background image

Operation 

900004-00, 03/2018

Innovative Hearth Products
DRT2000 and DRC2000 Direct-Vent Fireplaces

48

OPERATION

 WARNING 

Young children should be carefully supervised when they are in the same room as the appliance. 

Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is 

recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install 

an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and 

away from hot surfaces.

 AVERTISSEMENT 

Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trouvent dans la même pièce que 

l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en 

contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes 

à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de 

sécurité; cette mesure empêchera les tout petits, les jeunes enfants et  toute autre personne à risque 

d’avoir accès à la pièce et aux surfaces chaudes.

 WARNING 

Reinstall any barrier removed before operating the fireplace. The barrier is designed to reduce the risk of 

burns from hot glass. Do not operate the fireplace without the barrier installed.

 WARNING 

Do not operate the fireplace if:
• The glass front is removed, cracked, or broken
• The surround trim assembly and screen are not installed

CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with 

headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas 

supply to the appliance and have it serviced by a qualified professional, as it may not be operating correctly. 

Some people are more affected by carbon monoxide than others, including pregnant women, people with heart 

or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

NOTE: Do not place furniture or other combustible materials within 36” of the front of viewing area(s).
NOTE: Children and adults should be alerted to the hazards of high surface temperature and should stay away to 

avoid burns or clothing ignition.

Remarqué : Les enfants et les adultes devraient être infor-més des dangers que posent les températures de 

surface élevées et se tenir à distance afin d’éviter des brûlures ou que leurs vêtements ne s’enflamment.

NOTE: Installation and repair should be done by a qualified service person. The fireplace should be inspected before 

use and at least annually by a professional service person. More frequent cleaning may be required due to excessive 

lint from carpeting, bedding material, etcetera. It is imperative that control compartments, burners and circulating air 

passageways of the fireplace be kept clean.

Remarqué : L’installation et la réparation devrait être confiées à un technicien qualifié. L’appareil devrait faire 

l’objet d’une inspection par un technicien professionnel avant d’être utilisé et au moins une fois l’an par la suite. 

Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une quantité 

importante de pous-sière. Il est essentiel que les compartiments abritant les commandes, les brûleurs et les 

conduits de circulation d’air de l’appareil soient tenus propres.

NOTE: Do not use these fireplaces if any part has been under water. Immediately call a qualified, professional service 

technician to inspect the fireplace and to replace any parts of the control system and any gas control which have 

been under water.

Remarqué : Ne pas utiliser cet appareil s’il a été plongé, même partiellement, dans l’eau. Appeler un technicien qualifié pour 

inspecter l’appareil et remplacer toute partie du système de commande et toute commande qui a été plongée dans l’eau.

Содержание DRC2000

Страница 1: ...fi ou par le fournisseur de gaz INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Installateur Laissez cette notice avec l appareil Consommateur Conservez...

Страница 2: ...VITRE EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas...

Страница 3: ...toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidri...

Страница 4: ...nds Mantels 15 Installation Preparation 15 Installation Installation Sequence 16 Construct the Fireplace Framing 16 Prepare the Fireplace Top Spacers 18 Route the Gas Supply Line to the Fireplace 18 V...

Страница 5: ...t subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou u...

Страница 6: ...Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning CARBON MONOXIDE POISONING Early signs of carbon monoxide poison...

Страница 7: ...combinations of fuels will degrade the performance of this system and may be dangerous Provide adequate clearances around air openings and adequate accessibility clearance for service and proper oper...

Страница 8: ...ace be kept clean Remarqu L installation et la r paration devrait tre confi es un technicien qualifi L appareil devrait faire l objet d une inspection par un technicien professionnel avant d tre utili...

Страница 9: ...3 23 kPa Table 3 Inlet Gas Supply Pressure Fuel Pressure Natural Gas 3 5 WC 0 87 kPa Propane 10 0 WC 2 49 kPa Table 4 Manifold Gas Supply Pressure Test gauge connections are provided on the front of...

Страница 10: ...es and Regulations 248 C M R Sections 4 00 through 8 00 Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts The flexible gas line connector us...

Страница 11: ...ning ducting These direct vent fireplaces are uniquely suited for installations requiring a utility shelf positioned directly above the fireplace Utility shelves like these are commonly used for locat...

Страница 12: ...H minimum height from roof to lowest discharge opening of vent Horizontal overhang Vertical wall Vent termination Storm collar Concentric vent pipe Flashing 1 25 4 mm minimum clearance to combustibles...

Страница 13: ...ce to nonmechanical air supply inlet to building or the combustion air inlet to any other fireplace 6 150 mm for fireplaces 10 000 Btu h 3 kW 9 230 mm for fireplaces 10 000 Btu h 3 kW and 50 000 Btu h...

Страница 14: ...ng the full width and depth of the unit The fireplace may be located on or near conventional construction materials However if installed on combustible materials such as carpeting vinyl tile or other...

Страница 15: ...8 203 6 152 4 102 2 51 in mm 8 203 10 254 12 305 14 356 16 406 18 457 Hood Fireplace Mantel depth Wall Finishes Surrounds Mantels NOTE Combustible wall finish materials and or surround materials must...

Страница 16: ...Verify Proper Fireplace Operation Page 40 Finishing 14 Optional Install the Firebox Liners Page 41 15 Traditional Fireplaces Install the Logs Volcanic Stone and Glowing Embers Page 41 16 Contemporary...

Страница 17: ...rner Installation with Horizontal Termination Model A B C D E F G 33 Models 33 3 4 857 mm 51 1 4 1302 mm 36 1 4 921 mm 25 5 8 651 mm 12 1 8 308 mm 5 1 2 140 mm 14 1 2 368 mm 35 Models 35 3 8 899 mm 59...

Страница 18: ...ace framing Pipe coupling recommended 5 1 4 140 mm 3 77 mm Proper Sizing of Gas Line Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be inst...

Страница 19: ...Figure 33 5 Install the blower control switch according to its included instructions 6 Place the Fireplace in the Framing and Secure NOTE Nailing flanges combustible members and screw heads in areas...

Страница 20: ...r vertical Baffle from top retain screws but discard baffle Reinstall screws to seal holes after vertical baffle is removed Discard the vertical baffle Step 8 Remove the 2 screws holding the block off...

Страница 21: ...m horizontal run 60 ft Maximum vertical run 60 1 9 25 Horizontal Distance ft Vertical Height ft Vertical Height ft 2 5 Elbow 5 10 15 Base wing Base 6 ft Minimum vertical run 6 ft Minimum vertical run...

Страница 22: ...ed a 6 x 1 2 screw can be used at the joint but is not required as the pipe will securely lock when twisted Figure 17 Where required a telescopic vent section SV4 5LA may be used to provide the instal...

Страница 23: ...5 0 6 186 15 5 0 0 0 0 4 4 196 5 16 375 0 1 0 0 4 5 207 17 25 0 0 0 6 0 6 211 5 17 625 1 0 0 6 0 7 217 5 18 125 0 1 0 6 0 7 229 5 19 125 0 0 1 6 0 7 232 5 19 375 0 0 0 0 5 5 241 5 20 125 0 0 0 7 0 7 2...

Страница 24: ...d or adjacent walls is specified in ANSI Z223 1 In Canada the current CAN CGA B149 1 installation code by major building codes Always consult your local codes for specific requirements A general guide...

Страница 25: ...e 22 6 Install firestop spacer at ceiling When using Secure Vent use SV4 5VF firestop spacer at ceiling joists when using Secure Flex use SF4 5VF firestop spacer If there is living space above the cei...

Страница 26: ...at top and sides only and trim where necessary Seal the top and both sides of the flashing with waterproof caulking 12 Install the storm collar Install the storm collar supplied with the flashing ove...

Страница 27: ...ere an elbow is the only vertical component in the system WARNING Do NOT join separate sections of concentric flexible vent pipe Figure 25 Top Vent Straight Table 17 Rear Vent One 90 Elbow Ceiling fir...

Страница 28: ...un with more than 6 ft of vertical rise See Page 21 for more information If 25 ft of H horizontal vent run is needed then 5 ft straight section minimum of V vertical vent will be required This table s...

Страница 29: ...ain the minimum clearances for combustibles Page 24 2 Frame the exterior wall opening Locate the center of the vent outlet on the exterior wall Table 11 Cut and or frame an opening 10 1 2 x 12 1 8 267...

Страница 30: ...gure 27 13 Install the firestop spacer at the exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacer over the opening at the exterior side of t...

Страница 31: ...ent of Vent Run Sections Relative to Exterior Surface of Framing Last Vent Section Use Telescopic Vent Section SV4 5LA If Necessary Adaptor SV4 5RCH Use silicone caulking to seal the top and sides of...

Страница 32: ...near level Use a carpenter s level to measure from a constant surface and adjust the support straps as necessary NOTE SV4 5VF Secure Vent SF4 5VF Secure Flex firestop spacer must be used any time vent...

Страница 33: ...ge 21 for more information Compact termination SV4 5HTKCT shown See Table 21 as an aid in venting component selection for a particular range of exterior wall thicknesses If 25 ft of H horizontal vent...

Страница 34: ...cure Flex use ceiling firestop spacer SF4 5VF When using Secure Flex use wall firestop spacer SF4 5HF Wall firestop spacer SV4 5HF Ceiling firestop spacer SV4 5VF H V H1 H2 Table 28 Top Vent Three 90...

Страница 35: ...d the inner flexible vent then push it back out of the way b Apply a bead of Mill Pac Black 700 F high temperature sealant P N 10K81 to the inner adaptor collar approximately 1 2 from the end c Pull a...

Страница 36: ...Secure Flex vent to Secure Flex terminations only Do NOT substitute Secure Vent terminations or Secure Vent adaptor for Secure Flex components Secure Flex termination and adaptor collars are a differ...

Страница 37: ...DAPTOR HOT NEUTRAL OPTIONAL GROUND BATTERY HOLDER DFC WIRE HARNESS SPARK WIRE CABLE PILOT GROUND WIRE PILOT SENSOR CABLE HOOD IGNITER ROD FLAME SENSOR PILOT TUBE CPI SWITCH OFF O INTERMITTENT PILOT MO...

Страница 38: ...ction box 4 Connect the black power supply wire to the lower outlet s red pigtail lead Figure 33 Connect the white power supply wire to the outlet s common terminal 5 Connect the ground supply wire to...

Страница 39: ...it according to the installation instructions provided with the kit NOTE The tab connecting the receptacles of the outlet box must be broken in FBK 100 and FBK 200 blower kit applications Figure 33 12...

Страница 40: ...pen flame to check for leaks Turn on gas supply and test for gas leaks using a gas leak test solution also known as bubble leak solution NOTE Using a soapy water solution is an effective leak test sol...

Страница 41: ...due to sooting resulting from improperly setting the air shutter is not covered under the warranty The air shutter rod and nearby appliance surfaces are hot Exercise caution to avoid injury while adju...

Страница 42: ...f air shutter is open too far Flame will be blue Air shutter gap should be decreased Figure 38 Air Shutter Adjustment Rod Air Shutter Adjustment Rod Down Fully Open Position Burner Tube Adjustment Rod...

Страница 43: ...All models must have a barrier installed prior to operation 1 Open the control compartment door Page 50 2 Hold the barrier in front of the glass door and slide it up into the slots above the glass do...

Страница 44: ...ollez l tiquette sur la surface de la plaque de l interrupteur mural qui contr le le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parl e dans la r sidence...

Страница 45: ...ption The following flashing comes packaged with a storm collar 77L78 SV4 5F Flat Roof Flashing 77L79 SV4 5FA 1 12 to 7 12 Adjustable Flashing 77L80 SV4 5FB 7 12 to 12 12 Adjustable Flashing 77L81 SV4...

Страница 46: ...with 48 1219 mm compressed flex H1969 SF4 5HT 2 Horizontal Square Termination for flex without flex 77L87 SFKIT12S Square Term for flex with 12 305 mm compressed flex 77L88 SFKIT18S Square Term for f...

Страница 47: ...bon fonctionnement de l appareil converti n a pas t v rifi selon les instructions du fabricant fournies avec la trousse Le fournisseur de service qualifi ayant r alis l installation assume les respon...

Страница 48: ...ed by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes NOTE Do not place furniture or o...

Страница 49: ...ueelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontro...

Страница 50: ...off of the lubricants used in the manufacturing process Depending on usage the burn in period may take a few hours or a few days NOTE Ventilate the site during the burn in period The resulting odor a...

Страница 51: ...an electronic gas valve have a continuous pilot ignition CPI switch installed in the control compartment This switch allows the pilot to be switched from intermittent mode to continuous mode Intermit...

Страница 52: ...ding to these instructions improper combustion could occur This could result in the excessive production of soot and or the colorless odorless toxic gas carbon monoxide CO NOTE If applicable install t...

Страница 53: ...ilot flame is not obstructed See Verifying Appliance Operation on Page 39 1 If necessary remove the glass door Page 56 Locate and bend up Burner Locating Tabs Figure 47 2 Locate the log placement brac...

Страница 54: ...If necessary remove the glass door Page 55 2 Locate the log placement brackets not all are shown Figure 51 Figure 51 Placing log 1 Figure 52 Placing logs 2 and 3 Glowing Embers Do not place glowing em...

Страница 55: ...installed AVERTISSEMENT Une barri re con ue pour r duire le risque de br lure par le hublot chaude est fournie avec l appareil et doit tre install WARNING The door should easily close without needing...

Страница 56: ...nnel with the flat side toward the fireplace then swinging the base of the barrier into the brackets and lowering it into place 5 Close the control compartment door Removing the BARRIER 1 Open the acc...

Страница 57: ...components However more frequent periodic inspections and cleanings should be performed by the homeowner NOTE Prior to the first use of the fireplace and each burn season and periodically during the...

Страница 58: ...able at your local IHP dealer Never attempt to paint a hot fireplace Do not attempt to repaint the fireplace until the finish is completely cured Burn in Period on Page 50 If the surface becomes stain...

Страница 59: ...r Page 70 Cleaning the burner Carefully remove the logs media Vacuum out any foreign matter on the burner e g lint carbon etc Ensure the burner ports are free of debris NOTE Improper positioning of lo...

Страница 60: ...signs of dislocation of the vent components Fireplace Inspection Qualified Service Technician Perform the appropriate fireplace inspection procedure detailed in this manual Replacing Glowing Embers Ho...

Страница 61: ...ch 80L86 FBK 250 Blower Variable Speed with thermal snap switch Glowing Embers and Volcanic Stone Table 42 Glowing Embers and Volcanic Stone Catalog Model Description 88L53 FGE Bag of Glowing Embers 8...

Страница 62: ...S STAT Wall control Catalog Number Large LCD display Shows room and set temperatures in F and C Wall mounted Thermostatic or manual ON OFF operation Connects to wall switch wire H8864 Model WS S TSTA...

Страница 63: ...e Catalog Model 85L87 FWSK Table 48 OFF ON Wall Switch Kit Variable Speed Wall Switch Kit The variable speed wall switch kit provides variable speed control if the optional FBK 100 blower kit is insta...

Страница 64: ...mediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control knob to OFF and call y...

Страница 65: ...mm diatement un technicien qualifi ou le fournisseur de gaz Si la veilleuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et appelez un technicie...

Страница 66: ...gas control which has been under water Electronic Gas Control Valve SIT Electronic Pilot Assembly 3 Turn off all electric power to the appliance if service is to be performed Note The control may hav...

Страница 67: ...r peut avoir une batterie de secours installer les batteries au besoin 8 Placez l interrupteur du r cepteur en position REMOTE ou l interrupteur mural en position ON 9 Si applicable Appuyez sur le bou...

Страница 68: ...the lighting instructions a Defective pilot generator thermocouple Check pilot flame it must impinge on thermocouple Clean and or adjust pilot for maximum flame impingement on thermocouple Ensure that...

Страница 69: ...gas supply and gas shutoff valves b Loose wires to the valve or ignition module Check control compartment for any obviously loose wiring call a service technician if necessary c Pilot flame is not en...

Страница 70: ...L17 1 Millivolt Pilot Assembly Liquid Propane 69L18 1 69L18 1 69L18 1 69L18 1 Millivolt Piezo Igniter 10K86 1 10K86 1 10K86 1 10K86 1 Millivolt Piezo Igniter Wire 56L21 1 56L21 1 56L21 1 56L21 1 Milli...

Страница 71: ...ly approved with this appliance may result in property damage or personal injury Table 54 Homeowner Replacement Parts Description 33 Models 35 Models 40 Models 45 Models Catalog Number Qty Catalog Num...

Страница 72: ...Operation 900004 00 03 2018 Innovative Hearth Products DRT2000 and DRC2000 Direct Vent Fireplaces 72 Back view not representative of all fireplace models 6 3 2 8 4 1 7 5 Figure 48 Replacement Parts...

Страница 73: ..._______________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________________...

Страница 74: ...______________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________...

Страница 75: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 76: ...changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed i...

Отзывы: