background image

SS2000MD4M-O 

 

Page 25

Содержание SLO-SYN SS2000MD4M-O

Страница 1: ...INSTALLATION INSTRUCTIONS for SLO SYN MODEL SS2000MD4M O MICROSTEP DRIVE OSCILLATOR...

Страница 2: ...ng refinements on all its products Such refinements may affect information given in instructions Therefore USE ONLY THE INSTRUCTIONS THAT ARE PACKED WITH THE PRODUCT RECORD OF REVISION Revision Date D...

Страница 3: ...4 1 Mechanical Specifications 11 4 2 Electrical Specifications 11 4 3 Environmental Specifications 11 4 4 Motor Compatibility 11 4 5 Switches and Potentiometers 13 4 5 1 Motor Current Settings 13 4 5...

Страница 4: ...4 2 Suggested Methods for Control Interface 16 4 3 Timing Considerations 17 Typical Torque Versus Speed Curves M061 LE08 Series and Parallel 19 M062 LE08 Series and Parallel M063 LE08 Series 20 M063 L...

Страница 5: ...re doing any me chanical work CAUTION The SLO SYN SS2000MD4M O is designed for 24 to 40 Vdc input only see Section 4 2 Electrical Specifications Page 11 WARRANTY INFORMATION Reconfiguration of the cir...

Страница 6: ...cillator fails to operate properly Appendix A provides procedures for troubleshooting electrical interference problems 1 2 PRODUCT FEATURES The SLO SYN SS2000MD4M O Drive Oscillator combines a bipolar...

Страница 7: ...ntain case temperature below 70 C 158 F 3 Select the desired motor current at standstill 50 or 100 and set switch 6 as described in section 4 5 2 4 Select the appropriate run speed source on board tri...

Страница 8: ...it in place Do not use too much thermal compound It is better to use too little than too much Figure 3 1 Mounting Diagram NOTE Case temperature must not exceed 70 C 158 F When selecting a mounting loc...

Страница 9: ...age 7 3 2 TERMINAL LOCATIONS AND ASSIGNMENTS Figure 3 2 shows the terminal locations for the SLO SYN SS2000MD4M O Drive Oscillator Figure 3 2 Terminal Locations Motor and Power Supply Connector J2 I O...

Страница 10: ...nd M5 The motor frame must be grounded Cabling from the Drive Oscillator to the motor should be done with a shielded twisted pair cable The wires for each motor phase should be twisted together about...

Страница 11: ...LEAD MOTORS D F B H 5 4 1 3 GREEN WHITE RED RED 6 LEAD MOTORS WHITE N C E 2 G N C BLACK WHITE GREEN D F B H 5 4 1 3 WHITE BLACK WHITE RED RED 8 LEAD MOTORS SERIES CONNECTIONS G BLACK A WHITE ORANGE E...

Страница 12: ...nt and voltage parameters see list of components below It is recommended that the power supply leads be twisted together using approximately six twists per foot 0 3 m NOTES 1 The cable between the fil...

Страница 13: ...ooling may be required Storage 40 F to 167 F 40 C to 75 C Humidity 95 max noncondensing Altitude 10 000 feet 3048 m max 4 4 MOTOR COMPATIBILITY Motor Types Superior Slo Syn M and KM Series M Series Fr...

Страница 14: ...0 KML060F08 3 5 1 0 2 0 KML060F11 3 5 1 0 2 0 KML061F05 2 5 1 2 1 5 KML061F11 3 5 1 0 3 0 KML062F07 3 0 1 0 2 5 KML062F13 3 5 1 0 4 0 KML063F07 3 0 1 5 2 0 KML063F13 3 5 1 0 4 0 KML091F07 3 0 1 0 2 0...

Страница 15: ...ll OFF 1 0 1 1 5 2 2 0 3 2 5 4 3 0 5 3 5 4 5 2 Automatic Current Reduce Disable When switch 6 is in the OFF position the current at standstill goes to 50 of the selected level When switch 6 is in the...

Страница 16: ...nverted to digital form using an 8 bit A D This will result in granularity in the resolution settings The ranges of each p a rameter are specified in Full Steps sec and Full steps sec2 Parameter Descr...

Страница 17: ...d set speed AWO All Windings Off Input J1 4 When this signal is low AC and DC current to the motor will be zero Caution There will be no holding torque when the AWO signal is low GND Signal ground J1...

Страница 18: ...he LOW SPEED input is active the motor speed will stay at Low speed otherwise the speed is increased to the Run speed at the acceleration rate set via the ACCEL potentiometer When the RUN input is rem...

Страница 19: ...epict the timing relationships between the RUN in put motor speed and motor current Figure 4 3 Timing Considerations 50 ms 50 ms Run Input Low Speed MOTOR SPEED Run Speed Current Motor Speed with LOW...

Страница 20: ...abilities which may cause a loss of torque at step ping rates outside the range of natural resonance frequencies One such instability is broadly defined as mid range instability Usually the damping of...

Страница 21: ...SS2000MD4M O Page 19 5 2 TYPICAL TORQUE VERSUS SPEED CURVES NOTE The test conditions used when obtaining the torque versus speed data are listed in the lower left hand corner of each curve...

Страница 22: ...Page 20 SS2000MD4M O...

Страница 23: ...SS2000MD4M O Page 21...

Страница 24: ...Page 22 SS2000MD4M O...

Страница 25: ...SS2000MD4M O Page 23...

Страница 26: ...Page 24 SS2000MD4M O...

Страница 27: ...SS2000MD4M O Page 25...

Страница 28: ...Page 26 SS2000MD4M O...

Страница 29: ...lowing checklist will help in locating and correcting the problem In General Check all installation wiring carefully for wiring errors or poor connections Check to see that the proper voltage levels a...

Страница 30: ...er supply voltage IF FAULT INDICATOR IS LIT Check For Improper motor wiring Grounded or shorted wiring to the motor or shorted motor Improper motor type or incorrect Current Select switch setting If a...

Страница 31: ...onditioning such as line filters or isolation transformers 2 Be certain proper wiring practices are followed for location groun ding wiring and relay suppression It is highly suggested that twisted pa...

Страница 32: ...Page 30 SS2000MD4M O Notes...

Страница 33: ...h or altered in any way which has been improperly installed or which has been subject to misuse neglect or accident THE FOREGOING WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDI...

Страница 34: ...nd application information or for the address of the closest authorized distributor IN U S A AND CANADA 383 Middle Street Bristol CT 06010 Tel 860 585 4500 FAX 860 589 2136 Customer Service 1 800 787...

Отзывы: