SECTION 2: EXPRESS START UP
PROCEDURE
The following instructions define the minimum steps necessary to make your
Drive
operational.
CAUTION
:
Always disconnect the power to the unit before connecting or discon-
necting the motor leads. FAILURE TO DO THIS WILL RESULT IN A
SHOCK HAZARD AND MAY DAMAGE THE DRIVE.
Always operate the unit with the Motor and the Drive enclosure
GROUNDED. Be sure to twist together the wires for each motor phase
as well as those for the dc input. Six twists per foot (0.3 m) is a good
guideline.
1.
Check to see that the motor used is compatible with the drive. Refer to
Section 4.4 for a list of compatible motors.
2.
Set the correct current level for the motor being used per the instruc-
tions in Section 4.5.
Heat sinking may be required to maintain case
temperature below +70° C (+158° F)
.
3.
Select the appropriate step resolution and set the switches as de-
scribed in Section 4.7.
4.
Wire the motor per the "Motor Connections" description in Section 3.2.
5.
Connect the power source to the DC input terminal strip. Be sure to
follow the instructions for connecting the filter capacitor as described
in Section 3.2, under Power Input.
NOTES:
If the motor operates erratically, refer to Section 5, "Torque
Versus Speed Characteristics".
Clockwise and counterclockwise directions are properly oriented
when viewing the motor from the end opposite the mounting
flange.