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered...