SuperiorFireplaces.us.com
900991-00A
9
INSTALLATION
Continued
Opening
VRE4236
VRE4242
A
42-3/4" (1086)
48-3/4" (1238)
B
46-1/2" (1181)
46-1/2" (1181)
C
23-5/8" (600)
29-5/8" (753)
D
11-1/4" (286)
14-1/4" (362)
E
63-1/2" (1613)
69-1/2" (1765)
F
31-3/4" (807)
34-3/4" (883)
G
20-1/2"( 521)
20-1/2"( 521)
H
44-1/4" (1124)
49-1/8" (1248)
Table 1 - This Table Corresponds To Figure 6a, 6b and 6c
Figure
6a
Figure
A
FRAMING SPECIFICATIONS
Figure
6b
Figure
6c
Header
A
B*
* Increase Framing Height By 3/4”
When Using Optional Drain Pan
Corner Installation
A
C
D
H
F
G
E
Back Wall Of
Chase/Enclosure
Including Finishing
Materials If Any
Rough Framing Face
(Unfinished Shown)
C
G
A
Parallel Installation
Rough Framing Face
(Unfinished Shown)
Back Wall Of
Chase/Enclosure
Including Finished
Materials - If Any
*Increase Framing Height by 34" when using an Optional Drain Pan
inches (millimeters)
12
(305)
10
(254)
8
(203)
6
(152)
4
(102)
2
(51)
13 (330)
15 (381)
17 (432)
19 (483)
21 (534)
23 (585)
Fireplace
Mantel depth
WITHOUT
HOOD
INSTALLED
Top of Firebox
Opening
9 (229)
11 (280)
13 (330)
15 (381)
17 (432)
19 (483)
Hood
Fireplace
Mantel depth
WITH
HOOD
INSTALLED
12
(305)
10
(254)
8
(203)
6
(152)
4
(102)
2
(51)
Mantel Clearances