background image

Superiorfireplaces.US.com

126745-01D

13

FIREPLACE INSTALLATION 

Continued

IHP recommends that a black iron gas line be routed from the gas 

source, through a sediment trap (shown in Figure 16), and into ap-

pliance. Once connected through appliance, a flexible gas line may 

be used for ease of installation to gas control valve (see Figure 17).

Before connecting the black iron gas line to the inside of the appliance 

a sediment trap must be included outside the appliance between the 

gas line and the gas shutoff valve. It must extend down 3" beyond 

the center of the pipe. Prepare incoming black iron gas line with 

Teflon tape or pipe joint compound (Check with local building codes).

 CAUTION: Compounds used on threaded joints of 

gas piping shall be resistant to the action of Liquefied 

Petroleum (LP or propane), and should be applied 

lightly to ensure excess sealant does not enter the 

gas line. Sealant should not be used on a flare fitting

 WARNING: All gas piping and connections must 

be tested for leaks after the installation is completed.
After ensuring that the gas valve is on, apply a non-

corrosive leak detection solution to all connections 

and joints. If bubbles appear, leaks can be detected 

and corrected.
Do not use an open flame for leak testing and do not 

operate any appliance if a leak is detected.

Complete your gas installation by connecting incoming gas line 

with flexible gas line. Secure tightly with wrench but 

DO NOT 

OVERTIGHTEN.

Figure 14 - Manual Shutoff Valve Installation

Figure 15 - Routing Incoming Gas Line

8

3

/

8

"

10

5

/

8

"

1/2" NPT Incoming
Black Iron Gas Line

Flexible 
Gas Line 
(1 Provided) 
Can Be 
Extended Out
Either Side

7"

7"

Alternate Gas Supply
Through Sub-Floor

Typical Exterior 

Wall Gas Shutoff 

Installation

Key

Extension

Shutoff Valve

Figure 16 - Sediment Trap

3" Min.

(7.6 cm)

Side W

all 

Of Appliance 

Incoming 

1/2" Gas Line 

Permitted by 

Local Codes

Sediment 

Trap (Not 

Supplied)

Figure 17 - Connecting Flexible Gas Line to Millivolt Valve

P

IL

O

T

ON

OFF

IN

OUT

Gas Shutoff 

Valve

Flexible Gas Line 

Do NOT Kink

1/2" NPT 

Incoming 

Gas Line

Note:

1) Wire Connections 

Not Shown for Clarity

2) * 1/8" NPT Plugged 

Tapping

Red Surface Indicates For 

Propane/LP Use Only

Pilot Adjustment

Inlet Pressure Tap

Outlet 

Pressure Tap

Содержание BRT2000 Series

Страница 1: ...e risque d incindie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other...

Страница 2: ...lation and operational procedures For assis tance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanent...

Страница 3: ...he fireplace in high traffic areas in windy or drafty areas 5 This fireplace reaches high temperatures Keep children and adults away from hot surfaces to avoid burns or clothing igni tion Fireplace wi...

Страница 4: ...an the type of gas approved for use in this gas appliance Installation must conform with local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 This fireplace...

Страница 5: ...PROPANE LP Max Input Rating 15 000 Btu Hr 25 000 Btu Hr Manifold Pressure 10 WC 2 49 kPa 10 WC 2 49 kPa Minimum Supply Pressure 11 WC 2 74 kPa 11 WC 2 74 kPa Maximum Supply Pressure 13 WC 3 23 kPa 13...

Страница 6: ...d or at a premium and since the space required to enclose the appliance would be located beyond an outside wall this would also reduce the cutting of joists roof rafters and such Check local codes for...

Страница 7: ...ling 0 Clearance Ceiling 1 2 5 cm Min Clearance to B Vent s Outer Pipe Required Air Spaces are Indicated with an Do Not Pack with Insulation or Any Other Material DO NOT BLOCK OR OBSTRUCT OPENINGS 0 C...

Страница 8: ...o cover any openings Prepare the incom ing gas line with Teflon tape or pipe joint compound and hookup incoming gas line to flexible gas line PRE INSTALLATION PREPARATION Continued Note If 1 2 NPT bla...

Страница 9: ...t above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT...

Страница 10: ...lateral length must exceed 75 then the system must be sized in accordance with the Category I venting tables Example 2 shows a multiple offset each at 45 of inclination Multiple offsets are permitted...

Страница 11: ...8 12 to 9 12 2 0 0 61 Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Ove...

Страница 12: ...e s gas sup ply system You may consider installing an extra gas shutoff valve outside the appliance s enclosure check with local codes where it can be accessed more conveniently with a key through a w...

Страница 13: ...nstallation is completed After ensuring that the gas valve is on apply a non corrosive leak detection solution to all connections and joints If bubbles appear leaks can be detected and corrected Do no...

Страница 14: ...under the lower grate members to allow air to flow see Figure 21 LOG PLACEMENT FOR BRT2032TMN MODEL 1 Place front log onto front of grate sliding log all the way forward against grate fingers see Fig...

Страница 15: ...ace top of log 4 into notch on log 1 Rest log 4 on the center of grate as shown in Figure 26 5 Place top of log 5 into notch on top right of log 1 see Figure 26 Rest log 5 between two middle grate fin...

Страница 16: ...ge of firebox opening 4 Tilt door assembly fully vertical until outer pivot pin snaps into mounting hole in upper spring clip see Figure 30 5 Once top and bottom pins are secured unfold door into clos...

Страница 17: ...ly Opened Door Figure 32 Removing Glass Doors Spring Clip Press Spring Clip to Release Pivot Pin Remove Bottom Pin From Pivot Plate While Sliding Door Out of the Upper Track Pivot Plate Fold Bi Fold D...

Страница 18: ...ndicator Gas Control Knob Pilot Adjustment Screw LIGHTING INSTRUCTIONS NOTICE During initial operation of new fireplace burning logs will give off a paper burning smell Orange flame will also be prese...

Страница 19: ...l knob to ON position Slide the selector switch to the REMOTE position Note Burner may light if hand held remote ON button was on when selector switch was last turned off You can now turn burner on an...

Страница 20: ...nce off see To Turn Off Gas to Appliance page 19 see Troubleshooting page 21 Figure 36 Typical Flame Pattern BRT2332TMN BRT2532TMN Models BRT2032TMN Model WARNING Installation and repair should be don...

Страница 21: ...ossible obstructions 4 Contact your gas supplier 5 Refer to section on pilot lighting 6 Have a qualified technician replace pilot line 7 Replace regulator valve see Accessories page 23 1 Check wiring...

Страница 22: ...tween control valve and burner 2 Gas leak See Warning statement at top of page 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked 4 Improper venting or excessive...

Страница 23: ...of your fireplace ready You can also visit our web site at IHP US com ACCESSORIES Purchase these accessories from your local dealer If they can not supply these accessories call IHP at 1 800 655 2008...

Страница 24: ...ces US com 126745 01D 24 PARTS MODEL BRT2032TMN 33 43 41 15 19 6 7 24 14 30 26 29 25 28 27 36 14 12 13 23 16 31 32 20 32 38 39 40 40 4 34 35 21 17 8 10 18 5 5 2 22 1 3 37 42 11 11 9 CATALOG NO MODEL F...

Страница 25: ...ebox Face 1 21 108412 01 Smoke Deflector 1 22 Fireplace Top Insulation 1 23 109797 01 Grate Assembly 1 24 109107 01 Burner Assembly see page 30 1 25 14512 Gas Control Valve Natural Gas 1 14513 Gas Con...

Страница 26: ...6 PARTS BRT2332TMN AND BRT2532TMN MODELS 33 43 41 15 19 6 7 24 14 30 26 29 25 28 27 18 14 12 13 23 10 36 9 36 35 16 31 32 20 32 38 39 40 40 4 34 21 17 8 46 45 44 2 22 1 3 44 11 37 42 5 5 CATALOG NO MO...

Страница 27: ...1 21 108412 01 Smoke Deflector 1 22 Fireplace Top Insulation 1 23 109040 01 Grate Assembly 1 24 108712 03 Burner Assembly see page 30 1 25 14512 Gas Control Valve Natural Gas 1 14513 Gas Control Valv...

Страница 28: ...2 PARTS BURNER ASSEMBLY This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Replacement Parts on page 23 of this manual KEY NO PART NO...

Страница 29: ...5 KEY NO PART NO DESCRIPTION QTY 109100 02 Log Set 1 109421 01 Rear Log 1 2 109420 01 Front Right Log 1 3 108723 01 Front Left Log 1 4 108722 01 Top Y Log 1 5 108720 01 Top Log 1 WIRING DIAGRAM DO NOT...

Страница 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 31: ...to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in...

Страница 32: ...Printed in U S A 2013 IHP LLC P N 126745 01 Rev D 10 2014 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 IHP US com KEEP THIS WARRANTY Model located on product or identification tag _...

Отзывы: