background image

www.SuperiorFireplaces.US.com

127035-01A

17

Figure 28 - Ignitor 

IGNITOR ASSEMBLY

The ignitor assembly is factory preset for 

proper ignition of the burner. Alterations may 

have occurred during shipping and handling. 

Call a qualified service person to readjust the 

ignitor assembly if necessary.
The ignitor should be positioned as shown 

in Figure 28.

Note: Figure 28, shows the correct positioning 

of the ignitor and sensing rod.
If your ignitor assembly does not meet these 

requirements:
•  turn appliance off (see 

To Turn Off Gas to 

Appliance

, page 17).

•  see 

Troubleshooting

, page 18

INSTALLATION

Continued

OPERATION

FOR YOUR SAFETY 

READ BEFORE LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, 

a  fire  or  explosion  may  result 

causing property damage, per

-

sonal injury or loss of life.

A.  This appliance does not have a pilot, 

it is equipped with an ignition device 

which automatically lights the pilot. Do 

not light pilot by hand.

B.  BEFORE  LIGHTING  smell  all  around 

the appliance area for gas. Be sure to 

smell next to the floor because some 

gas is heavier than air and will settle 

on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Do not use this appliance if any part has 

been under water. Immediately call a 

qualified service technician to inspect 

the appliance and to replace any part of 

the control system and any gas control 

which has been under water.

Ignitor

Ground 

Electrode

0.8000

Sensing 

Rod

Spark 

Gap 

0.120

Note:

 Reference only, not to scale

Содержание VRE4543E

Страница 1: ...mation in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death AVERTISSEMENT Assurez vous de bien suivre les instructions donn es...

Страница 2: ...he vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgas...

Страница 3: ...njury or death from burns fire explo sion electricalshockandcarbon monoxide poisoning DANGER Carbonmonoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poisoni...

Страница 4: ...or s phone Follow the gas sup plier s instructions if you cannot reach your gas supplier call the fire department SAFETY Continued 4 This fireplace shall be used only outdoors in a well ventilated spa...

Страница 5: ...l gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Vent free gas products are prohibited for bedroom and bathroom installation in the Comm...

Страница 6: ...rances from floor ceiling and adjoining wall Carefully follow the instructions below This will ensure safe installation CLEARANCES Minimum clearances to combustibles for the fireplace are as follows B...

Страница 7: ...Depth Ref Mantel from Top of Opening 1 12 A 24 2 9 B 21 3 6 C 18 4 4 D 16 5 2 E 14 A B C D E 1 2 3 4 5 Wall Supplied firebox hood must be used at all times Note All vertical measurements are from top...

Страница 8: ...8 INSTALLATION Continued 11 13 16 16 1 2 17 1 2 5 8 29 13 16 8 1 4 1 55 1 16 52 47 44 1 16 29 25 32 7 1 32 16 9 32 2 716 1 816 8 255 13 217 1 816 3 208 Figure 6 V LVFO43E Series Dimensions Gas Line A...

Страница 9: ...ry connec tions 3 Slide all wiring connections in electrical housing as shown in Figure 7 4 Secure electrical cover plate with screws previously removed Note Electrical housing and cover plate have sh...

Страница 10: ...your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace If pipe is too small undue loss of volume will occur Installation must include an equipment shutoff valve u...

Страница 11: ...of fireplace 2 Attach flexible gas line from gas supply to control valve see Figure 10 3 Check all gas connections for leaks See Checking Gas Connections CHECKING GAS CONNECTIONS WARNING Test all gas...

Страница 12: ...propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter to equip ment shutoff valve for natural gas or propane L...

Страница 13: ...el as a guide screw the rear panel to the fireplace as shown in Figure 14 INSTALLING HOOD 1 Loosen screws at top of face opening and slide hood through screws as shown in Figure 15 2 Tighten screws se...

Страница 14: ...ner Figure 20 Installing Access Door Retaining Brackets for See Thru Applications Retaining Bracket Figure 21 Installing Side Face Filler for See Thru Applications Removing Rear Interior Wall 1 Throug...

Страница 15: ...ating Control Module 1 Remove Access Plate See Figure 22 2 Remove 2 screws on top of the electronic access cover See Figure 23 3 Remove electronic access cover by gently pulling up and out of the fire...

Страница 16: ...located on the right side of the module that reads RE MOTE OFF Figure 26 2 When the remote off switch is in the OFF position the burner will operate from the rocker switch or wall switch connected to...

Страница 17: ...r sonal injury or loss of life A This appliance does not have a pilot it is equipped with an ignition device which automatically lights the pilot Do not light pilot by hand B BEFORE LIGHTING smell all...

Страница 18: ...the ON position Do not force 8 Replace access cover 9 Turn on all electric power to appliance 10 Turn safety shutoff switch to the ON position 11 Visually locate ignitor Ignitor should begin to spark...

Страница 19: ...y by a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater tha...

Страница 20: ...ticles enter the fireplace and burn causing brief patches of orange flame Burner flames will be steady not lifting or floating Flame patterns will be different from unit to unit and will vary dependin...

Страница 21: ...ge Orange Red Brown Black Solenoid White Brown Brown Green Ignitor Pilot I S AUX AF 5000MOD AF 4000 AF 4000B P Control Module Black Black SWI SWI GND Red HI LO Main Black BATTERY PACK Black Red Black...

Страница 22: ...closed 2 Air in gas lines when in stalled 3 Depleted gas supply pro pane LP only 4 Control module not in RE MOTE position 5 Gas control valve pressure setting is not correct 6 Inlet gas pressure is to...

Страница 23: ...ignitor assembly is relighting the burner 4 Wire connection loose or wire broken REMEDY 1 Contact local natural or propane LP gas company 2 Clean burner see Cleaning and Maintenance page 18 or replace...

Страница 24: ...every one second Gas odor during combustion POSSIBLE CAUSE 1 Appliance burning vapors from paint hair spray glues cleaners chemicals new car pet etc See IMPORTANT statement above 2 Low fuel supply pro...

Страница 25: ...www SuperiorFireplaces US com 127035 01A 25 PARTS MODELS VRE4543EN AND VRE4543EP 1 2 4 4 4 4 5 8 6 7 3 9 10 11 19 20 21 12 12 13 14 4 22 15 16 18 17...

Страница 26: ...mmet SC 1 2 ID 1 1 16 OD 1 8 116573 01 Flat Washer 7 9 11214 Bulkhead Fitting 1 10 14399 Brass Elbow 2 11 111817 01 Flextube 1 12 125932 01 Burner Gasket 2 13 126050 02 Electronic Access Cover LVFO 1...

Страница 27: ...Corner Bracket Stainless 4 10 125766 02 Side Walls 2 11 125761 02 Rear Wall LVFO 1 12 125768 02 Access Door Stainless 1 13 125766 02 Side Face Filler Stainless 2 14 125975 02 Fireplace Hood Stainless...

Страница 28: ...lfunctioning purchase date Usually we will ask you to return the part to the factory SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burner will have delayed ignition fireplace will...

Страница 29: ...al or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c dam...

Страница 30: ...NOTES...

Страница 31: ...IS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ________________...

Страница 32: ...127035 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P127035 01...

Отзывы: