background image

28

IF TORQUE IS LOW, Check For:

All Windings Off active.

Correct current setting.

Improper supply voltage.

IF "FAULT" INDICATOR IS LIT, Check For:

Improper motor wiring

Grounded or shorted wiring to the motor or shorted motor

Improper motor type or incorrect Current Select switch setting

If a malfunction occurs that cannot be corrected by making the preceding
checks, contact Superior Electric.

Содержание SLO-SYN SS2000MD4-M

Страница 1: ...INSTALLATION INSTRUCTIONS for SLO SYN MODEL SS2000MD4 M MICROSTEP TRANSLATOR DRIVE...

Страница 2: ...PECIFICATIONS 11 4 1 Mechanical Specifications 11 4 2 Electrical Specifications 11 4 3 Environmental Specifications 11 4 4 Motor Compatibility 12 4 5 Current Settings 14 4 6 Automatic Current Reductio...

Страница 3: ...echanical work CAUTION This unit is designed for 24 to 40 Vdc input only see Section 4 2 Electrical Specifications Page 11 WARRANTY INFORMATION Reconfiguration of the circuit in any fashion not shown...

Страница 4: ...rocedures to follow if the Translator Drive fails to operate properly Appendix A provides procedures for troubleshooting electrical interference problems 1 2 PRODUCT FEATURES The SLO SYN SS2000MD4 M T...

Страница 5: ...efer to Section 4 4 for a list of compatible motors 2 Set the correct current level for the motor being used per the instruc tions in Section 4 5 Heat sinking may be required to maintain case temperat...

Страница 6: ...compound It is better to use too little than too much Figure 3 1 Mounting Diagram NOTE Case temperature must not exceed 70 C 158 F When selecting a mounting location it is important to leave at least...

Страница 7: ...2 TERMINAL LOCATIONS AND ASSIGNMENTS Figure 3 2 shows the terminal locations for the SLO SYN SS2000MD4 M Translator Drive I O Connector J1 Motor And Power Supply Connector J2 Figure 3 2 Terminal Locat...

Страница 8: ...e motor frame must be grounded Cabling from the drive to the motor should be done with a shielded twisted pair cable The wires for each motor phase should be twisted together about six times per foot...

Страница 9: ...ORS D F B H 5 4 1 3 GREEN WHITE RED RED 6 LEAD MOTORS WHITE N C E 2 G N C BLACK WHITE GREEN D F B H 5 4 1 3 WHITE BLACK WHITE RED RED 8 LEAD MOTORS SERIES CONNECTIONS G BLACK A WHITE ORANGE E GREEN C...

Страница 10: ...within three feet 0 9 meter of the input terminals The capacitor must be of the correct value and have the proper current and voltage parameters see list of components on page 11 It is recommended th...

Страница 11: ...ze Inches 1 56 H x 4 13 W x 3 25 D mm 40 H x 105 W x 83 D Weight 0 6 pounds 272 grams 4 2 ELECTRICAL SPECIFICATIONS DC Input Range 24 Vdc min 40 Vdc max DC Current see Motor Table Drive Power Dissipat...

Страница 12: ...umber of Connections 4 6 8 Minimum Inductance 0 5 millihenry Maximum Resistance 0 25 x Vdc Supply I Setting Example Vdc 30 I Setting 3 5 R max 0 25 x 30 3 5 2 1 ohms NOTE Maximum resistance is total o...

Страница 13: ...FO8 3 5 1 0 2 0 KML060F11 3 5 1 0 2 0 KML061FO5 2 5 1 2 1 5 KML061F11 3 5 1 0 3 0 KML062F07 3 0 1 0 2 5 KML062F13 3 5 1 0 4 0 KML063F07 3 0 1 5 2 0 KML063F13 3 5 1 0 4 0 KML091F07 3 0 1 0 2 0 KML091F1...

Страница 14: ...Current Position amperes None 1 0 1 1 5 2 2 0 3 2 5 4 3 0 5 3 5 4 6 AUTOMATIC CURRENT REDUCTION When switch 6 is in the OFF position the current at standstill goes to 50 of the selected level This oc...

Страница 15: ...evel And Step Resolution 4 8 SIGNAL SPECIFICATIONS 4 8 1 Terminal Assignments All connections are made via the 4 pin terminal strip J1 Pin Assignment 1 OPTO 2 PULSE 3 DIR 4 AWO 4 8 2 Signal Descriptio...

Страница 16: ...t When this signal is low AC and DC current to the motor will be zero Caution There will be no holding torque when the AWO signal is low NOTE If you are using the drive with an SS2000I or SS2000I V co...

Страница 17: ...e Figure 4 2 4 9 INDICATOR LIGHTS FAULT LED Red Lights to indicate over current condition This condition is caused by motor wiring errors or a ground fault Recovery from over current condition require...

Страница 18: ...eleration deceleration through the resonance areas aid in reducing instability to a level that provides smooth shaft velocity and accurate positioning If instability does cause unacceptable performanc...

Страница 19: ...VES NOTE The test conditions used when obtaining the torque versus speed data are listed in the lower left hand corner of each curve 1 10 MICROSTEP M061LE08 ETC MOTORS SERIES CONNECTED 1 10 MICROSTEP...

Страница 20: ...20 1 10 MICROSTEP M062LE09 ETC MOTORS SERIES CONNECTED 1 10 MICROSTEP M062LE09 ETC MOTORS PARALLEL CONNECTED 1 10 MICROSTEP M063LE09 ETC MOTORS SERIES CONNECTED...

Страница 21: ...21 1 10 MICROSTEP M063LE09 ETC MOTORS PARALLEL CONNECTED 1 10 MICROSTEP M091 FD8109 ETC MOTORS SERIES CONNECTED 1 10 MICROSTEP M091 FD8109 ETC MOTORS PARALLEL CONNECTED...

Страница 22: ...22 1 10 MICROSTEP M092 FD8109 ETC MOTORS SERIES CONNECTED 1 10 MICROSTEP M092 FD8109 ETC MOTORS PARALLEL CONNECTED...

Страница 23: ...23...

Страница 24: ...24...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...the problem In General Check all installation wiring carefully for wiring errors or poor connec tions Check to see that the proper voltage levels are being supplied to the unit Be sure that the motor...

Страница 28: ...voltage IF FAULT INDICATOR IS LIT Check For Improper motor wiring Grounded or shorted wiring to the motor or shorted motor Improper motor type or incorrect Current Select switch setting If a malfunct...

Страница 29: ...problems exist use appropriate line conditioning such as line filters or isolation transformers 2 Be certain proper wiring practices are followed for location groun ding wiring and relay suppression...

Страница 30: ...30 NOTES...

Страница 31: ...ed in any way which has been improperly installed or which has been subject to misuse neglect or accident THE FOREGOING WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT...

Страница 32: ...of the closest authorized distributor IN U S A AND CANADA 383 Middle Street Bristol CT 06010 Tel 860 585 4500 FAX 860 589 2136 Fax 1 800 766 6366 Customer Service 1 800 787 3532 Product Application 1...

Отзывы: