Operation
900004-00, 03/2018
Innovative Hearth Products
DRT2000 and DRC2000 Direct-Vent Fireplaces
59
Glass Media
Removing and cleaning the glass media
CAUTION
Risk of personal injury. Allow the media to completely cool before handling.
Use a clean, dry, empty shop vac to remove glass media. Wash the media in warm, soapy water. Rinse and dry
before reinstalling.
Reinstalling the glass media
Carefully follow the placement instructions (Page 51). This will ensure a proper flame and safe combustion.
NOTE: Improper positioning of media can create carbon build-up and will alter the performance of the fireplace.
Replacing the media
If the media needs replacement, use only the proper replacement media from manufacturer (Page 70).
Cleaning the burner
Carefully remove the logs/media. Vacuum out any foreign matter on the burner (e.g., lint, carbon, etc.). Ensure the
burner ports are free of debris.
NOTE: Improper positioning of logs/media can create carbon build-up and will alter the performance of the fireplace.
Inspecting the wiring
Refer to the wiring diagram (Figure 31 or 32).
CAUTION
When servicing controls, label all wires prior to disconnection. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
ATTENTION
Au moment de l’entretien des commandes, étiquetez tous les fils avant de les débrancher.
Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
Inspect and clean all wire connections. Ensure that there is no wire melting or damage. The inspection should
include:
• Terminals at the valve
• ON/OFF switch
• Optional wall thermostat, remote control, or wall switch