WARRANTY AND LIMITATION OF LIABILITY

Superior Electric (the "Company"), Bristol, Connecticut, warrants to the first end user pur-
chaser (the "purchaser") of equipment  manufactured by the Company that such equip-
ment, if new, unused and in original unopened cartons at the time of purchase, will be free
from defects in material and workmanship under normal use and service for a period of one
year from date of shipment from the Company's factory or a warehouse of the Company in
the event that the equipment is purchased from the Company or for a period of one year
from the date of shipment from the business establishment of an authorized distributor of
the Company in the event that the equipment is purchased from an authorized distributor.

THE COMPANY'S OBLIGATION UNDER THIS WARRANTY SHALL BE STRICTLY AND
EXCLUSIVELY LIMITED TO REPAIRING OR REPLACING, AT THE FACTORY OR A
SERVICE CENTER OF THE COMPANY, ANY SUCH EQUIPMENT OR PARTS
THEREOF WHICH AN AUTHORIZED REPRESENTATIVE OF THE COMPANY FINDS
TO BE DEFECTIVE IN MATERIAL OR WORKMANSHIP UNDER NORMAL USE AND
SERVICE WITHIN SUCH PERIOD OF ONE YEAR. THE COMPANY RESERVES THE
RIGHT TO SATISFY SUCH OBLIGATION IN FULL BY REFUNDING THE FULL PUR-
CHASE PRICE OF ANY SUCH DEFECTIVE EQUIPMENT

. This warranty does not apply

to any equipment which has been tampered with or altered in any way, which has been
improperly installed or which has been subject to misuse, neglect or accident.

THE FOREGOING WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE,

 and of any other

obligations or liabilities on the part of the Company; and no person is authorized to assume
for the Company any other liability with respect to equipment manufactured by the Com-
pany. The Company shall have no liability with respect to equipment not of its manufacture.

THE COMPANY SHALL HAVE NO LIABILITY WHATSOEVER IN ANY EVENT FOR
PAYMENT OF ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING,
WITHOUT LIMITATION, DAMAGES FOR INJURY TO ANY PERSON OR PROPERTY.

Written authorization to return any equipment or parts thereof must be obtained from the
Company. The Company shall not be responsible for any transportation charges.

IF FOR ANY REASON ANY OF THE FOREGOING PROVISIONS SHALL BE INEFFEC-
TIVE, THE COMPANY'S LIABILITY FOR DAMAGES ARISING OUT OF ITS MANUFAC-
TURE OR SALE OF EQUIPMENT, OR USE THEREOF, WHETHER SUCH LIABILITY IS
BASED ON WARRANTY, CONTRACT, NEGLIGENCE, STRICT LIABILITY IN TORT OR
OTHERWISE, SHALL NOT IN ANY EVENT EXCEED THE FULL PURCHASE PRICE OF
SUCH EQUIPMENT.

Any action against the Company based upon any liability or obligation arising hereunder or
under any law applicable to the sale of equipment, or the use thereof, must be commenced
within one year after the cause of such action arises.

Содержание SLO-SYN SS2000MD4M-O

Страница 1: ...INSTALLATION INSTRUCTIONS for SLO SYN MODEL SS2000MD4M O MICROSTEP DRIVE OSCILLATOR...

Страница 2: ...ng refinements on all its products Such refinements may affect information given in instructions Therefore USE ONLY THE INSTRUCTIONS THAT ARE PACKED WITH THE PRODUCT RECORD OF REVISION Revision Date D...

Страница 3: ...4 1 Mechanical Specifications 11 4 2 Electrical Specifications 11 4 3 Environmental Specifications 11 4 4 Motor Compatibility 11 4 5 Switches and Potentiometers 13 4 5 1 Motor Current Settings 13 4 5...

Страница 4: ...4 2 Suggested Methods for Control Interface 16 4 3 Timing Considerations 17 Typical Torque Versus Speed Curves M061 LE08 Series and Parallel 19 M062 LE08 Series and Parallel M063 LE08 Series 20 M063 L...

Страница 5: ...re doing any me chanical work CAUTION The SLO SYN SS2000MD4M O is designed for 24 to 40 Vdc input only see Section 4 2 Electrical Specifications Page 11 WARRANTY INFORMATION Reconfiguration of the cir...

Страница 6: ...cillator fails to operate properly Appendix A provides procedures for troubleshooting electrical interference problems 1 2 PRODUCT FEATURES The SLO SYN SS2000MD4M O Drive Oscillator combines a bipolar...

Страница 7: ...ntain case temperature below 70 C 158 F 3 Select the desired motor current at standstill 50 or 100 and set switch 6 as described in section 4 5 2 4 Select the appropriate run speed source on board tri...

Страница 8: ...it in place Do not use too much thermal compound It is better to use too little than too much Figure 3 1 Mounting Diagram NOTE Case temperature must not exceed 70 C 158 F When selecting a mounting loc...

Страница 9: ...age 7 3 2 TERMINAL LOCATIONS AND ASSIGNMENTS Figure 3 2 shows the terminal locations for the SLO SYN SS2000MD4M O Drive Oscillator Figure 3 2 Terminal Locations Motor and Power Supply Connector J2 I O...

Страница 10: ...nd M5 The motor frame must be grounded Cabling from the Drive Oscillator to the motor should be done with a shielded twisted pair cable The wires for each motor phase should be twisted together about...

Страница 11: ...LEAD MOTORS D F B H 5 4 1 3 GREEN WHITE RED RED 6 LEAD MOTORS WHITE N C E 2 G N C BLACK WHITE GREEN D F B H 5 4 1 3 WHITE BLACK WHITE RED RED 8 LEAD MOTORS SERIES CONNECTIONS G BLACK A WHITE ORANGE E...

Страница 12: ...nt and voltage parameters see list of components below It is recommended that the power supply leads be twisted together using approximately six twists per foot 0 3 m NOTES 1 The cable between the fil...

Страница 13: ...ooling may be required Storage 40 F to 167 F 40 C to 75 C Humidity 95 max noncondensing Altitude 10 000 feet 3048 m max 4 4 MOTOR COMPATIBILITY Motor Types Superior Slo Syn M and KM Series M Series Fr...

Страница 14: ...0 KML060F08 3 5 1 0 2 0 KML060F11 3 5 1 0 2 0 KML061F05 2 5 1 2 1 5 KML061F11 3 5 1 0 3 0 KML062F07 3 0 1 0 2 5 KML062F13 3 5 1 0 4 0 KML063F07 3 0 1 5 2 0 KML063F13 3 5 1 0 4 0 KML091F07 3 0 1 0 2 0...

Страница 15: ...ll OFF 1 0 1 1 5 2 2 0 3 2 5 4 3 0 5 3 5 4 5 2 Automatic Current Reduce Disable When switch 6 is in the OFF position the current at standstill goes to 50 of the selected level When switch 6 is in the...

Страница 16: ...nverted to digital form using an 8 bit A D This will result in granularity in the resolution settings The ranges of each p a rameter are specified in Full Steps sec and Full steps sec2 Parameter Descr...

Страница 17: ...d set speed AWO All Windings Off Input J1 4 When this signal is low AC and DC current to the motor will be zero Caution There will be no holding torque when the AWO signal is low GND Signal ground J1...

Страница 18: ...he LOW SPEED input is active the motor speed will stay at Low speed otherwise the speed is increased to the Run speed at the acceleration rate set via the ACCEL potentiometer When the RUN input is rem...

Страница 19: ...epict the timing relationships between the RUN in put motor speed and motor current Figure 4 3 Timing Considerations 50 ms 50 ms Run Input Low Speed MOTOR SPEED Run Speed Current Motor Speed with LOW...

Страница 20: ...abilities which may cause a loss of torque at step ping rates outside the range of natural resonance frequencies One such instability is broadly defined as mid range instability Usually the damping of...

Страница 21: ...SS2000MD4M O Page 19 5 2 TYPICAL TORQUE VERSUS SPEED CURVES NOTE The test conditions used when obtaining the torque versus speed data are listed in the lower left hand corner of each curve...

Страница 22: ...Page 20 SS2000MD4M O...

Страница 23: ...SS2000MD4M O Page 21...

Страница 24: ...Page 22 SS2000MD4M O...

Страница 25: ...SS2000MD4M O Page 23...

Страница 26: ...Page 24 SS2000MD4M O...

Страница 27: ...SS2000MD4M O Page 25...

Страница 28: ...Page 26 SS2000MD4M O...

Страница 29: ...lowing checklist will help in locating and correcting the problem In General Check all installation wiring carefully for wiring errors or poor connections Check to see that the proper voltage levels a...

Страница 30: ...er supply voltage IF FAULT INDICATOR IS LIT Check For Improper motor wiring Grounded or shorted wiring to the motor or shorted motor Improper motor type or incorrect Current Select switch setting If a...

Страница 31: ...onditioning such as line filters or isolation transformers 2 Be certain proper wiring practices are followed for location groun ding wiring and relay suppression It is highly suggested that twisted pa...